Fluorometric method for phenylalanine microplate assay adapted for phenylketonuria screening.

We adapted the method of McCaman and Robins for fluorometry of phenylalanine to a microplate assay for routine phenylketonuria screening. Sensitivity is 15 mumol/L for the plasma assay and 30 mumol/L for the dried blood-spot assay, with CV less than 10% for both assays. Results for human plasma by microplate assay correlated well (r = 0.99) with results of amino acid analyzer determination of phenylalanine. When measurements are performed in an automated reader, the microplate assay has considerable advantages over conventional measurements in cuvettes: smaller volumes of reagents and automation enabling high throughput and convenience. Because the described method is a quantitative one, we can postulate that, compared with the semiquantitative Guthrie inhibition bioassay, this microplate assay is more reliable, easier to perform, and about twofold less costly.

[1]  R. Slover,et al.  Blood phenylalanine estimation for the patient with phenylketonuria using a portable device. , 1988, Biochemical medicine and metabolic biology.

[2]  J. Rutledge,et al.  Phenylalanine and tyrosine in serum and eluates from dried blood spots as determined by reversed-phase liquid chromatography. , 1987, Clinical chemistry.

[3]  G. Tsukerman [Simple method of mass screening for phenylketonuria]. , 1985, Laboratornoe delo.

[4]  E. McCabe,et al.  Newborn screening for phenylketonuria: predictive validity as a function of age. , 1983, Pediatrics.

[5]  C. Scriver More on newborn screening for phenylketonuria: recommendations of the Committee on Genetics. , 1983, Pediatrics.

[6]  H. Kirkman,et al.  Fifteen-year experience with screening for phenylketonuria with an automated fluorometric method. , 1982, American journal of human genetics.

[7]  B. Searle,et al.  A manual fluorometric paper disc method for detecting phenylketonuria. , 1967, Clinical chemistry.

[8]  J. Ambrose,et al.  A study of the fluorometric method for phenylalanine in serum samples. , 1967, Clinica chimica acta; international journal of clinical chemistry.

[9]  H R Irwin,et al.  Microfluorometric screening technic for phenylketonurias using filter paper sample collection. , 1967, Technical bulletin of the Registry of Medical Technologists. American Society of Clinical Pathologists. Registry of Medical Technologists.

[10]  An improved screening procedure for blood phenylalanine. , 1967, Nutrition reviews.

[11]  R. Vanderlinde,et al.  An improved screening procedure for blood phenylalanine. , 1966, Public health reports.

[12]  J. D. Rice,et al.  The use of filter paper PKU test specimen cards in the automated determination of blood phenylalanine concentration. , 1966, Technical bulletin of the Registry of Medical Technologists. American Society of Clinical Pathologists. Registry of Medical Technologists.

[13]  G. Summer,et al.  AN AUTOMATED PROCEDURE FOR BLOOD PHENYLALANINE. , 1965, Clinical chemistry.

[14]  P. Wong,et al.  MICROMETHODS FOR MEASURING PHENYLALANINE AND TYROSINE IN SERUM. , 1964, Clinical chemistry.

[15]  H. Slatis,et al.  SCREENING NEWBORN INFANTS FOR PHENYLKETONURIA. , 1964, JAMA.

[16]  R. Guthrie,et al.  PHENYLKETONURIA, DETECTION IN THE NEWBORN INFANT AS A ROUTINE HOSPITAL PROCEDURE. , 1964 .

[17]  R. Howell,et al.  A QUANTITATIVE MICROMETHOD FOR THE DETERMINATION OF PHENYLALANINE AND TYROSINE IN BLOOD AND ITS APPLICATION IN THE DIAGNOSIS OF PHENYLKETONURIA IN INFANTS , 1963, Pediatrics.

[18]  S. Jakovcic,et al.  Serum phenylalanine and tyrosine levels in the newborn infant. , 1962, New England Journal of Medicine.

[19]  E. Robins,et al.  Fluorimetric method for the determination of phenylalanine in serum , 1962 .

[20]  R. Guthrie,et al.  Blood Screening for Phenylketonuria , 1961 .

[21]  D. Tayloe,et al.  Pediatrics , 1927, The Indian Medical Gazette.