An inter-laboratory study of the calibration of optical full-field systems for measuring deformation

A calibration of optical full-field systems for measuring deformation is performed using a physical Reference Material that reproduces fields of strain and deformation. Traceability of the measurement results is established by applying a calibrated transducer at a selected point and using an analytic description of the deformation field to extend traceability to the entire gauge area. A Reference Material based on a cantilever together with a protocol for its use had been suggested for both static and dynamic calibrations in a CEN Workshop Agreement. They have been challenged in an inter-laboratory study of calibration conducted on an international scale. We report results of this inter-laboratory study of calibration which prove that the Cantilever Reference Material is sufficiently stable and reproducible to be used as a calibration artefact for displacement and strain fields in static and dynamic loading. Participants applied the Cantilever Reference Material in a range of tip deflections from 2 μm to 4.7 mm. Deformation from static bending is shown to be linear in the tip deflection up to the highest loads applied thus providing evidence that the reference values of the calibration artefact are appropriate. In dynamic loading, the first resonant bending mode has proven especially useful for the purpose of calibration. While the calibration procedure proved to be viable, the feed-back of the participants led to a number of modifications to the relevant chapter of the CEN Workshop Agreement, for example, as to the estimation of calibration uncertainty.

[1]  Annett Wechsler,et al.  Formulas For Natural Frequency And Mode Shape , 2016 .

[2]  Maurice Whelan,et al.  The Development of a Reference Material for Calibration of Full-Field Optical Measurement Systems for Dynamic Deformation Measurements , 2011 .

[3]  George Z. Forristall,et al.  Wave Crest Sensor Intercomparison Study: An Overview of WACSIS , 2004 .

[4]  P. Bievre The 2007 International Vocabulary of Metrology (VIM), JCGM 200:2008 [ISO/IEC Guide 99]: Meeting the need for intercontinentally understood concepts and their associated intercontinentally agreed terms. , 2009 .

[5]  Roberto Marsili,et al.  Thermoelastic Stress Analysis of the contact between a flat plate and a cylinder , 2014 .

[6]  R. Y. Tsai,et al.  An Efficient and Accurate Camera Calibration Technique for 3D Machine Vision , 1986, CVPR 1986.

[7]  Renato Affri,et al.  Metrological Characterization Of Optical Measuring System For Hardness Indenters , 2002 .

[8]  Eann A. Patterson,et al.  Calibration of a digital image correlation system , 2015, Experimental Techniques.

[9]  Maurice Whelan,et al.  Calibration and evaluation of optical systems for full-field strain measurement , 2007 .

[10]  Maurice Whelan,et al.  Calibration of a Speckle Interferometry Full‐Field Strain Measurement System , 2008 .

[11]  Eann A. Patterson,et al.  A reference material for establishing uncertainties in full-field displacement measurements , 2015 .

[12]  Guangjun Zhang,et al.  A calibration method for stereo vision sensor with large FOV based on 1D targets , 2011 .

[13]  Edward Hæggström,et al.  Quasidynamic calibration of stroboscopic scanning white light interferometer with a transfer standard , 2013 .

[14]  Duane C. Brown,et al.  Close-Range Camera Calibration , 1971 .

[15]  Leonard Steinborn,et al.  International Organization for Standardization ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories , 2004 .