Liquid chromatography/mass spectrometry in anabolic steroid analysis--optimization and comparison of three ionization techniques: electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization.

The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.

[1]  L. Lucentini,et al.  Quantitation of anabolic hormones and their metabolites in bovine serum and urine by liquid chromatography-tandem mass spectrometry. , 2000, Journal of chromatography. A.

[2]  Feimeng Zhou,et al.  Changes in bulk solution pH caused by the inherent controlled-current electrolytic process of an electrospray ion source , 1997 .

[3]  M. Donike,et al.  Metabolism of anabolic steroids in man: synthesis and use of reference substances for identification of anabolic steroid metabolites , 1993 .

[4]  B. Chung,et al.  Measurement of 19-nortestosterone and its esters in equine plasma by high-performance liquid chromatography with tandem mass spectrometry. , 2000, Rapid communications in mass spectrometry : RCM.

[5]  L. Bowers,et al.  Analytical advances in detection of performance-enhancing compounds. , 1997, Clinical chemistry.

[6]  H. Nakazawa,et al.  Determination of trenbolone and zeranol in bovine muscle and liver by liquid chromatography-electrospray mass spectrometry. , 2000, Journal of chromatography. A.

[7]  L. Lucentini,et al.  Confirmation of anabolic hormone residues in bovine blood by micro-HPLC-ion spray-tandem mass spectrometry , 1997 .

[8]  A. Bruins,et al.  Effect of multiple sprayers on dynamic range and flow rate limitations in electrospray and ionspray mass spectrometry , 1994 .

[9]  J. Barbosa,et al.  Direct determination of anabolic steroids in human urine by on-line solid-phase extraction/liquid chromatography/mass spectrometry. , 1996, Journal of mass spectrometry : JMS.

[10]  J. Henion,et al.  Determination of methandrostenolone and its metabolites in equine plasma and urine by coupled-column liquid chromatography with ultraviolet detection and confirmation by tandem mass spectrometry. , 1989, Journal of chromatography.

[11]  J. Henion,et al.  Direct determination of anabolic steroid conjugates in human urine by combined high-performance liquid chromatography and tandem mass spectrometry. , 1997, Journal of chromatography. B, Biomedical sciences and applications.

[12]  D. B. Gower,et al.  Anabolic steroids: Metabolism, doping and detection in equestrian and human sports , 1995 .

[13]  R. Draisci,et al.  Confirmatory analysis of residues of stanozolol and its major metabolite in bovine urine by liquid chromatography-tandem mass spectrometry. , 2001, Journal of chromatography. A.

[14]  W. Niessen,et al.  State-of-the-art in liquid chromatography-mass spectrometry. , 1999, Journal of chromatography. A.

[15]  Sanaullah,et al.  Direct measurement of steroid sulfate and glucuronide conjugates with high-performance liquid chromatography-mass spectrometry. , 1996, Journal of chromatography. B, Biomedical applications.

[16]  J. Rodgers,et al.  Biotransformation of 17-alkyl steroids in the equine: high-performance liquid chromatography-mass spectrometric and gas chromatography-mass spectrometric analysis of fluoxymesterone metabolites in urine samples. , 1997, Journal of chromatography. B, Biomedical sciences and applications.

[17]  P. Joos,et al.  Liquid chromatography-tandem mass spectrometry of some anabolic steroids. , 1999, Analytical Chemistry.

[18]  C. Rodríguez,et al.  Use of ion trap gas chromatography-tandem mass spectrometry for detection and confirmation of anabolic substances at trace levels in doping analysis. , 1997, Journal of chromatography. B, Biomedical sciences and applications.

[19]  D. Hill,et al.  Electrospray collision-induced dissociation of testosterone and testosterone hydroxy analogs. , 1999, Journal of mass spectrometry : JMS.

[20]  J. Henion,et al.  High-performance liquid chromatography/tandem mass spectrometry: its use for the identification of stanozolol and its major metabolites in human and equine urine. , 1990, Biomedical & environmental mass spectrometry.

[21]  H. D. De brabander,et al.  Determination of 16beta-hydroxystanozolol in urine and faeces by liquid chromatography-multiple mass spectrometry. , 2000, Journal of chromatography. A.

[22]  J. Segura,et al.  Electrospray mass spectrometry of testosterone esters: Potential for use in doping control , 1997, Steroids.