Coordinated Control Approaches for Low-Voltage Ride-Through Enhancement in Wind Turbines With Doubly Fed Induction Generators

This paper deals with the coordinated control of rotor- and grid-side converters in wind turbines with doubly fed induction generators (DFIGs) to improve the low-voltage ride-through capability. The rotor-side converter control and additional equipment, called stator damping resistor, are used to limit the rotor inrush current and to reduce the oscillations and settling time of DFIG transient response during the voltage dip. Also, the grid-side converter is controlled to limit the dc-link overvoltage during the voltage drop. It is found that the dynamics of the grid-side converter and dc-link voltage exhibit nonminimum phase behavior, and thus there is an inherent limitation on the achievable dynamic response during the fault. Since the dc-link dynamics is nonlinear, the linear control scheme cannot properly limit the dc-link voltage under large voltage dips. Thus, a nonlinear control scheme applied to the grid-side converter is proposed, which stabilizes the internal dynamics and limits the dc-link voltage fluctuations during the fault. The proposed ride-through approaches limit the peak values of rotor current and dc-link voltage at the instants of occurring and clearing the fault. They also limit the oscillations of electromagnetic torque, and consequently, improve the DFIG voltage dip behavior.

[1]  A. Keyhani,et al.  IGSPICE Simulation of Induction Machines with Saturable Inductances , 1989, IEEE Power Engineering Review.

[2]  Ehab F. El-Saadany,et al.  An improved fault ride-through strategy for doubly fed induction generator-based wind turbines , 2008 .

[3]  Katsuhiko Ogata,et al.  Modern Control Engineering , 1970 .

[4]  P. Sanchis,et al.  Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips , 2007, IEEE Transactions on Energy Conversion.

[5]  Peter W. Lehn,et al.  Experimental evaluation of STATCOM closed loop dynamics , 1998 .

[6]  G. Joos,et al.  Short-term energy storage for wind energy applications , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[7]  T. Thiringer,et al.  Evaluation of current control methods for wind turbines using doubly-fed induction machines , 2005, IEEE Transactions on Power Electronics.

[8]  Peter Tavner,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006 .

[9]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[10]  Wei Zhang,et al.  Modeling and control of a wind-turbine-driven DFIG incorporating core saturation during grid voltage dips , 2008, 2008 International Conference on Electrical Machines and Systems.

[11]  Anca Daniela Hansen,et al.  Fault ride-through capability of DFIG wind turbines , 2007 .

[12]  A. Mullane,et al.  Wind-turbine fault ride-through enhancement , 2005, IEEE Transactions on Power Systems.

[13]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[14]  J. F. Conroy,et al.  Low-voltage ride-through of a full converter wind turbine with permanent magnet generator , 2007 .

[15]  Mohsen Rahimi,et al.  Transient Performance Improvement of Wind Turbines With Doubly Fed Induction Generators Using Nonlinear Control Strategy , 2010, IEEE Transactions on Energy Conversion.

[16]  Mike Barnes,et al.  Stability of doubly-fed induction generator under stator voltage orientated vector control , 2008 .

[17]  G. Venkataramanan,et al.  A Fault Tolerant Doubly Fed Induction Generator Wind Turbine Using a Parallel Grid Side Rectifier and Series Grid Side Converter , 2008, IEEE Transactions on Power Electronics.

[18]  J. F. Conroy,et al.  Aggregate modelling of wind farms containing full-converter wind turbine generators with permanent magnet synchronous machines: transient stability studies , 2009 .

[19]  Yongdong Li,et al.  Improved Crowbar Control Strategy of DFIG Based Wind Turbines for Grid Fault Ride-Through , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[20]  Fredrik Carlsson Saturation in synchronous machines due to voltage sags , 2003, IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03..

[21]  P. Ledesma,et al.  Doubly fed induction generator model for transient stability analysis , 2005, IEEE Transactions on Energy Conversion.

[22]  Mohsen Rahimi,et al.  Grid-fault ride-through analysis and control of wind turbines with doubly fed induction generators , 2010 .

[23]  Katsuhiko Ogata,et al.  Modern control engineering (3rd ed.) , 1996 .

[24]  Mike Barnes,et al.  Specification of rotor side voltage source inverter of a doubly-fed induction generator for achieving ride-through capability , 2008 .

[25]  Hui Li,et al.  An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator , 2008, IEEE Transactions on Power Electronics.

[26]  Ge Wang,et al.  Development of low voltage ride-through control strategy for wind power generation using real time digital simulator , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[27]  Wei Li,et al.  Power Electronic Converter Control Techniques for Improved Low Voltage Ride Through Performance in WTGs , 2006 .

[28]  T. Thiringer,et al.  Modeling and experimental verification of grid interaction of a DFIG wind turbine , 2005, IEEE Transactions on Energy Conversion.