Optical remote continuous sensing of intraocular pressure variations

We present the first steps of a new measurement principle for high-precision non-contact remote and continuous monitoring of intra-ocular pressure. A photonic device involving a fast camera and a laser is presented and tested in rabbit's eyes for continuous remote monitoring of the intra-ocular pressure. The device is based on tracking the secondary speckle patterns trajectories produced by reflection of an illuminating laser beam from the iris or the sclera. The rabbit's eyes were stimulated with increasing and decreasing ramps of intra-ocular pressure. Data from the photonic device were correlated with the induced intra-ocular pressure as consequence of the infusion bag elevation variations. The measurements show a good correlation and sensitivity of the proposed device with intra-ocular pressure changes while providing a high precision measurement (5% estimated error) for the best experimental configuration.

[1]  H. Kanngiesser,et al.  Contact lens tonometry--application in humans. , 1997, Investigative ophthalmology & visual science.

[2]  Zeev Zalevsky,et al.  Demonstration of remote optical measurement configuration that correlates to glucose concentration in blood , 2011, Biomedical optics express.

[3]  P. Renaud,et al.  First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens. , 2004, Investigative ophthalmology & visual science.

[4]  E. Chihara Assessment of true intraocular pressure: the gap between theory and practical data. , 2008, Survey of ophthalmology.

[5]  L A ERICSON,et al.  TWENTY‐FOUR HOURLY VARIATIONS IN THE INFLOW OF THE AQUEOUS HUMOUR , 1958, Acta ophthalmologica.

[6]  Wilensky Jt,et al.  Diurnal variations in intraocular pressure. , 1991 .

[7]  J. L. Hernández-Verdejo,et al.  Simultaneous measurement of intraocular pressure in the anterior chamber and the vitreous cavity , 2010, Acta ophthalmologica.

[8]  J. McLaren,et al.  Continuous measurement of intraocular pressure in rabbits by telemetry. , 1996, Investigative ophthalmology & visual science.

[9]  W. Feuer,et al.  Elevated intraocular pressure and hypotony following silicone oil retinal tamponade for complex retinal detachment: incidence and risk factors. , 1999, Archives of ophthalmology.

[10]  N. Voelcker,et al.  Advances in telemetric continuous intraocular pressure assessment , 2009, British Journal of Ophthalmology.

[11]  M. H. De la Torre-Ibarra,et al.  Double-shot depth-resolved displacement field measurement using phase-contrast spectral optical coherence tomography. , 2006, Optics express.

[12]  Bernard Grolman A NEW TONOMETER SYSTEM , 1973 .

[13]  Zeev Zalevsky,et al.  A microscope configuration for nanometer 3-D movement monitoring accuracy. , 2011, Micron.

[14]  西田 佳史 Motion detection system, a motion detector, a motion detecting method and a computer program , 2006 .

[15]  David A. Lee,et al.  Glaucoma and its treatment: a review. , 2005, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[16]  J. Wilensky,et al.  Diurnal variations in intraocular pressure. , 1991, Transactions of the American Ophthalmological Society.

[17]  P. Dubois,et al.  A New Method for Intra Ocular Pressure in vivo Measurement: First Clinical Trials , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  B K Pierscionek,et al.  Fluctuations in intraocular pressure and the potential effect on aberrations of the eye , 2007, British Journal of Ophthalmology.

[19]  Zeev Zalevsky,et al.  Simultaneous remote extraction of multiple speech sources and heart beats from secondary speckles pattern. , 2009, Optics express.

[20]  R. Nagata,et al.  Measurement by holographic interferometry of the deformation of the eye accompanying changes in intraocular pressure. , 1978, Applied optics.

[21]  Kaweh Mansouri,et al.  Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma , 2011, British Journal of Ophthalmology.

[22]  H. Quigley Number of people with glaucoma worldwide. , 1996, The British journal of ophthalmology.

[23]  Zeev Zalevsky,et al.  Remote estimation of blood pulse pressure via temporal tracking of reflected secondary speckles pattern. , 2010, Journal of biomedical optics.