3D printed brachytherapy jig for Reference Air Kerma Rate calibration

3D printing in modern radiotherapy allows users the ability to create custom devices which can be a valuable tool for use in brachytherapy source calibration. Radiotherapy centres may verify their brachytherapy source activity with a calibrated Farmer chamber. For this purpose, a jig was designed, 3D printed and commissioned for in-air source strength calibration. Measurements on four afterloaders with varied equipment and environments were completed. A full uncertainty budget was developed and measurements with the in-air jig were consistently within 3% of the certificate source strength, and within the 4.1% combined uncertainty for comparing a well chamber measurement (1.7%) with the in air jig (3.75%). By creating a jig that is able to be customised to multiple catheter sizes and cylindrical chamber designs, centres can be provided with the option of independently checking their source strength with ease and for little cost.

[1]  Ryan L. Smith,et al.  HDR brachytherapy well chamber calibration and stability evaluated over twenty years of clinical use. , 2020, Brachytherapy.

[2]  I. Kolkman-Deurloo,et al.  Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty. , 2004, Medical physics.

[3]  EPSM 2017, Engineering and Physical Sciences in Medicine , 2017, Australasian Physical & Engineering Sciences in Medicine.

[4]  Joel Nothman,et al.  SciPy 1.0-Fundamental Algorithms for Scientific Computing in Python , 2019, ArXiv.

[5]  Sarah Bassi,et al.  End-to-end dosimetric audit: A novel procedure developed for Irish HDR brachytherapy centres. , 2020, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[6]  Shwetha Bondel,et al.  Calibration of (192)Ir high dose rate brachytherapy source using different calibration procedures. , 2014, Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology.

[7]  T. Kairn,et al.  Quasi-simultaneous 3D printing of muscle-, lung- and bone-equivalent media: a proof-of-concept study , 2020, Physical and Engineering Sciences in Medicine.

[8]  Stephen V. Musolino,et al.  Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water; Technical Reports Series No. 398, , 2001 .

[9]  M. Ravikumar,et al.  Determination of contributions of scatter and distance error to the source strength of 192Ir HDR brachytherapy source , 2016 .

[10]  Ernesto Mainegra-Hing,et al.  On the accuracy of techniques for obtaining the calibration coefficient NK of Ir192 HDR brachytherapy sources. , 2006, Medical physics.

[11]  Larry A DeWerd,et al.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO. , 2011, Medical physics.

[12]  C Kolotas,et al.  Comparison of calibration procedures for 192Ir high-dose-rate brachytherapy sources. , 1999, International journal of radiation oncology, biology, physics.

[13]  M. L. Randolph,et al.  EFFECT OF FINITE SIZE OF IONIZATION CHAMBERS ON MEASUREMENTS OF SMALL PHOTON SOURCES , 1960 .

[14]  Annette Haworth,et al.  ACPSEM brachytherapy working group recommendations for quality assurance in brachytherapy , 2013, Australasian Physical & Engineering Sciences in Medicine.

[15]  A. Haworth,et al.  Comparison of192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement , 2008, Australasian Physics & Engineering Sciences in Medicine.

[16]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[17]  Thorsten Sander,et al.  Comparison of air kerma standards of LNE–LNHB and NPL for 192Ir HDR brachytherapy sources: EUROMET project no 814 , 2008, Physics in medicine and biology.

[18]  Antonio G. González,et al.  A Practical Way to ISO/GUM Measurement Uncertainty for Analytical Assays Including In-House Validation Data , 2017, Quality Control in Laboratory.

[19]  Narayan Prasad Patel,et al.  In-air calibration of an HDR 192Ir brachytherapy source using therapy ion chambers. , 2005, Journal of cancer research and therapeutics.

[20]  N. Patel,et al.  The non-uniformity correction factor for the cylindrical ionization chambers in dosimetry of an HDR 192Ir brachytherapy source , 2006, Journal of medical physics.

[21]  R. Wilks,et al.  PO-0227 Verification measurements for brachytherapy reference data , 2021 .

[22]  A technique for calibrating a high dose rate 192Ir brachytherapy source , 2012, Australasian Physical & Engineering Sciences in Medicine.

[23]  Scott E. Hudson,et al.  Understanding Uncertainty in Measurement and Accommodating its Impact in 3D Modeling and Printing , 2017, Conference on Designing Interactive Systems.

[24]  M. J. Rossiter,et al.  AIR KERMA RATE CALIBRATION OF SMALL SOURCES OF 60CO, 137CS, 226RA AND 192IR , 1991 .

[25]  Y. S. Mayya,et al.  A simplified analytical approach to estimate the parameters required for strength determination of HDR 192Ir brachytherapy sources using a Farmer-type ionization chamber. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[26]  Samuel C Peet,et al.  Dosimetric evaluation of a patient-specific 3D-printed oral positioning stent for head-and-neck radiotherapy , 2021, Physical and Engineering Sciences in Medicine.

[27]  J. Palta,et al.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. , 1994, Medical physics.

[29]  Yi-Chun Du,et al.  Room scatter factor modelling and measurement error analysis of 192Ir HDR calibration by a Farmer chamber. , 2007, Physics in medicine and biology.

[30]  A. Bielajew An analytic theory of the point-source nonuniformity correction factor for thick-walled ionisation chambers in photon beams , 1990 .

[31]  Tsair-Fwu Lee,et al.  Ir-192 Calibration in Air with Farmer Chamber for HDR Brachytherapy , 2016, Journal of medical and biological engineering.

[32]  Robin Hill Reporting uncertainties in measurement: what approach should be followed? , 2013, Australasian Physical & Engineering Sciences in Medicine.