Automated artifact removal as preprocessing refines neonatal seizure detection

OBJECTIVE The description and evaluation of algorithms using Independent Component Analysis (ICA) for automatic removal of ECG, pulsation and respiration artifacts in neonatal EEG before automated seizure detection. METHODS The developed algorithms decompose the EEG using ICA into its underlying sources. The artifact source was identified using the simultaneously recorded polygraphy signals after preprocessing. The EEG was reconstructed without the corrupting source, leading to a clean EEG. The impact of the artifact removal was measured by comparing the performance of a previously developed seizure detector before and after the artifact removal in 13 selected patients (9 having artifact-contaminated and 4 having artifact-free EEGs). RESULTS A significant decrease in false alarms (p=0.01) was found while the Good Detection Rate (GDR) for seizures was not altered (p=0.50). CONCLUSIONS The techniques reduced the number of false positive detections without lowering sensitivity and are beneficial in long term EEG seizure monitoring in the presence of disturbing biological artifacts. SIGNIFICANCE The proposed algorithms improve neonatal seizure monitoring.

[1]  Soo-Young Lee Blind Source Separation and Independent Component Analysis: A Review , 2005 .

[2]  G. Lightbody,et al.  EEG-based neonatal seizure detection with Support Vector Machines , 2011, Clinical Neurophysiology.

[3]  J. Frost,et al.  A Multistage System for the Automated Detection of Epileptic Seizures in Neonatal Electroencephalography , 2009, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[4]  Perumpillichira J. Cherian,et al.  Technical standards for recording and interpretation of neonatal electroencephalogram in clinical practice , 2009, Annals of Indian Academy of Neurology.

[5]  Sabine Van Huffel,et al.  Spatially constrained ICA algorithm with an application in EEG processing , 2011, Signal Process..

[6]  Christopher J James,et al.  Independent component analysis for biomedical signals , 2005, Physiological measurement.

[7]  Eric Moulines,et al.  A blind source separation technique using second-order statistics , 1997, IEEE Trans. Signal Process..

[8]  Pierre Comon,et al.  Robust Independent Component Analysis by Iterative Maximization of the Kurtosis Contrast With Algebraic Optimal Step Size , 2010, IEEE Transactions on Neural Networks.

[9]  Matthew T. Sutherland,et al.  Validation of SOBI components from high-density EEG , 2005, NeuroImage.

[10]  S. Huffel,et al.  Automated neonatal seizure detection mimicking a human observer reading EEG , 2008, Clinical Neurophysiology.

[11]  J. Cardoso,et al.  Blind beamforming for non-gaussian signals , 1993 .

[12]  Junshui Ma,et al.  High-throughput ocular artifact reduction in multichannel electroencephalography (EEG) using component subspace projection , 2011, Journal of Neuroscience Methods.

[13]  P. Strobach,et al.  Event-synchronous cancellation of the heart interference in biomedical signals , 1994, IEEE Transactions on Biomedical Engineering.

[14]  I Rosén,et al.  Silent Seizures in Sick Infants in Early Life , 1985, Acta paediatrica Scandinavica.

[15]  Yong Yang,et al.  Automatic Removal of Eye-Movement and Blink Artifacts from EEG Signals , 2010, Brain Topography.

[16]  Seungjin Choi Blind Source Separation and Independent Component Analysis : A Review , 2004 .

[17]  S. Makeig,et al.  Imaging human EEG dynamics using independent component analysis , 2006, Neuroscience & Biobehavioral Reviews.

[18]  C. Joyce,et al.  Automatic removal of eye movement and blink artifacts from EEG data using blind component separation. , 2004, Psychophysiology.

[19]  Miguel Angel Mañanas,et al.  A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: A simulation case , 2008, Comput. Biol. Medicine.

[20]  D. Lanska,et al.  Neonatal seizures in the United States: results of the National Hospital Discharge Survey, 1980-1991. , 1996, Neuroepidemiology.

[21]  Sabine Van Huffel,et al.  Removal of Muscle Artifacts from EEG Recordings of Spoken Language Production , 2010, Neuroinformatics.

[22]  Sabine Van Huffel,et al.  Removal of BCG artifacts from EEG recordings inside the MR scanner: A comparison of methodological and validation-related aspects , 2010, NeuroImage.

[23]  G B Boylan,et al.  Defining the gap between electrographic seizure burden, clinical expression and staff recognition of neonatal seizures , 2007, Archives of Disease in Childhood Fetal and Neonatal Edition.

[24]  J. F. Kaiser,et al.  On a simple algorithm to calculate the 'energy' of a signal , 1990, International Conference on Acoustics, Speech, and Signal Processing.

[25]  G. Lightbody,et al.  Performance assessment for EEG-based neonatal seizure detectors , 2011, Clinical Neurophysiology.

[26]  Patrick Dupont,et al.  Canonical decomposition of ictal scalp EEG reliably detects the seizure onset zone , 2007, NeuroImage.

[27]  J. Volpe Neurology of the Newborn , 1959, Major problems in clinical pediatrics.

[28]  Erkki Oja,et al.  Independent Component Analysis , 2001 .

[29]  Wim Van Paesschen,et al.  Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram , 2006, IEEE Transactions on Biomedical Engineering.

[30]  Hyunwoo Nam,et al.  Independent Component Analysis of Ictal EEG in Medial Temporal Lobe Epilepsy , 2002, Epilepsia.

[31]  M. De Vos,et al.  Validation of a new automated neonatal seizure detection system: A clinician’s perspective , 2011, Clinical Neurophysiology.

[32]  Jens Haueisen,et al.  Independent component analysis: comparison of algorithms for the investigation of surface electrical brain activity , 2009, Medical & Biological Engineering & Computing.

[33]  Bart Vanrumste,et al.  Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP. , 2010, Psychophysiology.