Predicting real-time 3D deformation field maps (DFM) based on volumetric cine MRI (VC-MRI) and artificial neural networks for on-board 4D target tracking: a feasibility study.

PURPOSE To predict real-time 3D deformation field maps (DFMs) using Volumetric Cine MRI (VC-MRI) and adaptive boosting and multi-layer perceptron neural network (ADMLP-NN) for 4D target tracking. Methods: One phase of a prior 4D-MRI is set as the prior phase, MRI<sub>prior</sub>. Principal component analysis (PCA) is used to extract three major respiratory deformation modes from the DFMs generated between the prior and remaining phases. VC-MRI at each time-step is considered a deformation of MRI<sub>prior</sub>, where the DFM is represented as a weighted linear combination of the PCA components. The PCA weightings are solved by minimizing the differences between on-board 2D cine MRI and its corresponding VC-MRI slice. The PCA weightings solved during the initial training period are used to train an ADMLP-NN to predict PCA weightings ahead of time during the prediction period. The predicted PCA weightings are used to build predicted 3D DFM and ultimately, predicted VC-MRIs for 4D target tracking. The method was evaluated using a 4D computerized phantom (XCAT) with patient breathing curves and MRI data from a real liver cancer patient. Effects of breathing amplitude change and ADMLP-NN parameter variations were assessed. The accuracy of the PCA curve prediction was evaluated. The predicted real-time 3D tumor was evaluated against the ground-truth using Volume Dice Coefficient (VDC), Center-of-Mass-Shift (COMS), and target tracking errors. Results: For the XCAT study, the average VDC and COMS for the predicted tumor were 0.92 ± 0.02 and 1.06 ± 0.40 mm, respectively, across all predicted time-steps. The correlation coefficients between predicted and actual PCA curves generated through VC-MRI estimation for the 1st/2nd principal components were 0.98/0.89 and 0.99/0.57 in the SI and AP directions, respectively. The optimal number of input neurons, hidden neurons, and MLP-NN for ADMLP-NN PCA weighting coefficient prediction was determined to be 7, 4, and 10, respectively. The optimal cost function threshold was determined to be 0.05. PCA weighting coefficient and VC-MRI accuracy worsened with increasing prediction-step size. Accurate PCA weighting coefficient prediction correlated with accurate VC-MRI prediction. For the patient study, the predicted 4D tumor tracking errors in superior-inferior, anterior-posterior and lateral directions were 0.50 ± 0.47 mm, 0.40 ± 0.55 mm, and 0.28 ± 0.12 mm, respectively. Conclusion: Preliminary studies demonstrated the feasibility and robustness to use VC-MRI and artificial neural networks to predict real-time 3D DFMs of the tumor for 4D target tracking. .

[1]  Kristijan Macek,et al.  Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator. , 2016, Medical physics.

[2]  P. Levendag,et al.  Quality of life after stereotactic body radiation therapy for primary and metastatic liver tumors. , 2008, International journal of radiation oncology, biology, physics.

[3]  Fang-Fang Yin,et al.  Investigation of sagittal image acquisition for 4D-MRI with body area as respiratory surrogate. , 2014, Medical physics.

[4]  J. Balter,et al.  Stereotactic body radiation therapy for primary and metastatic liver tumors. , 2013, Translational oncology.

[5]  Paul J Keall,et al.  Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy. , 2010, International journal of radiation oncology, biology, physics.

[6]  Paul J Keall,et al.  First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking. , 2009, International journal of radiation oncology, biology, physics.

[7]  S. Korreman,et al.  Image-guided radiotherapy and motion management in lung cancer. , 2015, The British journal of radiology.

[8]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[9]  Steve B. Jiang,et al.  Single-Projection Based Volumetric Image Reconstruction and 3D Tumor Localization in Real Time for Lung Cancer Radiotherapy , 2010, MICCAI.

[10]  Tomas Krilavicius,et al.  Predicting Respiratory Motion for Real-Time Tumour Tracking in Radiotherapy , 2015, 2016 IEEE 29th International Symposium on Computer-Based Medical Systems (CBMS).

[11]  Teboh Roland,et al.  Incorporating system latency associated with real-time target tracking radiotherapy in the dose prediction step. , 2010, Physics in medicine and biology.

[12]  Jing Cai,et al.  Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study , 2017, Physics in medicine and biology.

[13]  Fang-Fang Yin,et al.  Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study. , 2011, Medical physics.

[14]  Fang-Fang Yin,et al.  Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy , 2017, Physics in medicine and biology.

[15]  Fang-Fang Yin,et al.  Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy , 2018, Medical physics.

[16]  Fang-Fang Yin,et al.  A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map. , 2008, Medical physics.

[17]  Fang-Fang Yin,et al.  Image acquisition optimization of a limited‐angle intrafraction verification (LIVE) system for lung radiotherapy , 2018, Medical physics.

[18]  Jeremy T Booth,et al.  Initial experience with intra‐fraction motion monitoring using Calypso guided volumetric modulated arc therapy for definitive prostate cancer treatment , 2017, Journal of medical radiation sciences.

[19]  B. Eswara Reddy,et al.  A moving-average filter based hybrid ARIMA-ANN model for forecasting time series data , 2014, Appl. Soft Comput..

[20]  Steve B. Jiang,et al.  On a PCA-based lung motion model , 2010, Physics in medicine and biology.

[21]  C. Chefd'Hotel,et al.  High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting , 2009, Magnetic resonance in medicine.

[22]  Cai Grau,et al.  Time-resolved dose distributions to moving targets during volumetric modulated arc therapy with and without dynamic MLC tracking. , 2013, Medical physics.

[23]  Lech Papiez,et al.  Stereotactic body radiation therapy for early-stage non-small-cell lung carcinoma: four-year results of a prospective phase II study. , 2009, International journal of radiation oncology, biology, physics.

[24]  Peter C Levendag,et al.  Stereotactic body radiation therapy for primary and metastatic liver tumors: A single institution phase i-ii study , 2006, Acta oncologica.

[25]  Hui Yan,et al.  Development and clinical evaluation of a three-dimensional cone-beam computed tomography estimation method using a deformation field map. , 2012, International journal of radiation oncology, biology, physics.

[26]  Fang-Fang Yin,et al.  A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging. , 2016, International journal of radiation oncology, biology, physics.

[27]  Peter Balter,et al.  Stereotactic ablative radiotherapy versus lobectomy for operable stage I non-small-cell lung cancer: a pooled analysis of two randomised trials. , 2015, The Lancet. Oncology.

[28]  W. Segars,et al.  4D XCAT phantom for multimodality imaging research. , 2010, Medical physics.

[29]  Hui Yan,et al.  Adaptive prediction of internal target motion using external marker motion: a technical study , 2006, Physics in medicine and biology.