An In-Principle Method for Measuring Cardiac Tissue Fibre Rotation

Four electrode techniques have long been used to deter- mine conductivity parameters in cardiac tissue. This paper introduces a mathematical model and solution technique to theoretically analyse electrode configurations, specifically allowing for plunge electrodes. In particular, the focus is on using four electrode configurations to deter- mine fibre rotation in cardiac tissue. Two configurations are analysed, the first with the four electrodes collinear and the second consisting of two probes a fixed distance apart, with the current electrodes on one probe and the measuring electrodes on the other. It is found that the sec- ond electrode configuration can yield a value for the fibre rotation under the assumptions of the model.

[1]  R. Gulrajani Bioelectricity and biomagnetism , 1998 .

[2]  A. M. Scher,et al.  Effect of Tissue Anisotropy on Extracellular Potential Fields in Canine Myocardium in Situ , 1982, Circulation research.

[3]  Myocardial impedance measurements with a modified four electrode technique , 1994, Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  P. Hunter,et al.  Laminar structure of the heart: a mathematical model. , 1997, The American journal of physiology.

[5]  Peter R. Johnston,et al.  The effect of conductivity values on ST segment shift in subendocardial ischaemia , 2003, IEEE Transactions on Biomedical Engineering.

[6]  Otto H. Schmitt,et al.  Biological Information Processing Using the Concept of Interpenetrating Domains , 1969 .

[7]  D. Geselowitz,et al.  Simulation Studies of the Electrocardiogram: I. The Normal Heart , 1978, Circulation research.

[8]  J. E. Glynn,et al.  Numerical Recipes: The Art of Scientific Computing , 1989 .

[9]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[10]  S. Weidmann Electrical constants of trabecular muscle from mammalian heart , 1970, The Journal of physiology.

[11]  P. Johnston A cylindrical model for studying subendocardial ischaemia in the left ventricle. , 2003, Mathematical biosciences.

[12]  Peter R. Johnston,et al.  The importance of anisotropy in modeling ST segment shift in subendocardial ischaemia , 2001, IEEE Transactions on Biomedical Engineering.

[13]  Yongmin Kim,et al.  An investigation of the importance of myocardial anisotropy in finite-element modeling of the heart: methodology and application to the estimation of defibrillation efficacy , 2001, IEEE Transactions on Biomedical Engineering.

[14]  P. Savard,et al.  Extracellular Measurement of Anisotropic Bidomain Myocardial Conductivities. I. Theoretical Analysis , 2001, Annals of Biomedical Engineering.

[15]  L. Clerc Directional differences of impulse spread in trabecular muscle from mammalian heart. , 1976, The Journal of physiology.

[16]  Leslie Tung,et al.  A bi-domain model for describing ischemic myocardial d-c potentials , 1978 .

[17]  P. C. Franzone,et al.  Spreading of excitation in 3-D models of the anisotropic cardiac tissue. I. Validation of the eikonal model. , 1993, Mathematical biosciences.

[18]  Robert Plonsey,et al.  The Four-Electrode Resistivity Technique as Applied to Cardiac Muscle , 1982, IEEE Transactions on Biomedical Engineering.

[19]  A. M. Scher,et al.  Influence of Cardiac Fiber Orientation on Wavefront Voltage, Conduction Velocity, and Tissue Resistivity in the Dog , 1979, Circulation research.

[20]  Dd. Streeter,et al.  Gross morphology and fiber geometry of the heart , 1979 .

[21]  W. Krassowska,et al.  Effective boundary conditions for syncytial tissues , 1994, IEEE Transactions on Biomedical Engineering.

[22]  Robert Plonsey,et al.  Electrode systems for measuring cardiac impedances using optical transmembrane potential sensors and interstitial electrodes-theoretical design , 2003, IEEE Transactions on Biomedical Engineering.

[23]  B. Roth Electrical conductivity values used with the bidomain model of cardiac tissue , 1997, IEEE Transactions on Biomedical Engineering.