Cross-laminated timber panels (X-Lam panels) are evaluated for structural applications in Service Classes 1 and 2 conditions. The structural application in Service Class 3 conditions is not allowed, mainly because of (1) the high moisture content expected in timber and (2) some concerns related to the potential change in panels’ size when significant moisture changes happen. High moisture contents in X-Lam panels are not advisable, because it will lead to high level of stresses in glue lines. Several European Technical Approvals state the insignificance of the dimensional variations of X-Lam panels due to moisture content variation; however, according to other technical documents, this kind of variation should be accounted for. X-Lam panels are widely used across Europe, but their generalized use in Portugal has just started. The Portuguese first large project was completed in spring 2012: a sports center with a 25 m-long indoor swimming-pool and a gym. Given this non-conventional use of X-Lam panels, a monitoring program was started when construction was completed. The monitoring program aims to evaluate the performance of X-Lam panels in places where high environmental humidity is expected. The major parameters monitored are (1) wood moisture content, to ensure that the X-Lam panels are in Service Classes 1 and 2 conditions and (2) the dimensional stability of the panels, to ensure that no unforeseen stresses will develop in the structure. From the monitoring results already available, it is clear that the X-Lam panels are in Service Class 2 conditions without relevant dimensional variations.
[1]
Klaus Richter,et al.
Influence of wood moisture content on bending and shear stiffness of cross laminated timber panels
,
2011,
European Journal of Wood and Wood Products.
[2]
Ario Ceccotti,et al.
New Technologies for Construction of Medium-Rise Buildings in Seismic Regions: The XLAM Case
,
2008
.
[3]
Johan Jönsson,et al.
Internal stresses in the cross-grain direction in glulam induced by climate variations
,
2004
.
[4]
Chanakya Arya,et al.
Design in timber to BS 5268
,
2009
.
[5]
Martin Teibinger.
Urban Timber Houses in Vienna
,
2008
.
[6]
H. J. Larsen,et al.
DS/ENV 1995-1-1 NAD National Application Document for Eurocode 5: Design of Timber Structures, Part 1-1: General Rules and Rules for Buildings
,
1994
.
[7]
Robert J. Ross,et al.
Wood handbook : wood as an engineering material
,
2010
.
[8]
Martin Häglund,et al.
Varying moisture content and eigen-stresses in timber elements
,
2008
.
[9]
Stefania Fortino,et al.
Moisture-induced stresses perpendicular to grain in cross-sections of timber members exposed to different climates
,
2011
.
[10]
Luís Jorge,et al.
X-Lam Panels in Swimming-Pool Building – Monitoring the Environment and the Performance
,
2013
.
[11]
Kjell Arne Malo,et al.
The effect of climate variations on glulam—an experimental study
,
2012,
European Journal of Wood and Wood Products.