Research on modeling and fault analysis of permanent magnet operating mechanism of vacuum circuit breaker

In this paper, a kind of permanent magnet operating mechanism was modeled and studied by using ADAMS and Ansoft software, and the model was verified by experiments. Then, six common faults were chosen to do simulated analysis, and opening and closing process was divided into three stages according to its force analysis, respectively. The angle displacement of main axis, which related to the moving contact's displacement, was treated as the objective to study the performance of permanent magnet operating mechanism. When the research is combined with on-line monitoring technology, it can be used to guide fault diagnosis and condition prediction of vacuum circuit breaker.

[1]  Sung-Chin Hahn,et al.  Design optimization of permanent magnetic actuator for vacuum circuit breaker by response surface method , 2012, 2012 15th International Conference on Electrical Machines and Systems (ICEMS).

[2]  Wang Jun,et al.  Simulating Research on Fuzzy PID Control to Synchronous Closing Operation of Permanent-Magnet Vacuum Circuit Breaker , 2010, 2010 International Conference on Electrical and Control Engineering.

[3]  Juan Qiu,et al.  Research on Mechanical Fault Prediction Algorithm for Circuit Breaker Based on Sliding Time Window and ANN , 2008, IEICE Trans. Electron..

[4]  Li Haomin,et al.  Research on dynamic characteristics of permanent magnet brushless DC Motor operating mechanism in 126kV vacuum circuit breaker , 2013, 2013 2nd International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST).

[5]  Wu Yang,et al.  Mechanical condition recognition of medium-voltage vacuum circuit breaker based on mechanism dynamic features simulation and ANN , 2005 .

[6]  Wu Yang,et al.  Theoretical and experimental analyses of the mechanical characteristics of a medium-voltage circuit breaker , 2005 .

[7]  Lin Heyun,et al.  Magnetic Field Analysis and Control Strategy of Permanent Magnet Actuator for Low Voltage Vacuum Circuit Breaker , 2007, 2007 7th International Conference on Power Electronics and Drive Systems.

[8]  Hao Zhang,et al.  Development of integrated intelligent controlling for permanent magnetic operating mechanism , 2006 .

[9]  Mingzhe Rong,et al.  Condition monitoring of vacuum circuit breakers using vibration analysis , 2004, XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV..

[10]  Xin Lin,et al.  Experimental system research on permanent magnet motor operating mechanism of high voltage circuit breaker , 2011, 2011 International Conference on Electrical Machines and Systems.

[11]  Mingzhe Rong,et al.  Analyses of mechanical characteristics of vacuum circuit breaker during the closing process taking electrodynamic force into account , 2007 .

[12]  Lan Song,et al.  Static characteristic analysis and control technique of a new permanent magnetic operating mechanism , 2011, 2011 International Conference on Electric Information and Control Engineering.

[13]  Stephen McArthur,et al.  Design of trip current monitoring system for circuit breaker condition assessment , 2007 .