Consistency-based rectification of nonrigid registrations

Abstract. We present a technique to rectify nonrigid registrations by improving their group-wise consistency, which is a widely used unsupervised measure to assess pair-wise registration quality. While pair-wise registration methods cannot guarantee any group-wise consistency, group-wise approaches typically enforce perfect consistency by registering all images to a common reference. However, errors in individual registrations to the reference then propagate, distorting the mean and accumulating in the pair-wise registrations inferred via the reference. Furthermore, the assumption that perfect correspondences exist is not always true, e.g., for interpatient registration. The proposed consistency-based registration rectification (CBRR) method addresses these issues by minimizing the group-wise inconsistency of all pair-wise registrations using a regularized least-squares algorithm. The regularization controls the adherence to the original registration, which is additionally weighted by the local postregistration similarity. This allows CBRR to adaptively improve consistency while locally preserving accurate pair-wise registrations. We show that the resulting registrations are not only more consistent, but also have lower average transformation error when compared to known transformations in simulated data. On clinical data, we show improvements of up to 50% target registration error in breathing motion estimation from four-dimensional MRI and improvements in atlas-based segmentation quality of up to 65% in terms of mean surface distance in three-dimensional (3-D) CT. Such improvement was observed consistently using different registration algorithms, dimensionality (two-dimensional/3-D), and modalities (MRI/CT).

[1]  Brian B. Avants,et al.  Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain , 2008, Medical Image Anal..

[2]  Nicholas Ayache,et al.  Symmetric Log-Domain Diffeomorphic Registration: A Demons-Based Approach , 2008, MICCAI.

[3]  Benoit M. Dawant,et al.  Validation of a Nonrigid Registration Error Detection Algorithm Using Clinical MRI Brain Data , 2015, IEEE Transactions on Medical Imaging.

[4]  William M. Wells,et al.  Bayesian characterization of uncertainty in intra-subject non-rigid registration , 2013, Medical Image Anal..

[5]  Johan Montagnat,et al.  Performance Evaluation of Grid-Enabled Registration Algorithms Using Bronze-Standards , 2006, MICCAI.

[6]  Daniel Rueckert,et al.  Diffeomorphic Registration Using B-Splines , 2006, MICCAI.

[7]  B. M. Dawant,et al.  Estimation of Registration Accuracy Applied to Multi-Atlas Segmentation , 2011 .

[8]  Torsten Rohlfing,et al.  Image Similarity and Tissue Overlaps as Surrogates for Image Registration Accuracy: Widely Used but Unreliable , 2012, IEEE Transactions on Medical Imaging.

[9]  D. Robinson,et al.  Fundamental performance limits in image registration , 2004, Proceedings 2003 International Conference on Image Processing (Cat. No.03CH37429).

[10]  Andriy Myronenko,et al.  Intensity-Based Image Registration by Minimizing Residual Complexity , 2010, IEEE Transactions on Medical Imaging.

[11]  Gary E. Christensen,et al.  Consistent image registration , 2001, IEEE Transactions on Medical Imaging.

[12]  Sung Yong Shin,et al.  Scattered Data Interpolation with Multilevel B-Splines , 1997, IEEE Trans. Vis. Comput. Graph..

[13]  Stefan Klein,et al.  Groupwise image registration of multimodal head-and-neck images , 2015, 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI).

[14]  Benoit M. Dawant,et al.  Automatic Detection of the Magnitude and Spatial Location of Error in Non-rigid Registration , 2012, WBIR.

[15]  Gábor Székely,et al.  Investigating anisotropic diffusion for the registration of abdominal MR images , 2013, 2013 IEEE 10th International Symposium on Biomedical Imaging.

[16]  Scott T. Grafton,et al.  Automated image registration: I. General methods and intrasubject, intramodality validation. , 1998, Journal of computer assisted tomography.

[17]  Daniel Rueckert,et al.  Consistent groupwise non-rigid registration for atlas construction , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[18]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[19]  Gary E. Christensen,et al.  Invertibility and transitivity analysis for nonrigid image registration , 2003, J. Electronic Imaging.

[20]  Hemant D. Tagare,et al.  Symmetric and Transitive Registration of Image Sequences , 2008, Int. J. Biomed. Imaging.

[21]  Tom Vercauteren,et al.  Diffeomorphic demons: Efficient non-parametric image registration , 2009, NeuroImage.

[22]  Nassir Navab,et al.  Dense image registration through MRFs and efficient linear programming , 2008, Medical Image Anal..

[23]  Mark W. Woolrich,et al.  A Bayesian Approach for Spatially Adaptive Regularisation in Non-rigid Registration , 2013, MICCAI.

[24]  Gary E. Christensen,et al.  Transitive Inverse-Consistent Manifold Registration , 2005, IPMI.

[25]  Xiujuan Geng,et al.  Transitive inverse-consistent image registration and evaluation , 2007 .

[26]  P Boesiger,et al.  4D MR imaging of respiratory organ motion and its variability , 2007, Physics in medicine and biology.

[27]  David J. Hawkes,et al.  Automatic Estimation of Error in Voxel-Based Registration , 2004, MICCAI.

[28]  Josien P. W. Pluim,et al.  DIRBoost: An algorithm for boosting deformable image registration , 2012, 2012 9th IEEE International Symposium on Biomedical Imaging (ISBI).

[29]  Vladimir Petrovic,et al.  Non-Rigid Registration Assessment Without Ground Truth , 2006 .

[30]  Ying Wei,et al.  Evaluating Image Registration Using NIREP , 2010, WBIR.

[31]  J. Modersitzki,et al.  Ill-posed medicine—an introduction to image registration , 2008 .

[32]  Tobias Gass,et al.  Total Variation Regularization of Displacements in Parametric Image Registration , 2014, ABDI@MICCAI.

[33]  Tobias Gass,et al.  Estimation of atlas-based segmentation outcome: Leveraging information from unsegmented images , 2013, 2013 IEEE 10th International Symposium on Biomedical Imaging.

[34]  Lisa Tang,et al.  Improving Probabilistic Image Registration via Reinforcement Learning and Uncertainty Evaluation , 2013, MLMI.

[35]  Josien P. W. Pluim,et al.  Supervised quality assessment of medical image registration: Application to intra-patient CT lung registration , 2012, Medical Image Anal..

[36]  Lewis D. Griffin,et al.  Zen and the art of medical image registration: correspondence, homology, and quality , 2003, NeuroImage.

[37]  Tobias Gass,et al.  Detection and correction of inconsistency-based errors in non-rigid registration , 2014, Medical Imaging.

[38]  L. J. van Vliet,et al.  Detection of protrusions in curved folded surfaces applied to automated polyp detection in CT colonography , 2006 .

[39]  Xavier Pennec,et al.  A Framework for Uncertainty and Validation of 3-D Registration Methods Based on Points and Frames , 2004, International Journal of Computer Vision.

[40]  Nicholas Ayache,et al.  Iconic feature based nonrigid registration: the PASHA algorithm , 2003, Comput. Vis. Image Underst..

[41]  Jan Kybic,et al.  Bootstrap Resampling for Image Registration Uncertainty Estimation Without Ground Truth , 2010, IEEE Transactions on Image Processing.

[42]  Torsten Rohlfing,et al.  Quo Vadis, Atlas-Based Segmentation? , 2005 .

[43]  Hiroyuki Yoshida,et al.  Abdominal Imaging. Computational and Clinical Applications , 2014, Lecture Notes in Computer Science.

[44]  David J. Hawkes,et al.  Voxel similarity measures for 3-D serial MR brain image registration , 1999, IEEE Transactions on Medical Imaging.

[45]  Guido Gerig,et al.  Unbiased diffeomorphic atlas construction for computational anatomy , 2004, NeuroImage.