Comparison between infrared optical and stereoscopic X-ray technologies for patient setup in image guided stereotactic radiotherapy.

PURPOSE To compare infrared (IR) optical vs. stereoscopic X-ray technologies for patient setup in image-guided stereotactic radiotherapy. METHODS AND MATERIALS Retrospective data analysis of 233 fractions in 127 patients treated with hypofractionated stereotactic radiotherapy was performed. Patient setup at the linear accelerator was carried out by means of combined IR optical localization and stereoscopic X-ray image fusion in 6 degrees of freedom (6D). Data were analyzed to evaluate the geometric and dosimetric discrepancy between the two patient setup strategies. RESULTS Differences between IR optical localization and 6D X-ray image fusion parameters were on average within the expected localization accuracy, as limited by CT image resolution (3 mm). A disagreement between the two systems below 1 mm in all directions was measured in patients treated for cranial tumors. In extracranial sites, larger discrepancies and higher variability were observed as a function of the initial patient alignment. The compensation of IR-detected rotational errors resulted in a significantly improved agreement with 6D X-ray image fusion. On the basis of the bony anatomy registrations, the measured differences were found not to be sensitive to patient breathing. The related dosimetric analysis showed that IR-based patient setup caused limited variations in three cases, with 7% maximum dose reduction in the clinical target volume and no dose increase in organs at risk. CONCLUSIONS In conclusion, patient setup driven by IR external surrogates localization in 6D featured comparable accuracy with respect to procedures based on stereoscopic X-ray imaging.

[1]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[2]  B. Fallone,et al.  First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system. , 2009, Medical physics.

[3]  Cristina Garibaldi,et al.  3D optoelectronic analysis of interfractional patient setup variability in frameless extracranial stereotactic radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[4]  David A Jaffray,et al.  Emergent technologies for 3-dimensional image-guided radiation delivery. , 2005, Seminars in radiation oncology.

[5]  A. Brahme,et al.  4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures. , 2008, Medical physics.

[6]  D. Jaffray,et al.  Advances in image-guided radiation therapy. , 2007, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[7]  Timothy D. Solberg,et al.  Infrared patient positioning for stereotactic radiosurgery of extracranial tumors , 1999, Comput. Biol. Medicine.

[8]  J. Balter,et al.  Imaging and alignment for image-guided radiation therapy. , 2007, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[9]  J. Cox,et al.  Implementation of daily image‐guided radiation therapy using an in‐room CT scanner for prostate cancer isocentre localization , 2009, Journal of medical imaging and radiation oncology.

[10]  Early clinical experience with kilovoltage image-guided radiation therapy for interfraction motion management. , 2008, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[11]  L. Chin,et al.  Infrared-guided patient setup for lung cancer patients. , 2008, International journal of radiation oncology, biology, physics.

[12]  Frederik Wenz,et al.  Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT): MV portal images vs. kV portal images vs. cone-beam CT. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  D. Verellen,et al.  Six dimensional analysis with daily stereoscopic x-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks. , 2006, Medical physics.

[14]  Jean Pouliot,et al.  Megavoltage imaging, megavoltage cone beam CT and dose-guided radiation therapy. , 2007, Frontiers of radiation therapy and oncology.

[15]  L. Xing,et al.  Overview of image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[16]  Dirk Verellen,et al.  A (short) history of image-guided radiotherapy. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[18]  Dirk Verellen,et al.  Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  Steve B. Jiang,et al.  4D-CT lung motion estimation with deformable registration: quantification of motion nonlinearity and hysteresis. , 2008, Medical physics.

[20]  Andrea Bezjak,et al.  Cone-beam computed tomographic image guidance for lung cancer radiation therapy. , 2009, International journal of radiation oncology, biology, physics.

[21]  W. Schlegel,et al.  Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax , 2007, Physics in medicine and biology.

[22]  Gregory C Sharp,et al.  Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations. , 2008, Medical physics.

[23]  Clifton D Fuller,et al.  Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies. , 2004, International journal of radiation oncology, biology, physics.

[24]  Bill J Salter,et al.  Image-guidance for stereotactic body radiation therapy. , 2007, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[25]  Timothy D Solberg,et al.  Targeting accuracy of an image guided gating system for stereotactic body radiotherapy , 2005, Physics in medicine and biology.

[26]  D Verellen,et al.  Electronic portal imaging with on-line correction of setup error in thoracic irradiation: clinical evaluation. , 1998, International journal of radiation oncology, biology, physics.

[27]  Fang-Fang Yin,et al.  Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy. , 2008, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[28]  Cristina Garibaldi,et al.  Robust frameless stereotactic localization in extra-cranial radiotherapy. , 2006, Medical physics.

[29]  Patrick A Kupelian,et al.  Observations on real-time prostate gland motion using electromagnetic tracking. , 2008, International journal of radiation oncology, biology, physics.

[30]  Ross I Berbeco,et al.  Clinical feasibility of using an EPID in CINE mode for image-guided verification of stereotactic body radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[31]  Hassan Mostafavi,et al.  Dynamic targeting image-guided radiotherapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.