A Precise Review on Applications and Basic Concept of Direct Analysis in Real Time Mass Spectrometry (DART-MS)

Direct real time analysis (DART) is the most successful tool for the analysis of the compounds. This technique is useful for the identification, and classification of compounds. It is widely followed by the forensic chemistry, and also used for many purposes. Their main applications include inks, paints, drugs, bank dyes, explosives, beverages, and gunshot etc. The basic concepts of DART-MS were highlighted to understand the process. Also the basic fundamentals of DART-MS including special function were discussed. Various natural products were discovered by DART-MS includes plant tissue, insects, and microbe etc. The main focus of this review article is on the applications of direct real time analysis, which covers the varieties of uses in our pharmaceutical as well as chemical industries. This technique was helpful in the production of food material, and to identify the contaminants from animal sources in the part of veterinary drugs. Also, used in food processing in the form of additives, and adulterants. DART-MS has huge applications on analysis of seized drug like steroids supplements, psychoactive plants etc. Also, in inks, paint, and documents industry this technique has been widely used. So, this review covers the basic fundamentals of direct real time analysis DART-MS, and their applications.

[1]  Steven J Ray,et al.  Atmospheric pressure chemical ionization source. 1. Ionization of compounds in the gas phase. , 2008, Analytical chemistry.

[2]  R. Cooks,et al.  Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization , 2004, Science.

[3]  G. Glish,et al.  Direct analysis of herbicides by paper spray ionization mass spectrometry , 2015 .

[4]  R. Cooks,et al.  Thermal formation of mixed-metal inorganic complexes at atmospheric pressure. , 2008, Rapid communications in mass spectrometry : RCM.

[5]  A. Dane,et al.  Selective ionization of melamine in powdered milk by using argon direct analysis in real time (DART) mass spectrometry. , 2010, The Analyst.

[6]  Jana Hajslova,et al.  Ambient mass spectrometry employing direct analysis in real time (DART) ion source for olive oil quality and authenticity assessment. , 2009, Analytica chimica acta.

[7]  R. Kostiainen,et al.  Environmental and food analysis by desorption atmospheric pressure photoionization-mass spectrometry. , 2010, Rapid communications in mass spectrometry : RCM.

[8]  S. Kéki,et al.  Fast identification of phthalic acid esters in poly(vinyl chloride) samples by Direct Analysis In Real Time (DART) tandem mass spectrometry , 2011 .

[9]  R. Graham Cooks,et al.  Ambient desorption ionization mass spectrometry , 2008 .

[10]  Joachim Franzke,et al.  Simultaneous testing of multiclass organic contaminants in food and environment by liquid chromatography/dielectric barrier discharge ionization-mass spectrometry. , 2012, The Analyst.

[11]  D. I. Carroll,et al.  Atmospheric pressure ionization mass spectrometry. Corona discharge ion source for use in a liquid chromatograph-mass spectrometer-computer analytical system , 1975 .

[12]  Liguo Song,et al.  Ionization mechanism of negative ion-direct analysis in real time: A comparative study with negative ion-atmospheric pressure photoionization , 2009, Journal of the American Society for Mass Spectrometry.

[13]  I. Chernushevich,et al.  A collisional focusing ion guide for coupling an atmospheric pressure ion source to a mass spectrometer , 1997 .

[14]  M. Tsuchiya,et al.  A New Ionization Method for Organic Compounds.-Liquid Ionization at Atmospheric Pressure Utilizing Penning Effect and Chemical Ionization , 1978 .

[15]  D. Weston Ambient ionization mass spectrometry: current understanding of mechanistic theory; analytical performance and application areas. , 2010, The Analyst.

[16]  J. Nilles,et al.  Explosives Detection Using Direct Analysis in Real Time (DART) Mass Spectrometry , 2010 .

[17]  F. Song,et al.  Argon direct analysis in real time mass spectrometry in conjunction with makeup solvents: a method for analysis of labile compounds. , 2013, Analytical chemistry.

[18]  A. Marshall,et al.  The coupling of direct analysis in real time ionization to Fourier transform ion cyclotron resonance mass spectrometry for ultrahigh-resolution mass analysis. , 2010, Rapid communications in mass spectrometry : RCM.

[19]  C. Klampfl,et al.  Rapid identification of stabilisers in polypropylene using time-of-flight mass spectrometry and DART as ion source. , 2010, The Analyst.

[20]  S. Kern,et al.  Accurate Mass Fragment Library for Rapid Analysis of Pesticides on Produce Using Ambient Pressure Desorption Ionization with High-Resolution Mass Spectrometry , 2014, Journal of The American Society for Mass Spectrometry.

[21]  M. Bertrand,et al.  Selective fragmentation and ionization of organic compounds using an energy-tunable rare-gas metastable beam source , 1993 .

[22]  C. Gagnon,et al.  High-throughput quantitation of seven sulfonamide residues in dairy milk using laser diode thermal desorption-negative mode atmospheric pressure chemical ionization tandem mass spectrometry. , 2010, Journal of agricultural and food chemistry.

[23]  Shammy Jindal,et al.  Development and Characterization of Barbaloin Gel for the Safe and Effective Treatment of Psoriasis , 2020 .

[24]  F. Fernández,et al.  Simulations and experimental investigation of atmospheric transport in an ambient metastable-induced chemical ionization source. , 2009, Analytical chemistry.

[25]  M. Nielen,et al.  Feasibility of desorption electrospray ionization mass spectrometry for rapid screening of anabolic steroid esters in hair. , 2011, Analytica chimica acta.

[26]  A. Marshall,et al.  High-resolution mass spectrometers. , 2008, Annual review of analytical chemistry.

[27]  J. Yew Natural Product Discovery by Direct Analysis in Real Time Mass Spectrometry , 2019, Mass spectrometry.

[28]  K. Hiraoka,et al.  Development of double cylindrical dielectric barrier discharge ion source. , 2011, The Analyst.

[29]  R. Cooks,et al.  Ambient Mass Spectrometry , 2006, Science.

[30]  Robert Winkler,et al.  'Plug and Play' assembly of a low-temperature plasma ionization mass spectrometry imaging (LTP-MSI) system. , 2014, Journal of proteomics.

[31]  C. McEwen,et al.  Ionization mechanisms related to negative Ion APPI, APCI, and DART , 2009 .

[32]  R. R. Steiner,et al.  Development and validation of AccuTOF-DART™ as a screening method for analysis of bank security device and pepper spray components. , 2011, Forensic science international.

[33]  R. N. Stillwell,et al.  Comparison of positive ions formed in nickel-63 and corona discharge ion sources using nitrogen, argon, isobutane, ammonia and nitric oxide as reagents in atmospheric pressure ionization mass spectrometry , 1976 .

[34]  V. Pandit,et al.  Treatment and management for patients with mild to severe psoriasis: A review , 2020 .

[35]  DART mass spectrometry and its applications in chemical analysis , 2011 .

[36]  Navdeep Singh,et al.  Traditional and medicinal use of Barbaloin: potential for the management of various diseases , 2020 .

[37]  J. Franzke,et al.  Ambient diode laser desorption dielectric barrier discharge ionization mass spectrometry of nonvolatile chemicals. , 2013, Analytical chemistry.

[38]  R. Cooks,et al.  Thermal production and reactions of organic ions at atmospheric pressure. , 2006, Angewandte Chemie.

[39]  Randy L. Self,et al.  Rapid qualitative analysis of phthalates added to food and nutraceutical products by direct analysis in real time/orbitrap mass spectrometry , 2012 .

[40]  J. Steinfeld,et al.  Explosives detection: a challenge for physical chemistry. , 1998, Annual review of physical chemistry.

[41]  G. O’Connor,et al.  Ambient mass spectrometry: advances and applications in forensics , 2010 .

[42]  K. Hiraoka,et al.  Quantitative Aspects of Atmospheric-Pressure Penning Ionization , 2010 .

[43]  R. Cody Observation of molecular ions and analysis of nonpolar compounds with the direct analysis in real time ion source. , 2009, Analytical chemistry.

[44]  R. Cody,et al.  Versatile new ion source for the analysis of materials in open air under ambient conditions. , 2005, Analytical chemistry.

[45]  A. Bruins,et al.  Atmospheric pressure photoionization: an ionization method for liquid chromatography-mass spectrometry , 2000, Analytical chemistry.