Accuracy of electroencephalographic dipole localization of epileptiform activities associated with focal brain lesions

We evaluated the accuracy of an electroencephalographic (EEG) localization technique (dipole inverse solution) in a consecutive series of 12 focal intracerebral lesions of divrse etiologies whose EEGs showed interictal spike activity or rhythmic activity at seizure onset. The calculated equivalent dipole was plotted on three axes in the patients' magnetic resonance image, and the distance between the dipole and the lesion margin was measured assuming that the shell of the lesion constituted an epileptognic region. In all cases the dipole localized closer than 0.8 cm to the nearest lesion margin. In addition, we compared the postsurgical outcome of 6 patients to the dipole localization and the resection margins. In all 6 patients in whom the dipole, and hence the estimated seizure generator, was removed the surgical outcome was favorable. We conclude that the inverse solution algorithm is a promising method for using the scalp EEG to localize the sources of electrical activity in the human brain in routine clinical electroencephalography and provides three‐dimensional data not available from conventional analysis.

[1]  C D Binnie,et al.  Origin and propagation of interictal discharges in the acute electrocorticogram. Implications for pathophysiology and surgical treatment of temporal lobe epilepsy. , 1997, Brain : a journal of neurology.

[2]  S. Sato,et al.  Dipole localization in patients with epilepsy using the realistically shaped head model. , 1997, Electroencephalography and clinical neurophysiology.

[3]  A. Friedman,et al.  Predictors of Outcome of Epilepsy Surgery: Multivariate Analysis with Validation , 1996, Epilepsia.

[4]  S. Spencer Long‐Term Outcome After Epilepsy Surgery , 1996, Epilepsia.

[5]  G Lantz,et al.  Simultaneous intracranial and extracranial recording of interictal epileptiform activity in patients with drug resistant partial epilepsy: patterns of conduction and results from dipole reconstructions. , 1996, Electroencephalography and clinical neurophysiology.

[6]  C. Jack,et al.  Routine EEG and Temporal Lobe Epilepsy: Relation to Long‐Term EEG Monitoring, Quantitative MRI, and Operative Outcome , 1996, Epilepsia.

[7]  G. Cosgrove,et al.  Accuracy of EEG dipole localization using implanted sources in the human brain , 1996, NeuroImage.

[8]  C. Jack,et al.  Electrocorticography and Temporal Lobe Epilepsy: Relationship to Quantitative MRI and Operative Outcome , 1995, Epilepsia.

[9]  T A Pedley,et al.  Propagation patterns of temporal spikes. , 1995, Electroencephalography and clinical neurophysiology.

[10]  N Nakasato,et al.  Comparisons of MEG, EEG, and ECoG source localization in neocortical partial epilepsy in humans. , 1994, Electroencephalography and clinical neurophysiology.

[11]  C. N. Guy,et al.  Intracerebral propagation of interictal activity in partial epilepsy: implications for source localisation. , 1994, Journal of neurology, neurosurgery, and psychiatry.

[12]  Jerome Engel,et al.  Outcome with respect to epileptic seizures. , 1993 .

[13]  K. K. Tan,et al.  The spatial location of EEG electrodes: locating the best-fitting sphere relative to cortical anatomy. , 1993, Electroencephalography and clinical neurophysiology.

[14]  C. Jack,et al.  Determination of 10-20 system electrode locations using magnetic resonance image scanning with markers. , 1993, Electroencephalography and clinical neurophysiology.

[15]  P Jayakar,et al.  Localization of Seizure Foci: Pitfalls and Caveats , 1991, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[16]  J S Ebersole,et al.  Spike voltage topography identifies two types of frontotemporal epileptic foci , 1991, Neurology.

[17]  I. Fried,et al.  Intracranial, Intraaxial, Space‐Occupying Lesions in Patients with Intractable Partial Seizures: An Anatomoclinical, Neuropsychological, and Surgical Correlation , 1991, Epilepsia.

[18]  Kazutomo Yunokuchi,et al.  Tests of EEG localization accuracy using implanted sources in the human brain , 1991, Annals of neurology.

[19]  D. Cohen,et al.  MEG versus EEG localization test using implanted sources in the human brain , 1990, Annals of neurology.

[20]  J. Mazziotta,et al.  Presurgical evaluation for partial epilepsy , 1990, Neurology.

[21]  B. Neil Cuffin,et al.  Effects of Measurement Errors and Noise on MEG Moving Dipole Inverse Solutions , 1986, IEEE Transactions on Biomedical Engineering.

[22]  R D Sidman,et al.  A reliable method for localizing deep intracranial sources of the EEG , 1985, Neurology.

[23]  B. N. Cuffin,et al.  A Comparison of Moving Dipole Inverse Solutions Using EEG's and MEG's , 1985, IEEE Transactions on Biomedical Engineering.

[24]  P Gloor,et al.  Neuronal Generators and the Problem of Localization in Electroencephalography: Application of Volume Conductor Theory to Electroencephalography , 1985, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[25]  M. Scherg,et al.  Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model. , 1985, Electroencephalography and clinical neurophysiology.

[26]  J Beatty,et al.  Neuromagnetic evidence of spatially distributed sources underlying epileptiform spikes in the human brain. , 1984, Science.

[27]  D. Cohen,et al.  Comparison of the magnetoencephalogram and electroencephalogram. , 1979, Electroencephalography and clinical neurophysiology.

[28]  Allan H. Ropper,et al.  A Practical Non-Cephalic Reference Electrode: The Stephenson-Gibbs Non-Cephalic System , 1978 .

[29]  M R Schneider,et al.  A multistage process for computing virtual dipolar sources of EEG discharges from surface information. , 1972, IEEE transactions on bio-medical engineering.

[30]  W. Walter,et al.  COMPARISON OF SUBCORTICAL, CORTICAL AND SCALP ACTIVITY USING CHRONICALLY INDWELLING ELECTRODES IN MAN. , 1965, Electroencephalography and clinical neurophysiology.