Single molecule studies of quantum dot conjugates in a submicrometer fluidic channel.

A microfluidic and optical system was created for the detection and analysis of single molecules in solution. Fluidic channels with submicrometer dimensions were used to isolate, detect and identify individual quantum dots conjugated with organic fluorophores. The channels were fabricated in fused silica with a 500 nm square cross section. The resulting focal volume of approximately 500 aL reduced fluorescent background and increased the signal to noise ratio of single molecule detection. The channels also enabled the rapid detection of 99% of quantum dots and organic fluorophores traversing the focal volume. Conjugates were driven through the channels electrokinetically at 2.3 kV cm(-1), excited with a single 476 nm wavelength laser and detected with a confocal microscope. Fluorescence emission was collected simultaneously from green (500-590 nm) and red (610-680 nm) regions of the spectrum. Signal rejection was minimized by the narrow and symmetric emission spectra of the quantum dots. To demonstrate efficient multicolor detection and characterization of single molecule binding, Qdot 655 Streptavidin Conjugates were bound to Alexa Fluor 488 molecules and individually detected. Photon counting histogram analysis was used to quantify coincident detection and degree of binding. Fluorescence correlation spectroscopy was used to measure the mobility of bound and unbound species. The union of fluidic channels with submicrometer dimensions and quantum dots as fluorescent labels resulted in efficient and rapid multiplexed single molecule detection and analysis.

[1]  Min Gu,et al.  Scanning total internal reflection fluorescence microscopy under one-photon and two-photon excitation: image formation. , 2004, Applied optics.

[2]  S. Weiss,et al.  Single-molecule spectroscopy and microscopy , 2002 .

[3]  Darwin R. Reyes,et al.  Micro total analysis systems. 2. Analytical standard operations and applications. , 2002, Analytical chemistry.

[4]  Optical spectroscopy of a single self-assembled quantum dot , 1998 .

[5]  M. Nirmal,et al.  Fluorescence intermittency in single cadmium selenide nanocrystals , 1996, Nature.

[6]  M. Bruchez,et al.  Optical coding of mammalian cells using semiconductor quantum dots. , 2004, Analytical biochemistry.

[7]  J. Edel,et al.  Determination of single particle flow velocities in microchannels using a maximum likelihood estimator method , 2003 .

[8]  Watt W. Webb,et al.  Fluorescence correlation spectroscopy. III. Uniform translation and laminar flow , 1978 .

[9]  J. Korlach,et al.  Focal volume confinement by submicrometer-sized fluidic channels. , 2004, Analytical chemistry.

[10]  J. Korlach,et al.  DNA fragment sizing by single molecule detection in submicrometer-sized closed fluidic channels. , 2002, Analytical chemistry.

[11]  Nigel Beard,et al.  Dealing with real samples: sample pre-treatment in microfluidic systems. , 2003, Lab on a chip.

[12]  P. Schwille,et al.  Dual-color fluorescence cross-correlation spectroscopy for multicomponent diffusional analysis in solution. , 1997, Biophysical journal.

[13]  Raymond P. Molloy,et al.  In vivo multiphoton microscopy of deep brain tissue. , 2004, Journal of neurophysiology.

[14]  Liming Ying,et al.  Ultrasensitive coincidence fluorescence detection of single DNA molecules. , 2003, Analytical chemistry.

[15]  David J. Nesbitt,et al.  ``On''/``off'' fluorescence intermittency of single semiconductor quantum dots , 2001 .

[16]  Darwin R. Reyes,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.