Thermal evaluation of a chair with fans as an individually controlled system

It is difficult for a total air-conditioning system to satisfy the thermal comfort of all workers in an office. Therefore, an individually controlled system that can create a comfortable thermal environment for each worker is needed. In the present study, two chairs incorporating two fans each, one under the seat and one behind the backrest, were developed to provide isothermal forced airflow to the chair occupant. The chairs differed in the size of the fans. Experiments were conducted in a climate chamber during the summer. Seven subjects, who were healthy male college students, were allowed to freely control the two built-in fans by adjusting dials on the accompanying desk. The room air temperatures were set at 26 °C, 28 °C, 30 °C and 32 °C. The following findings were obtained. At a room air temperature of 28 °C, the whole-body thermal sensations were almost thermally neutral, regardless of the type of chair. At a room air temperature of 30 °C, the occupants were able to create acceptable thermal environments from the viewpoints of whole-body thermal sensation and comfort by using the chairs with fans. Their local discomfort rates at the back and lower back, which were affected by the isothermal airflows, were greatly improved at this room air temperature. However, at a room air temperature of 32 °C, the chairs tested in the present study were not able to provide acceptable thermal environments. In order to provide a more comfortable environment to the chair occupants, additional local systems to cool the head, arms, and hands are needed.

[1]  Hui Zhang,et al.  Partial- and whole-body thermal sensation and comfort— Part I: Uniform environmental conditions , 2006 .

[2]  Leslie E. Sparks,et al.  Fundamental Mass Transfer Model for Indoor Air Emissions from Surface Coatings , 1993 .

[3]  A. Melikov,et al.  Human response to local heating for use in connection with low enthalpy ventilation , 1998 .

[4]  A. Melikov,et al.  The influence of heated or cooled seats on the acceptable ambient temperature range , 2007, Ergonomics.

[5]  Fred Bauman,et al.  Field study of the impact of a desktop task/ambient conditioning system in office buildings , 1998 .

[6]  Povl Ole Fanger,et al.  Human Response to Five Designs of Personalized Ventilation , 2006 .

[7]  P. Fanger,et al.  Human response to personalized ventilation and mixing ventilation. , 2004, Indoor air.

[8]  Arsen Krikor Melikov,et al.  Human Response to an Individually Controlled Microenvironment , 2007 .

[9]  A. Melikov Personalized ventilation. , 2004, Indoor air.

[10]  Shinichi Tanabe,et al.  THERMAL COMFORT OF TASK AIR CONDITIONING WITH ISOTHERMAL AIR FLOW UNIT , 2004 .

[11]  Fred Bauman,et al.  Localized comfort control with a desktop task conditioning system: laboratory and field measurements , 1993 .

[12]  Hui Zhang,et al.  Testing of Localized Ventilation Systems in a New Controlled Environment Chamber , 1991 .

[13]  M.G.L.C. Loomans Study on the applicability of the desk replacement ventilation concept , 1999 .

[14]  Arsen Krikor Melikov,et al.  Personalized ventilation: air terminal devices with high efficiency , 2003 .

[15]  Kexin Li,et al.  EXPERIMENTAL ANALYSIS IN INDOOR THERMAL ENVIRONMENT IN TASK AND AMBIENT AIR-CONDITIONING SYSTEM USING STAND-ALONE PERSONAL HEAT PUMP UNIT , 1994 .

[16]  Hui Zhang,et al.  Testing and optimizing the performance of a floor-based task conditioning system , 1995 .

[17]  S. Tanabe,et al.  Impact of Non-Isothermal Task Conditioning System on Thermal Comfort , 2003 .

[18]  Arsen Krikor Melikov,et al.  S-105 Evaluation of an Individually Controlled Environment by Means of a Breathing hermal Manikin , 2005 .

[19]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[20]  Fred Bauman,et al.  Individual thermal comfort control with desk-mounted and floor-mounted task/ambient conditioning (TAC) systems , 1999 .