Orbitrap mass spectrometry with resolving powers above 1,000,000

Experiments on a modified Orbitrap Elite™ instrument have shown that Orbitrap™ technology is capable of resolving power in excess of 1,000,000 when appropriate tolerance and tuning requirements are met. Such levels are achieved for m/z < 300–400 within a 3 s detection time which makes it compatible with several types of chromatographic separations. It was shown that resolving powers over 500,000–1,000,000 allow resolution of fine isotopic structure and direct identification of some important post-translational modifications of peptides.

[1]  Alexander Makarov,et al.  Performance evaluation of a high-field orbitrap mass analyzer , 2009, Journal of the American Society for Mass Spectrometry.

[2]  Alan G. Marshall,et al.  ADVANTAGES OF HIGH MAGNETIC FIELD FOR FOURIER TRANSFORM ION CYCLOTRON RESONANCE MASS SPECTROMETRY , 1996 .

[3]  A. Makarov Theory and Practice of the Orbitrap Mass Analyzer , 2010 .

[4]  I. Chernushevich,et al.  An introduction to quadrupole-time-of-flight mass spectrometry. , 2001, Journal of mass spectrometry : JMS.

[5]  A. Marshall,et al.  Phase correction for collision model analysis and enhanced resolving power of fourier transform ion cyclotron resonance mass spectra. , 1999, Analytical chemistry.

[6]  A. Marshall,et al.  Fourier Transform Ion Cyclotron Resonance Spectroscopy , 1974 .

[7]  A. Marshall,et al.  Fourier transform ion cyclotron resonance mass spectrometry: a primer. , 1998, Mass spectrometry reviews.

[8]  Makarov,et al.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis , 2000, Analytical chemistry.

[9]  A. Makarov,et al.  Dynamics of ions of intact proteins in the Orbitrap mass analyzer , 2009, Journal of the American Society for Mass Spectrometry.

[10]  A. Makarov,et al.  The Orbitrap: a new mass spectrometer. , 2005, Journal of mass spectrometry : JMS.

[11]  B. A. Mamyrin Time-of-flight mass spectrometry (concepts, achievements, and prospects) , 2001 .

[12]  M. Gorshkov,et al.  Dynamics of ion motion in an elongated cylindrical cell of an ICR spectrometer and the shape of the signal registered , 1985 .

[13]  M. Mann,et al.  Parts per Million Mass Accuracy on an Orbitrap Mass Spectrometer via Lock Mass Injection into a C-trap*S , 2005, Molecular & Cellular Proteomics.

[14]  M. Mann,et al.  Ultra High Resolution Linear Ion Trap Orbitrap Mass Spectrometer (Orbitrap Elite) Facilitates Top Down LC MS/MS and Versatile Peptide Fragmentation Modes* , 2011, Molecular & Cellular Proteomics.

[15]  A. Makarov,et al.  Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer. , 2006, Analytical chemistry.

[16]  Scott A. Busby,et al.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications. , 2004, Journal of proteome research.