Continuous Blood Pressure Monitoring as a Basis for Ambient Assisted Living (AAL) – Review of Methodologies and Devices

Blood pressure (BP) is a bio-physiological signal that can provide very useful information regarding human’s general health. High or low blood pressure or its rapid fluctuations can be associated to various diseases or conditions. Nowadays, high blood pressure is considered to be an important health risk factor and major cause of various health problems worldwide. High blood pressure may precede serious heart diseases, stroke and kidney failure. Accurate blood pressure measurement and monitoring plays fundamental role in diagnosis, prevention and treatment of these diseases. Blood pressure is usually measured in the hospitals, as a part of a standard medical routine. However, there is an increasing demand for methodologies, systems as well as accurate and unobtrusive devices that will permit continuous blood pressure measurement and monitoring for a wide variety of patients, allowing them to perform their daily activities without any disturbance. Technological advancements in the last decade have created opportunities for using various devices as a part of ambient assisted living for improving quality of life for people in their natural environment. The main goal of this paper is to provide a comprehensive review of various methodologies for continuous cuff-less blood pressure measurement, as well as to evidence recently developed devices and systems for continuous blood pressure measurement that can be used in ambient assisted living applications.

[1]  Tapas Mondal,et al.  Wearable Sensors for Remote Health Monitoring , 2017, Sensors.

[2]  Hwee Tou Ng,et al.  Model-Based, Multiple-Fault Diagnosis of Dynamic, Continuous Physical Devices , 1991, IEEE Expert.

[3]  J. Hahn,et al.  Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method , 2018, Science Translational Medicine.

[4]  Vahram Mouradian,et al.  Noninvasive continuous mobile blood pressure monitoring using novel PPG optical sensor , 2015, 2015 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS).

[5]  Jesús Lázaro,et al.  Pulse transit time and pulse width as potential measure for estimating beat-to-beat systolic and diastolic blood pressure , 2013, Computing in Cardiology 2013.

[6]  Hoda Mohammadzade,et al.  Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time , 2015, 2015 IEEE International Symposium on Circuits and Systems (ISCAS).

[7]  Reinhold Orglmeister,et al.  Novel computation of pulse transit time from multi-channel PPG signals by wavelet transform , 2016 .

[8]  Shivaraman Ilango,et al.  A Non-Invasive Blood Pressure Measurement using Android Smart Phones , 2014 .

[9]  D. Tabatabai Cuff-Less and Calibration Free Blood Pressure Estimation Using the Pulse Transit Time Method , 2022 .

[10]  Peter Xiaoping Liu,et al.  Using Eulerian video magnification framework to measure pulse transit time , 2014, 2014 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[11]  Carmen C. Y. Poon,et al.  Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[12]  Federico S. Cattivelli,et al.  Noninvasive Cuffless Estimation of Blood Pressure from Pulse Arrival Time and Heart Rate with Adaptive Calibration , 2009, 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks.

[13]  Sujay Deb,et al.  An affordable cuff-less blood pressure estimation solution , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[14]  P. Reis,et al.  Correlation study between blood pressure and pulse transit time , 2015, 2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG).

[15]  Surendhra Goli,et al.  Cuff less Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time Measurement , 2014 .

[16]  Angshul Majumdar,et al.  A sparse regression based approach for cuff-less blood pressure measurement , 2016, 2016 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[17]  Peter Xiaoping Liu,et al.  Evaluation of the correlation between blood pressure and pulse transit time , 2013, 2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[18]  Domenico Grimaldi,et al.  A Neural Network-based method for continuous blood pressure estimation from a PPG signal , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[19]  Chris D. Nugent,et al.  Biomedical Sensors for Ambient Assisted Living , 2010 .

[20]  H. K. Leung,et al.  A novel method for the contactless and continuous measurement of arterial blood pressure on a sleeping bed , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Ming Liu,et al.  Novel wavelet neural network algorithm for continuous and noninvasive dynamic estimation of blood pressure from photoplethysmography , 2016, Science China Information Sciences.

[22]  M. Szczyrek,et al.  Hypertension – The Silent Killer , 2011 .

[23]  Yan Chen,et al.  Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity , 2009, Annals of Biomedical Engineering.

[24]  Saso Koceski,et al.  Suppression of Intensive Care Unit False Alarms Based on the Arterial Blood Pressure Signal , 2017, IEEE Access.

[25]  Nilanjan Ray,et al.  Continuous blood pressure prediction from pulse transit time using ECG and PPG signals , 2016, 2016 IEEE Healthcare Innovation Point-Of-Care Technologies Conference (HI-POCT).

[26]  Jeremy Linskell Smart home technology and special needs reporting UK activity and sharing implemention experiences from Scotland , 2011, 2011 5th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth) and Workshops.

[27]  Kalju Meigas,et al.  New Photoplethysmographic Signal Analysis Algorithm for Arterial Stiffness Estimation , 2013, TheScientificWorldJournal.

[28]  Sujay Deb,et al.  Cuffless BP measurement using a correlation study of pulse transient time and heart rate , 2014, 2014 International Conference on Advances in Computing, Communications and Informatics (ICACCI).

[29]  A. Patzak,et al.  Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method , 2011, European Journal of Applied Physiology.

[30]  Wang Yi,et al.  Noninvasive and Continuous Blood Pressure Monitoring Using Wearable Body Sensor Networks , 2015, IEEE Intelligent Systems.

[31]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[32]  Dingchang Zheng,et al.  Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure. , 2009, Journal of biomechanics.

[33]  J. Ruiz-Rodríguez,et al.  Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology , 2013, Intensive Care Medicine.

[34]  Georges Delhomme,et al.  Wearable Electronic Systems: Applications to Medical Diagnostics/Monitoring , 2011 .

[35]  Amirhossein Esmaili,et al.  Nonlinear Cuffless Blood Pressure Estimation of Healthy Subjects Using Pulse Transit Time and Arrival Time , 2017, IEEE Transactions on Instrumentation and Measurement.

[36]  Mohammad Hassan Moradi,et al.  Cuffless Blood Pressure Estimation during Exercise Stress Test , 2012 .

[37]  Paul Rubel,et al.  Toward a Personal Health Society in Cardiology , 2010, IEEE Transactions on Information Technology in Biomedicine.

[38]  Maxime Cannesson,et al.  Non-invasive continuous blood pressure monitoring: a review of current applications , 2013, Frontiers of Medicine.

[39]  Jonghyun Park,et al.  Cuffless and Continuous Blood Pressure Monitoring Using a Single Chest-Worn Device , 2019, IEEE Access.

[40]  Nikolaos G. Bourbakis,et al.  A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[41]  Christopher M O'Connor,et al.  Treatment of Hypertension in Patients With Coronary Artery Disease: A Scientific Statement from the American Heart Association, American College of Cardiology, and American Society of Hypertension. , 2015, Journal of the American College of Cardiology.

[42]  R. Klabunde,et al.  Comprar Cardiovascular Physiology Concepts | Richard E. Klabunde | 9781451113846 | Lippincott Williams & Wilkins , 2011 .

[43]  Xuan Zeng,et al.  Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals , 2017, BioMedical Engineering OnLine.

[44]  Morbidity and Mortality Weekly Report , 2022 .

[45]  Junaidah Bte Mustafa Kamal.,et al.  Remote health monitoring. , 2013 .

[46]  Gourab Kundu,et al.  Intelligent Mobile Health Monitoring System (IMHMS) , 2009, eHealth.

[47]  K. Tucker,et al.  New Approaches in Hypertension Management: a Review of Current and Developing Technologies and Their Potential Impact on Hypertension Care , 2019, Current Hypertension Reports.

[48]  Hirokazu Tanaka,et al.  Blood pressure estimation from pulse wave velocity measured on the chest , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[49]  Ram Dantu,et al.  Cuffless Differential Blood Pressure Estimation Using Smart Phones , 2013, IEEE Transactions on Biomedical Engineering.

[50]  Heather T. Ma,et al.  A Blood Pressure Monitoring Method for Stroke Management , 2014, BioMed research international.

[51]  Ronald M. Aarts,et al.  Systolic blood pressure estimation using PPG and ECG during physical exercise , 2016, Physiological measurement.

[52]  Yadong Wang,et al.  Toward a Smartphone Application for Estimation of Pulse Transit Time , 2015, Sensors.

[53]  Zhi-Hong Mao,et al.  Cuff-free blood pressure estimation using pulse transit time and heart rate , 2014, 2014 12th International Conference on Signal Processing (ICSP).

[54]  L A Geddes,et al.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. 1. , 1969, Cardiovascular Research Center bulletin.

[55]  X. Aubert,et al.  Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[56]  H. Harry Asada,et al.  Wearable, Cuff-less PPG-Based Blood Pressure Monitor with Novel Height Sensor , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[57]  Yuan-Ting Zhang,et al.  Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation , 2017, Scientific Reports.

[58]  Reza Malekian,et al.  Body Sensor Network for Mobile Health Monitoring, a Diagnosis and Anticipating System , 2015, IEEE Sensors Journal.

[59]  Elif Derya Ubeyli,et al.  Feature extraction for analysis of ECG signals , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[60]  Norbert Noury,et al.  A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising? , 2014 .

[61]  J. Muehlsteff,et al.  Wearable body sensor network towards continuous cuff-less blood pressure monitoring , 2008, 2008 5th International Summer School and Symposium on Medical Devices and Biosensors.

[62]  R. Payne,et al.  Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. , 2006, Journal of applied physiology.

[63]  L A Geddes,et al.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii. , 1980, Journal of biomechanical engineering.

[64]  Roozbeh Jafari,et al.  BioWatch — A wrist watch based signal acquisition system for physiological signals including blood pressure , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[65]  Edmond Zahedi,et al.  A comparative review of blood pressure measurement methods using pulse wave velocity , 2014, 2014 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA).

[66]  Saso Koceski,et al.  Robotic Assistant for Elderly Care - Development and Evaluation , 2017, Int. J. Autom. Technol..

[67]  Ko Keun Kim,et al.  Nonintrusive biological signal monitoring in a car to evaluate a driver's stress and health state. , 2009, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[68]  H. B. Riley,et al.  Performance Study of Different Denoising Methods for ECG Signals , 2014, EUSPN/ICTH.

[69]  John A. Stankovic,et al.  Context-aware wireless sensor networks for assisted living and residential monitoring , 2008, IEEE Network.

[70]  Voicu Groza,et al.  Electrocardiogram-Assisted Blood Pressure Estimation , 2012, IEEE Transactions on Biomedical Engineering.

[71]  Peter Xiaoping Liu,et al.  Secondary Peak Detection of PPG Signal for Continuous Cuffless Arterial Blood Pressure Measurement , 2014, IEEE Transactions on Instrumentation and Measurement.

[72]  Youngjoon Chee,et al.  Development of a nonintrusive blood pressure estimation system for computer users. , 2007, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[73]  Xuan Zeng,et al.  A Machine Learning-Empowered System for Long-Term Motion-Tolerant Wearable Monitoring of Blood Pressure and Heart Rate With Ear-ECG/PPG , 2017, IEEE Access.

[74]  Christian Holz,et al.  Glabella: Continuously Sensing Blood Pressure Behavior using an Unobtrusive Wearable Device , 2017, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol..

[75]  Luis Enrique Mendoza,et al.  Relationship of blood pressure with the electrical signal of the heart using signal processing Relación entre la presión sanguínea y la señal eléctrica del corazón usando una señal de procesamiento , 2014 .

[76]  Yiannos Manoli,et al.  Implantable accelerometer system for the determination of blood pressure using reflected wave transit time , 2014 .

[77]  Gi-Ryon Kim,et al.  Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time , 2010 .

[78]  Younessi Heravi Mohammad Amin,et al.  A New Approach for Blood Pressure Monitoring based on ECG and PPG Signals by using Arti?cial Neural Networks , 2014 .

[79]  Shih-Chung Chen,et al.  A new estimate technology of non-invasive continuous blood pressure measurement based on electrocardiograph , 2016 .

[80]  Mehmet Rasit Yuce,et al.  A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time , 2015, Physiological measurement.

[81]  P. L. Marino,,et al.  The ICU book , 1991 .

[82]  J Melbin,et al.  Arterial tonometry: review and analysis. , 1983, Journal of biomechanics.

[83]  Mahdi Shabany,et al.  Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring , 2017, IEEE Transactions on Biomedical Engineering.

[84]  O. Postolache,et al.  Blood Pressure and Heart Rate Variabilities Estimation Using Ballistocardiography , 2009 .

[85]  H. Harry Asada,et al.  Cuffless Blood Pressure Monitoring Using Hydrostatic Pressure Changes , 2008, IEEE Transactions on Biomedical Engineering.

[86]  G. Mitchell,et al.  Arterial stiffness and hypertension. , 2014, Hypertension.

[87]  Huihui Li,et al.  Beat-to-beat ambulatory blood pressure estimation based on random forest , 2016, 2016 IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN).

[88]  Ramakrishna Mukkamala,et al.  Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference , 2016, Physiological reports.

[89]  J. Muehlsteff,et al.  Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: The impact of posture , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[90]  Dale Schuurmans,et al.  Detection of a and b waves in the acceleration photoplethysmogram , 2014, Biomedical engineering online.

[91]  M. Y. Mashor,et al.  Measuring of Systolic Blood Pressure Based On Heart Rate , 2008 .

[92]  Yacine Rezgui,et al.  Progress in ambient assisted systems for independent living by the elderly , 2016, SpringerPlus.

[93]  Lai-Man Po,et al.  Cuffless Blood Pressure Estimation Based on Photoplethysmography Signal and Its Second Derivative , 2017 .

[94]  T. Wibmer,et al.  Pulse transit time and blood pressure during cardiopulmonary exercise tests. , 2011, Physiological research.

[95]  Changyun Wen,et al.  Continuous and Noninvasive Measurement of Systolic and Diastolic Blood Pressure by One Mathematical Model with the Same Model Parameters and Two Separate Pulse Wave Velocities , 2011, Annals of Biomedical Engineering.

[96]  Geevarghese Titus,et al.  Photoplethysmogram (PPG) signal analysis and wavelet de-noising , 2014, 2014 Annual International Conference on Emerging Research Areas: Magnetics, Machines and Drives (AICERA/iCMMD).

[97]  E. Nemati,et al.  A wireless wearable ECG sensor for long-term applications , 2012, IEEE Communications Magazine.