Impedance characterization and modelling of an improved patch clamp device

The gold standard for studying the properties of ion channels is the patch clamp, a technique that measures pA currents passing through ion channels in an isolated patch of cell membrane. The authors sought to design an improved device for whole-cell patch clamp recordings using nanoscale pipettes which more readily form seals with the cell membrane and a movable metal electrode to decrease the access resistance, increase the signal bandwidth, and clear debris from the pipette tip. Electrical characterization of the instrument by impedance spectroscopy showed that advancing the metal electrode towards the pipette tip decreased the impedance distinctly in different frequency bands, the greatest decrease occurring between 1 and 100 kHz, and the smallest at 100 kHz. Finite element simulations of the electrode, incorporating the electrode/electrolyte interface, suggest that optimal signal transmission can be achieved with athick-walled pipette, nearly filled with alarge Ag/AgCl electrode, whose impedance can be reduced through surface modification.

[1]  A Shrier,et al.  Series resistance compensation for whole-cell patch-clamp studies using a membrane state estimator. , 1999, Biophysical journal.

[2]  D. Worley,et al.  New technique for reducing the impedance of silver-silver chloride electrodes , 1983, Medical and Biological Engineering and Computing.

[3]  J. Jersch,et al.  New etching procedure for silver scanning tunneling microscopy tips , 1996 .

[4]  Y. J. Kingma,et al.  Improved Ag/AgCl pressure electrodes , 1983, Medical and Biological Engineering and Computing.

[5]  F. Crenner,et al.  Ag/AgCl electrode assembly for thin smooth muscle electromyography , 1989, Medical and Biological Engineering and Computing.

[6]  Yan Zhao,et al.  Patch clamp technique: Review of the current state of the art and potential contributions from nanoengineering , 2008 .

[7]  S. Lockery,et al.  Pressure polishing: a method for re-shaping patch pipettes during fire polishing , 2000, Journal of Neuroscience Methods.

[8]  H. Helmholtz,et al.  Studien über electrische Grenzschichten , 1879 .

[9]  J. Rae,et al.  Constructing a patch clamp setup. , 1992, Methods in enzymology.

[10]  G. Pucihar,et al.  Numerical Determination of Transmembrane Voltage Induced on Irregularly Shaped Cells , 2006, Annals of Biomedical Engineering.

[11]  J. Randles Kinetics of rapid electrode reactions , 1947 .

[12]  B. Sakmann,et al.  Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches , 1981, Pflügers Archiv.

[13]  Bert Sakmann,et al.  Geometric parameters of pipettes and membrane patches , 1983 .

[14]  L. E. Baker,et al.  Optimum electrolytic chloriding of silver electrodes , 2006, Medical and biological engineering.

[15]  A. Stogryn,et al.  Equations for Calculating the Dielectric Constant of Saline Water (Correspondence) , 1971 .

[16]  R A Levis,et al.  Glass technology for patch clamp electrodes. , 1992, Methods in enzymology.

[17]  Stephen F Traynelis,et al.  Software-based correction of single compartment series resistance errors , 1998, Journal of Neuroscience Methods.

[18]  Harald Sontheimer,et al.  2 Whole-Cell Patch-Clamp Recordings , 2007 .

[19]  E. Warburg,et al.  Ueber das Verhalten sogenannter unpolarisirbarer Elektroden gegen Wechselstrom , 1899 .

[20]  R. Penner A Practical Guide to Patch Clamping , 1995 .

[21]  Yan Zhao,et al.  A Novel Way to Go Whole Cell in Patch-Clamp Experiments , 2010, IEEE Transactions on Biomedical Engineering.

[22]  R A Levis,et al.  The use of quartz patch pipettes for low noise single channel recording. , 1993, Biophysical journal.