Accurate prediction of LTK treatments requires refined thermal corneal models which necessitate precise input parameters. The overall objective of this study was to provide detailed information on the spatiotemporal temperature profile of the corneal surface, during in-vitro thermal keratoplasty. LTK was performed in-vitro on freshly harvested porcine eyes (N equals 16) with the Sunrise Technologies corneal shaping system (Model SUN 1000). Spatiotemporal thermal imaging of the irradiated corneas were obtained with a short wave Inframetrics thermal camera (Model PM290). Images were obtained at 8-bits resolution, with ~100 microns spatial and ~17 msec temporal resolution respectively. Treatment pattern consisted of eight spots at 6 mm zone, while lasing was conducted at settings of either 100 mJ and 15 pulses (N equals 8), or 260 mJ and 7 pulses (N equals 8). Temporal and spatial variation of the corneal surface temperatures were calculated at locations of importance to LTK. At the laser spot, temperature profiles consisted of transients coinciding approximately with the laser pulses. Maximum transient temperatures observed were 98.0+/- 4.6 degree(s)C for the high and 56.3+/- 2.6 degree(s)C for the low energy respectively. These temperature transients were superimposed on an envelope of lower-slowly varying temperatures. The maximum temperatures observed for this temperature envelope, were 51.8+/- 3.4 degree(s)C for the high and 35.4+/- 3.4 degree(s)C for the low energy respectively. The evolution of either the maximum temperature transients or the lower temperature envelope, followed exponential growth of the form: T equals A * exp(B*t). Maximum temperatures at locations 0.5 mm and 1 mm away from the laser spot, reached 25.7 degree(s)C and 23.3 degree(s)C for the low energy, and 34 degree(s)C and 25.6 degree(s)C for the high energy settings respectively. Temperature decay constants were approximately 2 to 3 sec, while the spatial temperature profile at the laser spot extended more than 2 mm at 2.5 sec post irradiation. The data obtained may help to refine corneal thermal modeling during LTK, and thus improve predictability of current or future-modified-treatments.
[1]
R Birngruber,et al.
Influence of temperature and time on thermally induced forces in corneal collagen and the effect on laser thermokeratoplasty.
,
2000,
Journal of cataract and refractive surgery.
[2]
R. Birngruber,et al.
Thermal and Biomechanical Parameters of Porcine Cornea
,
2000,
Cornea.
[3]
Qiushi Ren,et al.
Thermal modeling of laser photothermo keratoplasty
,
1992,
Photonics West - Lasers and Applications in Science and Engineering.
[4]
T Kohnen,et al.
Hyperopia correction by noncontact holmium:YAG laser thermal keratoplasty: U.S. phase IIA clinical study with 2-year follow-up.
,
1997,
Ophthalmology.
[5]
Fabrice Manns,et al.
Infrared measurement of thermal constants in laser-irradiated scleral tissue
,
1996,
Photonics West.