Accurate DC Current Ratio Measurements for Primary Currents up to 600 A

A setup based on a direct current (dc) comparator, typically employed in high-current low-resistance calibrations, has been developed for the accurate calibration of dc current ratios for dc currents up to 600 A. For primary currents above 100 A, multiple turns of the primary conductor are made through the device under test. A full uncertainty analysis reveals that the 1 part in 106 total expanded uncertainty (k = 2) in a calibration of a zero-flux device is limited by the behavior of the device, in particular the instability and sensitivity to the position of the primary current conductor.

[1]  N. Kusters The Precise Measurement of Current Ratios , 1964 .

[2]  N. Kusters,et al.  A self-balancing direct current comparator for 20 000 amperes , 1965 .

[3]  N. Kusters,et al.  A Direct-Current-Comparator Ratio Bridge for Four-Terminal Resistance Measurements , 1966 .

[4]  N. Kusters,et al.  A Direct-Current-Comparator Bridge for Measuring Shunts up to 20000 Amperes , 1969 .

[5]  P. N. Miljanic,et al.  The Current Comparator , 1988 .

[6]  J.M. Williams,et al.  A cryogenic current comparator bridge for resistance measurements at currents of up to 100 A , 1998, 1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254).

[7]  Gunnar Fernqvist,et al.  Design and verification of a 24 kA calibration head for a DCCT test facility [LHC current control] , 1999, IEEE Trans. Instrum. Meas..

[8]  R. Rudervall,et al.  High Voltage Direct Current ( HVDC ) Transmission Systems Technology Review Paper , 2000 .

[9]  Gunnar Fernqvist,et al.  A novel current calibration system up to 20 kA , 2003, IEEE Trans. Instrum. Meas..

[10]  G. Hudson,et al.  4-13 kA DC current transducers enabling accurate in-situ calibration for a new particle accelerator project, LHC , 2005, 2005 European Conference on Power Electronics and Applications.

[11]  M. Kraft Measurement Techniques of Low-Value High-Current Single-Range Current Shunts from 15 Amps to 3000 Amps , 2006 .

[12]  Gert Rietveld,et al.  Automated Low-Ohmic Resistance Measurements at the $\mu \Omega/\Omega$ Level , 2007, IEEE Transactions on Instrumentation and Measurement.

[13]  B. Jeckelmann,et al.  Comparison of CERN and metas high current standards up to 10kA , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[14]  J. Williams Cryogenic current comparators and their application to electrical metrology , 2011 .

[15]  Gert Rietveld,et al.  Low-Ohmic Resistance Comparison: Measurement Capabilities and Resistor Traveling Behavior , 2013, IEEE Transactions on Instrumentation and Measurement.

[16]  Haiming Shao,et al.  DC 5 kA Current Ratio Standards Based on Series–Parallel Self-Calibration DCCs , 2013, IEEE Transactions on Instrumentation and Measurement.

[17]  G. Rietveld,et al.  Accurate high-current DC current ratio measurements , 2014, 29th Conference on Precision Electromagnetic Measurements (CPEM 2014).

[18]  E. So,et al.  The establishment of high current DC shunt calibration system at KRISS and comparison with NRC , 2014, 29th Conference on Precision Electromagnetic Measurements (CPEM 2014).

[19]  Gunnar Fernqvist,et al.  High accuracy current measurement in the main power converters of the large hadron collider: tutorial 53 , 2014, IEEE Instrumentation & Measurement Magazine.

[20]  L. Callegaro,et al.  On the Calibration of Direct-Current Current Transformers (DCCT) , 2014, IEEE Transactions on Instrumentation and Measurement.