Generation of metaimages while analysis of the time series autoradiograms

To increase selectivity of activation autoradiography for the first time it has been suggested to use computer’s processing of time series of autoradiography images obtained while the sample is cooling. To preserve the spatial resolution of the method, the processing must involve all coaxial pixels of the series. For visualization of the obtained results a cross section method for generation of a set of metaimages has been developed. The generated metaimages characterize the spatial distribution of pixels for half-life values lying in the selected interval. The algorithm for testing the computational data compatibility within the preselected zone has been developed. The algorithm is based on analysis of frequency distribution of half-life values for pixels array composing the sample zone under testing. The normal distribution characterizes compatible data for homogeneous part of the sample. Using the frequency analysis, a method for generation of contrasted metaimages has been developed. The method is able to distinguish zones with half-life differences of about 1 h.

[1]  V. P. Kolotov,et al.  Determination of Platinum-Group Elements and Gold in Silicates by Gamma Activation Autoradiography and Instrumental Gamma Activation Analysis , 2003 .

[2]  Yu. A. Sapozhnikov,et al.  Alpha track analysis and fission track analysis for localizing actinide-bearing micro-particles in the Yenisey River bottom sediments , 2008 .

[3]  V. P. Kolotov,et al.  Determination of platinum-palladium micro inclusions in polymetallic ores by means of digital gamma-activation autoradiography , 2008 .

[4]  J. Furukawa Vanadium uptake and an effect of vanadium treatment on 18 F-labeled water movement in a cowpea plant by positron emitting tracer imaging system (PETIS) , 2001, Journal of Radioanalytical and Nuclear Chemistry.

[5]  G. Budd Techniques of Autoradiography.Andrew W. Rogers , 1968 .

[6]  T. Kume,et al.  A new visualization technique for the study of the accumulation of photoassimilates in wheat grains using [(11)C]CO(2). , 2006, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[7]  V. P. Kolotov,et al.  Development of digital gamma-activation autoradiography for the determination of platinum group element inclusions in geological samples , 2007 .

[8]  Yu. A. Sapozhnikov,et al.  Radiography and local microanalysis for detection and examination of actinide-containing microparticles , 2006 .

[9]  J. Noguchi,et al.  Imaging plate characteristics of positron emitters: 11C, 13N, 15O, 18F and 38K , 2001 .

[10]  R. Lindstrom,et al.  Radioactive particle analysis by digital autoradiography , 2001 .

[11]  V. P. Kolotov,et al.  Development of digital gamma-activation autoradiography for analysis of samples of large area , 2011 .

[12]  V. P. Kolotov,et al.  Enhancement of digital gamma activation autoradiography capabilities by means of computer analysis of the time series images , 2011, Journal of Radioanalytical and Nuclear Chemistry.

[13]  Hiroshi Uchida,et al.  Uptake and transport of positron-emitting tracer (18F) in plants☆ , 1997 .

[14]  S. E. Vinokurov,et al.  Low-temperature immobilization of actinides and other components of high-level waste in magnesium potassium phosphate matrices , 2009 .