Numerical Thermal Analysis of a Wireless Cortical Implant with Two-Body Packaging

This article presents the numerical analysis of temperature elevation in the head due to the operation of a wireless cortical implant. The thermal analyses are done by using a finite-difference time-domain simulation tool and a high-resolution 3-D head phantom with 22 different tissues. The effects of the power dissipation level, size, location, and packaging of the implant on the temperature distribution in the head are investigated by using a generic silicon chip. Furthermore, the distribution of the power consumption in the implant by using multiple integrated circuits is discussed. In order not to exceed the safety precaution limit of 1°C, maximum allowable power dissipation in a chip of size 2 × 2 × 0.5 mm3 is found to be 5.3 mW, whereas it is 9.3 mW for an implant with two chips of the same size separated by 10 mm. Additionally, the thermal analysis of a wireless cortical implant is also done by using a two-body cortical implant prototype. Maximum allowable power consumption for the two-body implant is found as 35 mW, whereas the unibody implant can only dissipate 17.5 mW without exceeding the safety precaution limit. By using the two-body implant, the maximum allowable power consumption in the implant can be increased or the temperature elevation in the tissues can be decreased.

[1]  Shira M. Lee Finite element simulation and parameter optimization of a flexible tactile pressure sensor array , 2005 .

[2]  Daryl R. Kipke,et al.  Wireless implantable microsystems: high-density electronic interfaces to the nervous system , 2004, Proceedings of the IEEE.

[3]  S. C. DeMarco,et al.  Computed SAR and thermal elevation in a 0.25-mm 2-D model of the human eye and head in response to an implanted retinal stimulator - part I: models and methods , 2003 .

[4]  Catherine Dehollain,et al.  Numerical analysis of temperature elevation in the head due to power dissipation in a cortical implant , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  M J Ackerman,et al.  The Visible Human Project , 1998, Proc. IEEE.

[6]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[7]  R.R. Harrison,et al.  A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System , 2006, IEEE Journal of Solid-State Circuits.

[8]  C. Dehollain,et al.  Orthogonally oriented coils for minimization of cross-coupling in cortical implants , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[9]  Eleanor R. Adair,et al.  Microwaves and thermoregulation , 1983 .

[10]  R. Rennaker,et al.  Electromagnetic Power Absorption and Temperature Changes due to Brain Machine Interface Operation , 2007, Annals of Biomedical Engineering.

[11]  J. D. Lorge The Thermal Basis for Disruption of Operant Behavior by Microwaves in Three Animal Species , 1982 .

[12]  C. Van Hoof,et al.  A 3D slim-base probe array for in vivo recorded neuron activity , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Catherine Dehollain,et al.  Inductive power link for a wireless cortical implant with biocompatible packaging , 2010, 2010 IEEE Sensors.

[14]  James D. Weiland,et al.  Thermal elevation in the human eye and head due to the operation of a retinal prosthesis , 2004, IEEE Transactions on Biomedical Engineering.

[15]  Chang Liu,et al.  Re-configurable fluid circuits by PDMS elastomer micromachining , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).

[16]  Steven T. Wereley,et al.  Design, fabrication and characterization of a conducting PDMS for microheaters and temperature sensors , 2009 .

[17]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[18]  G. Lazzi,et al.  Thermal effects of bioimplants , 2005, IEEE Engineering in Medicine and Biology Magazine.

[19]  Craig T. Nordhausen,et al.  Single unit recording capabilities of a 100 microelectrode array , 1996, Brain Research.

[20]  R. Normann,et al.  Thermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[21]  Paolo Bernardi,et al.  Specific absorption rate and temperature elevation in a subject exposed in the far-field of radio-frequency sources operating in the 10-900-MHz range , 2003, IEEE Transactions on Biomedical Engineering.

[22]  Michael John Ackerman,et al.  The Visible Human Project. , 1991 .