Comparison between wire mesh sensor and gamma densitometry void measurements in two-phase flows

Wire mesh sensors (WMS) are fast imaging instruments that are used for gas–liquid and liquid–liquid two-phase flow measurements and experimental investigations. Experimental tests were conducted at Helmholtz-Zentrum Dresden-Rossendorf to test both the capacitance and conductance WMS against a gamma densitometer (GD). A small gas–liquid test facility was utilized. This consisted of a vertical round pipe approximately 1 m in length, and 50 mm internal diameter. A 16 × 16 WMS was used with high spatial and temporal resolutions. Air–deionized water was the two-phase mixture. The gas superficial velocity was varied between 0.05 m s−1 and 1.4 m s−1 at two liquid velocities of 0.2 and 0.7 m s−1. The GD consisted of a collimated source and a collimated detector. The GD was placed on a moving platform close to the plane of wires of the sensor, in order to align it accurately using a counter mechanism, with each of the wires of the WMS, and the platform could scan the full section of the pipe. The WMS was operated as a conductivity WMS for a half-plane with eight wires and as a capacitance WMS for the other half. For the cross-sectional void (time and space averaged), along each wire, there was good agreement between WMS and the GD chordal void fraction near the centre of the pipe.

[1]  Barry J. Azzopardi,et al.  High-resolution gas–oil two-phase flow visualization with a capacitance wire-mesh sensor , 2010 .

[2]  Frank-Peter Weiss,et al.  Influence of the Pipe Diameter on the Structure of the Gas-Liquid Interface in a Vertical Two-Phase Pipe Flow , 2005 .

[3]  Geir Anton Johansen,et al.  Radioisotope Gauges for Industrial Process Measurements: Johansen/Industrial Process Measurements , 2005 .

[4]  Barry J. Azzopardi,et al.  Comparison between Electrical Capacitance Tomography and Wire Mesh Sensor Output for Air/Silicone Oil Flow in a Vertical Pipe , 2010 .

[5]  Dirk Lucas,et al.  Quality check of wire-mesh sensor measurements in a vertical air/water flow , 2010 .

[6]  Philipp Rudolf von Rohr,et al.  On the accuracy of void fraction measurements by single-beam gamma-densitometry for gas–liquid two-phase flows in pipes , 2004 .

[7]  Uwe Hampel,et al.  Measurement of Liquid Distributions in Particle Packings Using Wire-Mesh Sensor versus Transmission Tomographic Imaging , 2010 .

[8]  Sailesh Kumar,et al.  A γ-ray tomographic scanner for imaging voidage distribution in two-phase flow systems , 1995 .

[9]  Timothy J. O'Hern,et al.  Gamma-densitometry tomography of gas holdup spatial distribution in industrial-scale bubble columns , 1995 .

[10]  H. Prasser,et al.  A new electrode-mesh tomograph for gas–liquid flows , 1998 .

[11]  Yijun Jiang,et al.  An experimental study of the suitability of using a gamma densitometer for void fraction measurements in gas-liquid flow in a small diameter tube , 1993 .

[12]  Morten Christian Melaaen,et al.  Single-beam gamma densitometry measurements of oil–water flow in horizontal and slightly inclined pipes , 2010 .

[13]  A. A. Harms,et al.  The dynamic-bias in radiation interrogation of two-phase flow , 1973 .

[14]  Annalisa Manera,et al.  Comparison between wire-mesh sensors and conductive needle-probes for measurements of two-phase flow parameters , 2009 .

[15]  M. Petrick,et al.  Radiation Attenuation Method of Measuring Density of a Two‐Phase Fluid , 1958 .

[16]  Geoffrey F. Hewitt,et al.  Measurement of two phase flow parameters , 1978 .

[17]  U. Hampel,et al.  Capacitance wire-mesh sensor for fast measurement of phase fraction distributions , 2007 .

[18]  Barry J. Azzopardi,et al.  Comparative study of gas–oil and gas–water two-phase flow in a vertical pipe , 2010 .

[19]  Ion Tiseanu,et al.  Comparison between wire-mesh sensor and ultra-fast X-ray tomograph for an air–water flow in a vertical pipe , 2005 .

[20]  Trevor A. York Status of electrical tomography in industrial applications , 2001, J. Electronic Imaging.