Volumetric modulation arc radiotherapy with flattening filter-free beams compared with static gantry IMRT and 3D conformal radiotherapy for advanced esophageal cancer: a feasibility study.

PURPOSE A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). METHODS AND MATERIALS The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving ≥ 95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving ≥ 5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. RESULTS RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 ± 0.1 for RA and IMRT and 1.5 ± 0.2 for 3D-CRT. The mean lung dose was 12.2 ± 4.5 for IMRT, 11.3 ± 4.6 for RA, and 10.8 ± 4.4 for RA with FFF beams, 18.2 ± 8.5 for 3D-CRT. The percentage of volume receiving ≥ 20 Gy ranged from 23.6% ± 9.1% to 21.1% ± 9.7% for IMRT and RA (FFF beams) and 39.2% ± 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 ± 139, 322 ± 20, and 387 ± 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a ∼20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds). CONCLUSION RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

[1]  M. Scorsetti,et al.  Open Access , 2003 .

[2]  Jeff Z. Y. Chen,et al.  Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT & Arc technique for esophageal carcinoma. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  André Wambersie,et al.  The International Commission on Radiation Units and Measurements , 2001, Journal of the ICRU.

[4]  J. Bedford,et al.  Volumetric modulated arc therapy planning for distal oesophageal malignancies. , 2012, The British journal of radiology.

[5]  Stephen Breen,et al.  Dosimetric comparison of IMRT vs. 3D conformal radiotherapy in the treatment of cancer of the cervical esophagus. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  R. Ginsberg,et al.  INT 0123 (Radiation Therapy Oncology Group 94-05) phase III trial of combined-modality therapy for esophageal cancer: high-dose versus standard-dose radiation therapy. , 2002, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[7]  Charles S Mayo,et al.  Hybrid IMRT for treatment of cancers of the lung and esophagus. , 2008, International journal of radiation oncology, biology, physics.

[8]  Joe Y. Chang,et al.  Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  J. Cooper,et al.  Combined chemotherapy and radiotherapy compared with radiotherapy alone in patients with cancer of the esophagus. , 1992, The New England journal of medicine.

[10]  S. Senan,et al.  Radiological and clinical pneumonitis after stereotactic lung radiotherapy: a matched analysis of three-dimensional conformal and volumetric-modulated arc therapy techniques. , 2011, International journal of radiation oncology, biology, physics.

[11]  Yong Yin,et al.  Applications of IMAT in cervical esophageal cancer radiotherapy: a comparison with fixed‐field IMRT in dosimetry and implementation , 2011, Journal of applied clinical medical physics.

[12]  Tommy Knöös,et al.  Current status and future perspective of flattening filter free photon beams. , 2011, Medical physics.

[13]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[14]  L. Cozzi,et al.  Pre-clinical evaluation of respiratory-gated delivery of volumetric modulated arc therapy with RapidArc , 2010, Physics in medicine and biology.

[15]  L. Cozzi,et al.  Predicted risk of radiation-induced cancers after involved field and involved node radiotherapy with or without intensity modulation for early-stage hodgkin lymphoma in female patients. , 2010, International journal of radiation oncology, biology, physics.

[16]  W. Ulmer,et al.  A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations , 2005, Physics in medicine and biology.

[17]  L. Cozzi,et al.  Involved-node and involved-field volumetric modulated arc vs. fixed beam intensity-modulated radiotherapy for female patients with early-stage supra-diaphragmatic Hodgkin lymphoma: a comparative planning study. , 2009, International journal of radiation oncology, biology, physics.

[18]  N Hodapp,et al.  [The ICRU Report 83: prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)]. , 2012, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al].

[19]  Matthew B Podgorsak,et al.  Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer. , 2011, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[20]  Yi-Jen Chen,et al.  Helical tomotherapy for radiotherapy in esophageal cancer: a preferred plan with better conformal target coverage and more homogeneous dose distribution. , 2007, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[21]  Jan Hrbacek,et al.  Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm. , 2011, International journal of radiation oncology, biology, physics.

[22]  Radhe Mohan,et al.  Stereotactic radiotherapy for lung cancer using a flattening filter free Clinac , 2009, Journal of applied clinical medical physics.

[23]  J. Fraumeni,et al.  Rising incidence of adenocarcinoma of the esophagus and gastric cardia. , 1991, JAMA.

[24]  Jason Cashmore,et al.  Lowering whole-body radiation doses in pediatric intensity-modulated radiotherapy through the use of unflattened photon beams. , 2011, International journal of radiation oncology, biology, physics.

[25]  Luca Cozzi,et al.  A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.