Impact of dwelling characteristics on concentrations of bacteria, fungi, endotoxin and total inflammatory potential in settled dust

Abstract Indoor air in homes contains a variety of organic agents such as bacteria, endotoxin and fungi. Epidemiological studies have shown links between these components and respiratory problems and the development of allergies. Twenty-eight dwellings located in the Greater Copenhagen area in Denmark were investigated in this study. Temperature, relative humidity and air exchange rate were measured. Dwelling characteristics including floor area, volume of the living room, floor material, year of construction of buildings and floor level were collected. The microbial exposure was measured by quantifying fungi, bacteria and endotoxin concentration in airborne dust collected by Electrostatic Dust fall Collectors (EDCs). The Total Inflammatory Potential (TIP) of the dust was also measured. Significantly higher concentrations of fungi were found in dwellings with high relative humidity (p = 0.03), larger room volume (p = 0.03) and in dwellings located on the second floor or higher (p = 0.02). Small floor area per person and low air exchange rate were significantly associated with increased concentrations of bacteria (both p  In conclusion, people living in smaller dwellings or in dwellings on upper floors are at higher risk of microbial exposure. While TIP was affected by some dwelling characteristics, it was mainly influenced by season.

[1]  H. Wichmann,et al.  Predictors of high endotoxin concentrations in the settled dust of German homes. , 2002, Indoor Air: International Journal of Indoor Environment and Health.

[2]  Nicolas Kalogerakis,et al.  Indoor air quality—bioaerosol measurements in domestic and office premises , 2005 .

[3]  W W Nazaroff,et al.  Size-resolved emission rates of airborne bacteria and fungi in an occupied classroom , 2012, Indoor air.

[4]  K. Ley,et al.  Homeostatic Regulation of Blood Neutrophil Counts , 2008, The Journal of Immunology.

[5]  A. Bertron,et al.  A review of indoor microbial growth across building materials and sampling and analysis methods , 2014 .

[6]  L. Morawska,et al.  WHO guidelines for indoor air quality: dampness and mould , 2009 .

[7]  Vidas K. Paulius,et al.  Indoor air quality in a middle school, Part II: Development of emission factors for particulate matter and bioaerosols. , 2000, Applied occupational and environmental hygiene.

[8]  James F. Meadow,et al.  Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source , 2013, Indoor air.

[9]  S. Wenzel,et al.  Bronchoscopic evaluation of severe asthma. Persistent inflammation associated with high dose glucocorticoids. , 1997, American journal of respiratory and critical care medicine.

[10]  T. Reponen,et al.  Exposure matrices of endotoxin, (1→3)-β-d-glucan, fungi, and dust mite allergens in flood-affected homes of New Orleans. , 2010, The Science of the total environment.

[11]  T. Meklin,et al.  Size distributions of airborne microbes in moisture-damaged and reference school buildings of two construction types , 2002 .

[12]  T. Halstensen,et al.  Upper airway inflammation in waste handlers exposed to bioaerosols , 2003, Occupational and environmental medicine.

[13]  I. Momas,et al.  Indoor airborne endotoxin assessment in homes of Paris newborn babies. , 2008, Indoor air.

[14]  L. Palmberg,et al.  House dust induces IL-6 and IL-8 response in A549 epithelial cells. , 1999, Indoor air.

[15]  D. Mav,et al.  Predictors of Endotoxin Levels in U.S. Housing , 2008, Environmental health perspectives.

[16]  Miia Pitkäranta,et al.  Diversity and seasonal dynamics of bacterial community in indoor environment , 2008, BMC Microbiology.

[17]  Tiina Reponen,et al.  Comparison of concentrations and size distributions of fungal spores in buildings with and without mould problems , 1994 .

[18]  A. Madsen,et al.  Inflammatory potency of dust from the indoor environment and correlation to content of NAGase and fungi. , 2006, Toxicology in vitro : an international journal published in association with BIBRA.

[19]  Michael Brauer,et al.  Evaluation and Determinants of Airborne Bacterial Concentrations in School Classrooms , 2004, Journal of occupational and environmental hygiene.

[20]  A. Wardlaw,et al.  Fungal allergy in asthma–state of the art and research needs , 2014, Clinical and Translational Allergy.

[21]  H. Wichmann,et al.  House dust endotoxin and allergic sensitization in children. , 2002, American journal of respiratory and critical care medicine.

[22]  L. Hildemann,et al.  Size-Resolved Concentrations of Particulate Matter and Bioaerosols Inside versus Outside of Homes , 2009 .

[23]  Mary-Louise McLaws,et al.  The role of particle size in aerosolised pathogen transmission: A review , 2010, Journal of Infection.

[24]  D. Nowak,et al.  Acute blood neutrophilia induced by short-term compost dust exposure in previously unexposed healthy individuals , 2006, International archives of occupational and environmental health.

[25]  Christopher Chang,et al.  Indoor air quality and human health , 2004, Clinical reviews in allergy & immunology.

[26]  J. Bousquet,et al.  Eosinophilic inflammation in asthma. , 1990, The New England journal of medicine.

[27]  A. Madsen,et al.  Assessment of the Total Inflammatory Potential of Bioaerosols by Using a Granulocyte Assay , 2009, Applied and Environmental Microbiology.

[28]  S. Collins,et al.  Induction of differentiation of the human promyelocytic leukemia cell line (HL-60) by retinoic acid. , 1980, Proceedings of the National Academy of Sciences of the United States of America.

[29]  Gabriel Bekö,et al.  Seasonal Variations of Indoor Microbial Exposures and Their Relation to Temperature, Relative Humidity, and Air Exchange Rate , 2012, Applied and Environmental Microbiology.

[30]  Gabriel Reboux,et al.  Characteristics of dwellings contaminated by moulds. , 2008, Journal of environmental monitoring : JEM.

[31]  D. Spiegelman,et al.  Home Endotoxin Exposure and Wheeze in Infants: Correction for Bias Due to Exposure Measurement Error , 2005, Environmental health perspectives.

[32]  R. Balasubramanian,et al.  Airborne bacteria, fungi, and endotoxin levels in residential microenvironments: a case study , 2012, Aerobiologia.

[33]  Frederick Fung,et al.  Health effects of indoor fungal bioaerosol exposure. , 2003, Applied occupational and environmental hygiene.

[34]  A. Madsen,et al.  Effect of relative humidity on the aerosolization and total inflammatory potential of fungal particles from dust-inoculated gypsum boards. , 2014, Indoor air.

[35]  Y. Sibille,et al.  Pulmonary immune cells in health and disease: polymorphonuclear neutrophils. , 1993, The European respiratory journal.

[36]  C. Bornehag,et al.  Building characteristics associated with moisture related problems in 8,918 Swedish dwellings , 2009, International journal of environmental health research.

[37]  L. Hildemann,et al.  The effects of human activities on exposure to particulate matter and bioaerosols in residential homes. , 2009, Environmental science & technology.

[38]  Steffen Loft,et al.  Evaluation of building characteristics in 27 dwellings in Denmark and the effect of using particle filtration units on PM2.5 concentrations , 2014 .

[39]  Lidia Morawska,et al.  Endotoxins in indoor air and settled dust in primary schools in a subtropical climate. , 2013, Environmental science & technology.

[40]  J Sundell,et al.  Dampness in buildings and health (DBH): Report from an ongoing epidemiological investigation on the association between indoor environmental factors and health effects among children in Sweden. , 2004, Indoor air.

[41]  Rajasekhar Balasubramanian,et al.  Assessment of airborne bacteria and fungi in food courts , 2011 .

[42]  D. Denning,et al.  The link between fungi and severe asthma: a summary of the evidence , 2006, European Respiratory Journal.

[43]  A. Pringle Asthma and the Diversity of Fungal Spores in Air , 2013, PLoS pathogens.

[44]  A. Hyvärinen,et al.  Moisture damage and childhood asthma: a population-based incident case–control study , 2007, European Respiratory Journal.

[45]  D. Dockery,et al.  Within-Home versus Between-Home Variability of House Dust Endotoxin in a Birth Cohort , 2005, Environmental health perspectives.

[46]  M. Bracken,et al.  The relation between fungal propagules in indoor air and home characteristics , 2001, Allergy.

[47]  A. Hyvärinen,et al.  Production of proinflammatory mediators by indoor air bacteria and fungal spores in mouse and human cell lines. , 2003, Environmental health perspectives.

[48]  G. Hobbs,et al.  Health effects of exposure to water-damaged New Orleans homes six months after Hurricanes Katrina and Rita. , 2008, American journal of public health.

[49]  A. Madsen,et al.  Sampling, extraction and measurement of bacteria, endotoxin, fungi and inflammatory potential of settling indoor dust. , 2012, Journal of environmental monitoring : JEM.

[50]  G. Handal,et al.  Children symptoms before and after knowing about an indoor fungal contamination. , 2004, Indoor air.

[51]  Ahmet Asan,et al.  Indoor and outdoor airborne bacteria in child day-care centers in Edirne City (Turkey), seasonal distribution and influence of meteorological factors , 2010, Environmental monitoring and assessment.

[52]  Bert Brunekreef,et al.  Evaluation of a Low-Cost Electrostatic Dust Fall Collector for Indoor Air Endotoxin Exposure Assessment , 2008, Applied and Environmental Microbiology.

[53]  D. Hamilos Allergic fungal rhinitis and rhinosinusitis. , 2010, Proceedings of the American Thoracic Society.

[54]  C. Persson Con: mice are not a good model of human airway disease. , 2002, American journal of respiratory and critical care medicine.

[55]  Tiina Reponen,et al.  Normal Range Criteria for Indoor Air Bacteria and Fungal Spores in a Subarctic Climate , 1992 .

[56]  A. Madsen,et al.  Comparison of sampling methods for the assessment of indoor microbial exposure. , 2012, Indoor air.

[57]  D. Gold,et al.  Home Characteristics as Predictors of Bacterial and Fungal Microbial Biomarkers in House Dust , 2010, Environmental health perspectives.

[58]  S. Collins,et al.  Continuous growth and differentiation of human myeloid leukaemic cells in suspension culture , 1977, Nature.

[59]  A. Madsen,et al.  Airborne Fungal and Bacterial Components in PM1 Dust from Biofuel Plants , 2009, The Annals of occupational hygiene.

[60]  J. Heinrich,et al.  Association between domestic mould and mould components, and asthma and allergy in children: a systematic review , 2011, European Respiratory Journal.