Reduction of susceptibility-induced signal losses in multi-gradient-echo images: Application to improved visualization of the subthalamic nucleus

T2-weighted gradient echo (GE) images yield good contrast of iron-rich structures like the subthalamic nuclei due to microscopic susceptibility induced field gradients, providing landmarks for the exact placement of deep brain stimulation electrodes in Parkinson's disease treatment. An additional advantage is the low radio frequency (RF) exposure of GE sequences. However, T2-weighted images are also sensitive to macroscopic field inhomogeneities, resulting in signal losses, in particular in orbitofrontal and temporal brain areas, limiting anatomical information from these areas. In this work, an image correction method for multi-echo GE data based on evaluation of phase information for field gradient mapping is presented and tested in vivo on a 3 Tesla whole body MR scanner. In a first step, theoretical signal losses are calculated from the gradient maps and a pixelwise image intensity correction is performed. In a second step, intensity corrected images acquired at different echo times TE are combined using optimized weighting factors: in areas not affected by macroscopic field inhomogeneities, data acquired at long TE are weighted more strongly to achieve the contrast required. For large field gradients, data acquired at short TE are favored to avoid signal losses. When compared to the original data sets acquired at different TE and the respective intensity corrected data sets, the resulting combined data sets feature reduced signal losses in areas with major field gradients, while intensity profiles and a contrast-to-noise (CNR) analysis between subthalamic nucleus, red nucleus and the surrounding white matter demonstrate good contrast in deep brain areas.

[1]  Didier Dormont,et al.  Is the subthalamic nucleus hypointense on T2-weighted images? A correlation study using MR imaging and stereotactic atlas data. , 2004, AJNR. American journal of neuroradiology.

[2]  K V Slavin,et al.  Direct visualization of the human subthalamic nucleus with 3T MR imaging. , 2006, AJNR. American journal of neuroradiology.

[3]  D. Norris,et al.  BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: Parallel‐acquired inhomogeneity‐desensitized fMRI , 2006, Magnetic resonance in medicine.

[4]  A Hemmingsson,et al.  Measurements of Magnetic Field Variations in the Human Brain Using a 3D‐FT Multiple Gradient Echo Technique , 1995, Magnetic resonance in medicine.

[5]  Tarek A. Yousry,et al.  A Quick and Universal Method for Stereotactic Visualization of the Subthalamic Nucleus before and after Implantation of Deep Brain Stimulation Electrodes , 2004, Stereotactic and Functional Neurosurgery.

[6]  R Turner,et al.  Optimized EPI for fMRI studies of the orbitofrontal cortex , 2003, NeuroImage.

[7]  Ewald Moser,et al.  Robust field map generation using a triple‐echo acquisition , 2004, Journal of magnetic resonance imaging : JMRI.

[8]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[9]  Abdelhamid Benazzouz,et al.  Imaging of subthalamic nucleus and ventralis intermedius of the thalamus , 2002, Movement disorders : official journal of the Movement Disorder Society.

[10]  T. Schaeffter,et al.  Limits of detection of SPIO at 3.0 T using T2* relaxometry , 2005, Magnetic resonance in medicine.

[11]  P. Dechent,et al.  Improved Visibility of the Subthalamic Nucleus on High-Resolution Stereotactic MR Imaging by Added Susceptibility (T2*) Contrast Using Multiple Gradient Echoes , 2007, American Journal of Neuroradiology.

[12]  P. Starr,et al.  Implantation of deep brain stimulators into the subthalamic nucleus: technical approach and magnetic resonance imaging-verified lead locations. , 2002, Journal of neurosurgery.

[13]  E. McVeigh,et al.  Signal‐to‐noise measurements in magnitude images from NMR phased arrays , 1997 .

[14]  Christine Preibisch,et al.  Exponential excitation pulses for improved water content mapping in the presence of background gradients , 2008, Magnetic resonance in medicine.

[15]  S. Posse,et al.  Enhancement of BOLD‐contrast sensitivity by single‐shot multi‐echo functional MR imaging , 1999, Magnetic resonance in medicine.

[16]  M. I. Argyropoulou,et al.  MRI evaluation of the basal ganglia size and iron content in patients with Parkinson's disease , 2005, Journal of Neurology.

[17]  D Matthaei,et al.  Rapid three-dimensional MR imaging using the FLASH technique. , 1986, Journal of computer assisted tomography.

[18]  P. Robitaille,et al.  Macroscopic susceptibility in ultra high field MRI. , 1999, Journal of computer assisted tomography.

[19]  A. Kangarlu,et al.  High resolution MRI of the deep gray nuclei at 8 Tesla. , 1999, Journal of computer assisted tomography.

[20]  Yu-Chung N. Cheng,et al.  Susceptibility weighted imaging (SWI) , 2004, Zeitschrift fur medizinische Physik.

[21]  J Yelnik,et al.  Contrast optimization of Macaca mulatta basal ganglia in magnetic resonance images at 4.7 Tesla , 2001, Journal of Neuroscience Methods.

[22]  M A Fernández-Seara,et al.  Postprocessing technique to correct for background gradients in image‐based R*2 measurements , 2000, Magnetic resonance in medicine.