Biomaterials in Total Hip Joint Replacements: The Evolution of Basic Concepts, Trends, and Current Limitations—A Review
暂无分享,去创建一个
[1] P. S. Rama Sreekanth,et al. Assessment of bulk and surface properties of medical grade UHMWPE based nanocomposites using Nanoindentation and microtensile testing. , 2013, Journal of the mechanical behavior of biomedical materials.
[2] S. Kaloshkin,et al. Ultra-high molecular weight polyethylene reinforced with multi-walled carbon nanotubes: Fabrication method and properties , 2012 .
[3] Young-Hoo Kim,et al. Contemporary total hip arthroplasty with and without cement in patients with osteonecrosis of the femoral head: a concise follow-up, at an average of seventeen years, of a previous report. , 2011, The Journal of bone and joint surgery. American volume.
[4] M. Neo,et al. Bone bonding ability and handling properties of a titania-polymethylmethacrylate (PMMA) composite bioactive bone cement modified with a unique PMMA powder. , 2011, Acta biomaterialia.
[5] S. Knight,et al. Total Hip Arthroplasty - over 100 years of operative history , 2011, Orthopedic reviews.
[6] B. Espehaug,et al. Wear and migration of highly cross‐linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: A randomized radiostereometric study of 150 patients , 2011, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[7] J. Simões,et al. Enhanced UHMWPE Reinforced with MWCNT through Mechanical Ball-Milling , 2011 .
[8] W. Zhong,et al. Improved wear and mechanical properties of UHMWPE–carbon nanofiber composites through an optimized paraffin-assisted melt-mixing process , 2011 .
[9] T. Johnson,et al. Highly crosslinked polyethylene in posterior-stabilized total knee arthroplasty: in vitro performance evaluation of wear, delamination, and tibial post durability. , 2011, The Journal of arthroplasty.
[10] R. Brand,et al. Biographical Sketch: Themistocles Gluck (1853–1942) , 2011, Clinical orthopaedics and related research.
[11] P. Castell,et al. Effects of gamma-irradiation on UHMWPE/MWNT nanocomposites , 2011 .
[12] Y. Nien,et al. The mechanical study of acrylic bone cement reinforced with carbon nanotube , 2010 .
[13] W. Ortega-Lara,et al. Mechanical properties and apatite-forming ability of PMMA bone cements , 2009 .
[14] K. Takeda,et al. Effects of barium concentration on the radiopacity and biomechanics of bone cement: experimental study , 2008, Radiation Medicine.
[15] N. Nuño,et al. Measurement of transient and residual stresses during polymerization of bone cement for cemented hip implants. , 2008, Journal of biomechanics.
[16] P. Revell. Joint Replacement Technology , 2008 .
[17] A. Essner,et al. A highly crosslinked UHMWPE for CR and PS total knee arthroplasties. , 2008, The Journal of arthroplasty.
[18] Zhongmin Jin,et al. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. , 2008, Journal of biomechanics.
[19] O. Muratoglu,et al. Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications. , 2007, Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms.
[20] S. R. Bakshi,et al. Synthesis and characterization of multiwalled carbon nanotube reinforced ultra high molecular weight polyethylene composite by electrostatic spraying technique , 2007 .
[21] E. Gómez-Barrena,et al. Comparative fatigue behavior and toughness of remelted and annealed highly crosslinked polyethylenes. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.
[22] S. Mallapragada,et al. Effect of crosslinking and Pt–Zr quasicrystal fillers on the mechanical properties and wear resistance of UHMWPE for use in artificial joints , 2007 .
[23] S. Röhrl,et al. Very low wear of non-remelted highly cross-linked polyethylene cups: An RSA study lasting up to 6 years , 2007, Acta orthopaedica.
[24] G. Hallan. WEAR, FIXATION, AND REVISION OF TOTAL HIP PROSTHESES , 2007 .
[25] T. Blanchet,et al. The effect of pre-irradiation vacuum storage on the oxidation and wear of radiation sterilized UHMWPE , 2006 .
[26] Y. Leng,et al. Processing and mechanical properties of HA/UHMWPE nanocomposites. , 2006, Biomaterials.
[27] D. Schroeder,et al. Anisotropy and oxidative resistance of highly crosslinked UHMWPE after deformation processing by solid-state ram extrusion. , 2006, Biomaterials.
[28] R. Middleton,et al. Controversial topics in orthopaedics: ceramic-on-ceramic. , 2005, Annals of the Royal College of Surgeons of England.
[29] L. Dorr,et al. Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. , 2005, The Journal of bone and joint surgery. American volume.
[30] Aiguo Wang,et al. The clinical relevance of hip joint simulator testing: In vitro and in vivo comparisons , 2005 .
[31] Y. Leng,et al. Processing of hydroxyapatite reinforced ultrahigh molecular weight polyethylene for biomedical applications. , 2005, Biomaterials.
[32] Todd V Swanson,et al. The tapered press fit total hip arthroplasty: a European alternative. , 2005, The Journal of arthroplasty.
[33] P B Pynsent,et al. Birmingham hip resurfacing arthroplasty. A minimum follow-up of five years. , 2005, The Journal of bone and joint surgery. British volume.
[34] A.M.J.S. Vervest,et al. Zweymüller cementless total hip arthroplasty with two designs of titanium rectangular stem and a titanium threaded cup : a clinical, radiological and DEXA study , 2005 .
[35] J. Katz,et al. Early failures of total hip replacement: effect of surgeon volume. , 2004, Arthritis and rheumatism.
[36] A. Nogier,et al. Alumina Ceramic against Polyethylene: A long term follow up , 2004 .
[37] Tongxi Yu,et al. Toughening high performance ultrahigh molecular weight polyethylene using multiwalled carbon nanotubes , 2003 .
[38] A. Wang,et al. Ceramic femoral heads prevent runaway wear for highly crosslinked polyethylene acetabular cups by third-body bone cement particles , 2003 .
[39] Yunhai Ma,et al. Effects of the wollastonite fiber modification on the sliding wear behavior of the UHMWPE composites , 2003 .
[40] C P Tsui,et al. Wear performance of ultrahigh molecular weight polyethylene/quartz composites. , 2003, Biomaterials.
[41] D. Mcminn,et al. Development of metal/metal hip resurfacing. , 2003, Hip international : the journal of clinical and experimental research on hip pathology and therapy.
[42] S. G. Capps,et al. Why a Taper? , 2002, The Journal of bone and joint surgery. American volume.
[43] A. Edidin,et al. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. , 2002, The Journal of arthroplasty.
[44] Laurent Sedel,et al. Alumina-on-Alumina Total Hip Arthroplasty: A Minimum 18.5-Year Follow-up Study , 2002, The Journal of bone and joint surgery. American volume.
[45] T. Glant,et al. Osteolysis: basic science. , 2001, Clinical orthopaedics and related research.
[46] W H Harris,et al. Wear and periprosthetic osteolysis: the problem. , 2001, Clinical orthopaedics and related research.
[47] D. Farrar,et al. Rheological properties of PMMA bone cements during curing. , 2001, Biomaterials.
[48] K. Chiu,et al. Review Article: Polyethylene Wear and Osteolysis in Total Hip Arthroplasty , 2001, Journal of orthopaedic surgery.
[49] Y. Nho,et al. The effect of γ-irradiation on ultra-high molecular weight polyethylene recrystallized under different cooling conditions , 2001 .
[50] S. Al‐Malaika. Vitamin E: An effective biological antioxidant for polymer stabilisation , 2000 .
[51] C. Engh,et al. Factors affecting femoral bone remodeling after cementless total hip arthroplasty. , 1999, The Journal of arthroplasty.
[52] D. Sochart,et al. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. , 1999, Clinical orthopaedics and related research.
[53] John J. Callaghan,et al. Current Concepts Review - Wear in Total Hip and Knee Replacements* , 1999 .
[54] C. Doyle,et al. Plasma sprayed hydroxyapatite coatings on titanium substrates. Part 1: Mechanical properties and residual stress levels. , 1998, Biomaterials.
[55] L. Costa,et al. In vivo UHMWPE biodegradation of retrieved prosthesis. , 1998, Biomaterials.
[56] B. Espehaug,et al. Antibiotic prophylaxis in total hip arthroplasty , 1997 .
[57] E. Tsuji,et al. The optimum dose of gamma radiation–heavy doses to low wear polyethylene in total hip prostheses , 1997, Journal of materials science. Materials in medicine.
[58] Harlan C. Amstutz,et al. Metal on Metal Bearings in Hip Arthroplasty , 1996, Clinical orthopaedics and related research.
[59] C. Engh,et al. Wear of Polyethylene Cups in Total Hip Arthroplasty. A Study of Specimens Retrieved Post Mortem* , 1996, The Journal of bone and joint surgery. American volume.
[60] P. Campbell,et al. Metal versus polyethylene wear particles in total hip replacements. A review. , 1996, Clinical orthopaedics and related research.
[61] F. Shen,et al. Irradiation of chemically crosslinked ultrahigh molecular weight polyethylene , 1996 .
[62] J. Galante,et al. Wear Debris in Total Joint Replacements , 1994, The Journal of the American Academy of Orthopaedic Surgeons.
[63] J. Judet,et al. The use of an artificial femoral head for arthroplasty of the hip joint. , 1950, The Journal of bone and joint surgery. British volume.