Twenty-four-hour urinary trace element excretion: reference intervals and interpretive issues

Background Introduction of inductively coupled plasma mass spectrometry (ICP-MS) into clinical laboratories has led to an increasing application of analyses to risk assessment for toxicity from environmental exposure to trace elements, and in occupational monitoring. Interpretation of results from random urine samples may be problematic and measurement of excretion over 24 h is sometimes preferable. Recent reference data are sparse. Methods Twenty-four-hour urine samples from 111 healthy adults from the renal stones clinic in Southampton, UK, were analysed for 31 trace elements using ICP-MS and for zinc using atomic absorption spectroscopy. Non-parametric 0.95 coverage intervals were determined for trace element excretion per 24 h and as a ratio to creatinine, for the full study cohort and separately for men (n = 77) and women (n = 34). Results Beryllium was undetectable in 95% of samples, bismuth in 87% and uranium in 75%. In comparison with published ranges, reference intervals for this cohort were higher for molybdenum, tin and vanadium, and for arsenic due to inclusion of fish arsenicals. Aluminium, chromium, iron, lead and mercury were lower. In our cohort, 24-h excretion of 17 elements was significantly higher in men than in women. However, when expressed as trace element to creatinine ratios, the situation reversed strikingly. Because of their lower creatinine excretion, ratios for 18 elements were significantly higher for women. Conclusions New adult reference intervals were obtained for 24-h urine trace element excretion. Trace element:creatinine ratios must be used cautiously, with separate ranges for men and women.

[1]  F Cibella,et al.  Concentration and reference interval of trace elements in human hair from students living in Palermo, Sicily (Italy). , 2011, Environmental toxicology and pharmacology.

[2]  Marcin Słojewski,et al.  Major and trace elements in lithogenesis , 2011, Central European journal of urology.

[3]  M. Mularczyk-Oliwa,et al.  Magnesium, Calcium, and Trace Elements Excretion in 24-h Urine , 2011, Biological Trace Element Research.

[4]  S. Cho Calculation and Application of Partial Charges , 2010 .

[5]  L. Barregard,et al.  The influence of urinary flow rate on mercury excretion in children. , 2010, Journal of trace elements in medicine and biology : organ of the Society for Minerals and Trace Elements.

[6]  K. Kostial,et al.  Comparison of calcium, magnesium, sodium, potassium, zinc, and creatinine concentration in 24-h and spot urine samples in women , 2009, Clinical chemistry and laboratory medicine.

[7]  F. Barbosa,et al.  Reference concentrations for trace elements in urine for the Brazilian population based on q-ICP-MS with a simple dilute-and-shoot procedure , 2009 .

[8]  R. Sothern,et al.  Circadian characteristics of serum calcium, magnesium and eight trace elements and of their metallo-moieties in urine of healthy middle-aged men. , 2008, La Clinica terapeutica.

[9]  M. Óvári,et al.  Reference concentrations of trace elements in urine of the budapestian population , 2004, Biological Trace Element Research.

[10]  M. Óvári,et al.  Selected urinary metal reference concentrations of the Viennese population - urinary metal reference values (Vienna). , 2006, Journal of trace elements in medicine and biology : organ of the Society for Minerals and Trace Elements.

[11]  M. Černá,et al.  Blood and urine levels of Pb, Cd and Hg in the general population of the Czech Republic and proposed reference values. , 2006, International journal of hygiene and environmental health.

[12]  M. Ikeda,et al.  Reference values for cobalt, copper, manganese, and nickel in urine among women of the general population in Japan , 2006, International archives of occupational and environmental health.

[13]  P. Heitland,et al.  Biomonitoring of 30 trace elements in urine of children and adults by ICP-MS. , 2006, Clinica chimica acta; international journal of clinical chemistry.

[14]  U. Ewers,et al.  Revised and new reference values for some trace elements in blood and urine for human biomonitoring in environmental medicine. , 2004, International journal of hygiene and environmental health.

[15]  J. Blatny,et al.  Determination of normal concentration levels of Cd, Pb, Hg, Cu, Zn and Se in urine of the population in the Czech Republic. , 2002, Central European journal of public health.

[16]  K. Ash,et al.  Comparison of representative ranges based on U.S. patient population and literature reference intervals for urinary trace elements. , 2000, Clinica chimica acta; international journal of clinical chemistry.

[17]  B. Nygaard,et al.  Age- and sex-adjusted iodine/creatinine ratio. A new standard in epidemiological surveys? Evaluation of three different estimates of iodine excretion based on casual urine samples and comparison to 24 h values , 2000, European Journal of Clinical Nutrition.

[18]  B. Bocca,et al.  Reference values for chromium, nickel and vanadium in urine of youngsters from the urban area of Rome. , 2000, Journal of environmental monitoring : JEM.

[19]  L. Ovesen,et al.  Day-to-day and within-day variation in urinary iodine excretion , 1999, European Journal of Clinical Nutrition.

[20]  P. Walker,et al.  Use of gold as a routine and long term preservative for mercury in potable water, as determined by ICP-MS , 1999 .

[21]  H. Delves,et al.  Determination of total selenium in serum, whole blood and erythrocytes by ICP-MS , 1999 .

[22]  G. Iyengar Reevaluation of the trace element content in Reference Man , 1998 .

[23]  E. Sabbioni,et al.  Trace element reference values in tissues from inhabitants of the European Union. X. A study of 13 elements in blood and urine of a United Kingdom population. , 1998, The Science of the total environment.

[24]  R. Jackson,et al.  Trace metals in urine of United States residents: reference range concentrations. , 1998, Environmental research.

[25]  J. M. Christensen,et al.  Inductively coupled plasma mass spectrometric determination of molybdenum in urine from a Danish population. , 1998, The Analyst.

[26]  J. M. Christensen,et al.  Toxic trace element reference levels in blood and urine: influence of gender and lifestyle factors. , 1997, The Science of the total environment.

[27]  J. M. Christensen,et al.  Calculation and application of coverage intervals for biological reference values (Technical Report) , 1997 .

[28]  J. Angerer,et al.  The determination of metals (antimony, bismuth, lead, cadmium, mercury, palladium, platinum, tellurium, thallium, tin and tungsten) in urine samples by inductively coupled plasma-mass spectrometry , 1997, International archives of occupational and environmental health.

[29]  J. Bonham,et al.  Determination of antimony in urine, blood and serum and in liver and lung tissues of infants by inductively coupled plasma mass spectrometry. , 1997, The Analyst.

[30]  M. A. Packer,et al.  An evaluation of urinary measures of iodine and selenium status. , 1996, Journal of trace elements in medicine and biology : organ of the Society for Minerals and Trace Elements.

[31]  E. I. Hamilton,et al.  Element reference values in tissues from inhabitants of the European Community. VI. Review of elements in blood, plasma and urine and a critical evaluation of reference values for the United Kingdom population. , 1994, The Science of the total environment.

[32]  J. Versieck,et al.  Use of inductively coupled plasma mass spectrometry for the determination of ultra-trace elements in human serum , 1994 .

[33]  N. Konno,et al.  Clinical evaluation of the iodide/creatinine ratio of casual urine samples as an index of daily iodide excretion in a population study. , 1993, Endocrine journal.

[34]  C. Minoia,et al.  Trace element reference values in tissues from inhabitants of the European Community. II. Examples of strategy adopted and trace element analysis of blood, lymph nodes and cerebrospinal fluid of Italian subjects. , 1992, The Science of the total environment.

[35]  J. Hofbauer,et al.  Trace elements and urinary stone formation: new aspects of the pathological mechanism of urinary stone formation. , 1991, The Journal of urology.

[36]  P Apostoli,et al.  Trace element reference values in tissues from inhabitants of the European community. I. A study of 46 elements in urine, blood and serum of Italian subjects. , 1990, The Science of the total environment.

[37]  R. Levine,et al.  Urinary creatinine excretion is not stable: a new method for assessing urinary toxic substance concentrations. , 1989, Journal of occupational medicine. : official publication of the Industrial Medical Association.

[38]  J. Woittiez,et al.  Trace elements in human clinical specimens: evaluation of literature data to identify reference values. , 1988, Clinical chemistry.

[39]  L. Fidanza,et al.  Biological monitoring and chronobiology: preliminary time-quantified reference values of urinary zinc. , 1987, Chronobiologia.

[40]  H E Solberg,et al.  The theory of reference values Part 5. Statistical treatment of collected reference values. Determination of reference limits. , 1983, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie.

[41]  S K MacFarlane,et al.  Measurement of trace elements in urine. , 1976, Proceedings of the Royal Society of Medicine.