Intracardiac ultrasound determination of left ventricular volumes: in vitro and in vivo validation.

OBJECTIVES This study was designed to assess the feasibility of calculating left ventricular volumes using intracardiac ultrasound. BACKGROUND Previous studies have validated transthoracic echocardiographic determinations of left ventricular volumes and have indicated the superiority of Simpson rule reconstruction algorithms. The feasibility of imaging the left ventricle with intracardiac ultrasound has also been demonstrated. METHODS The determination of left ventricular volumes with Simpson rule reconstruction of intracardiac ultrasound images was evaluated in two phases. In vitro validation was performed in 29 animal hearts preserved in either a nondistended or distended state. Latex cast volumes were the reference standard. In vivo studies used 14 pigs, and compared intracardiac ultrasound volumes and ejection fraction with single-plane contrast angiographic values. A 12.5-MHz device was used to record short-axis images at 0.5-cm intervals. These were used to reconstruct the ventricle as a stack of cylindric elements using all imaged levels as well as sections recorded every 1 and 2 cm and at a single midventricular level. RESULTS In the in vitro hearts, when all recorded sections were used, there was excellent agreement between intracardiac ultrasound and latex cast volumes (intracardiac ultrasound volume = 0.89 latex cast volume + 2.22, r = 0.95; intracardiac ultrasound volume = 0.97 latex cast volume + 0.91, r = 0.99) for nondistended and distended hearts, respectively. In vivo, there was again close correspondence between ultrasound and angiographic volumes (intracardiac ultrasound volume = 1.04 angiographic volume - 3.6, r = 0.91). The relation between intracardiac ultrasound and angiographic ejection fraction was fair (intracardiac ultrasound ejection fraction = 1.00 angiographic ejection fraction + 6.85, r = 0.69). Excellent correlations for the volumes were maintained as the number of cross sections was reduced to those recorded every 1 and 2 cm (r = 0.87 to 0.99). With a single midventricular site more variable but generally good correlations were obtained (r = 0.77 to 0.99). CONCLUSIONS The application of Simpson rule reconstruction to short-axis images of the left ventricle obtained with intracardiac ultrasound provides accurate determination of left ventricular volumes in animal hearts. This technique may prove useful in the analysis of left ventricular structure and function.

[1]  G A Diamond,et al.  Computer enhancement of direct and venous-injected left ventricular contrast angiography. , 1981, American heart journal.

[2]  N Reichek,et al.  Quantitation of Human Left Ventricular Mass and Volume by Two‐dimensional Echocardiography: In Vitro Anatomic Validation , 1981, Circulation.

[3]  M. Quiñones,et al.  Quantification of Left Ventricular Volumes by Two‐dimensional Echocardiograph: A Simplified and Accurate Approach , 1983, Circulation.

[4]  P. Guéret,et al.  Two‐dimensional Echocardiographic Quantitation of Left Ventricular Volumes and Ejection Fraction: Importance of Accounting for Dyssynergy in Short‐axis Reconstruction Models , 1980, Circulation.

[5]  D C Heilbron,et al.  Determination of Left Ventricular Volume in Children: Echocardiographic and Angiographic Comparisons , 1980, Circulation.

[6]  A. Weyman Cross-sectional echocardiography , 1982 .

[7]  P. Guéret,et al.  Cross-sectional Echocardiography: II. Analysis of Mathematic Models for Quantifying Volume of the Formalin-fixed Left Ventricle , 1980, Circulation.

[8]  J. Gault Angiographic estimation of left ventricular volume. , 1975, Catheterization and cardiovascular diagnosis.

[9]  C L Feldman,et al.  Assessment of Left Ventricular Ejection Fraction and Volumes by Real-time, Two-dimensional Echocardiography: A Comparison of Cineangiographic and Radionuclide Techniques , 1979, Circulation.

[10]  B. Brundage,et al.  Left Ventricular Volume from Paired Biplane Two‐dimensional Echocardiography , 1979, Circulation.

[11]  I. Bernstein Applied Multivariate Analysis , 1988 .

[12]  R. Engler,et al.  Measurement of Left Ventricular Ejection Fraction by Mechanical Cross-Sectional Echocardiography , 1979, Circulation.

[13]  J. W. Kennedy,et al.  Left ventricular volume and mass from single-plane cineangiocardiogram. A comparison of anteroposterior and right anterior oblique methods. , 1970, American heart journal.

[14]  R. O'rourke,et al.  Comparative Accuracy of Apical Biplane Cross‐sectional Echocardiography and Gated Equilibrium Radionuclide Angiography for Estimating Left Ventricular Size and Performance , 1981, Circulation.

[15]  J. Weiss,et al.  Accuracy of Volume Determination by Two‐dimensional Echocardiography: Defining Requirements Under Controlled Conditions in the Ejecting Canine Left Ventricle , 1983, Circulation.

[16]  L. Bentivoglio,et al.  Radiographic evaluation of formulas for left ventricular volume using canine casts. , 1972, Journal of applied physiology.

[17]  Steven E. Nissen,et al.  Intravascular Ultrasound Assessment of Lumen Size and Wall Morphology in Normal Subjects and Patients With Coronary Artery Disease , 1991, Circulation.

[18]  E. Corday,et al.  Assessment of quantitative methods for 2-dimensional echocardiography. , 1983, The American journal of cardiology.

[19]  P. Fitzgerald,et al.  Limitations of comparing left ventricular volumes by two dimensional echocardiography, myocardial markers and cineangiography. , 1982, The American journal of cardiology.

[20]  A J Tajik,et al.  Intravascular ultrasound imaging: in vitro validation and pathologic correlation. , 1990, Journal of the American College of Cardiology.

[21]  G. Maurer,et al.  Geometric accuracy of intravascular ultrasound imaging. , 1992, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[22]  J. Fleiss The design and analysis of clinical experiments , 1987 .

[23]  G. Marx,et al.  Intracardiac echocardiography in humans using a small-sized (6F), low frequency (12.5 MHz) ultrasound catheter. Methods, imaging planes and clinical experience. , 1993, Journal of the American College of Cardiology.

[24]  A. Shoukas,et al.  Accurate Volume Determination in the Isolated Ejecting Canine Left Ventricle by Two-dimensional Echocardiography , 1979, Circulation.