The TVT Glass Pavilion: Theoretical Study on a Highly Transparent Building Made with Long-Spanned TVT Portals Braced with Hybrid Glass-Steel Panels

In contemporary buildings, the architectural demand for a complete dematerialisation of load bearing structures can be satisfied only in limited cases with the exclusive structural use of glass. Otherwise, for challenging applications such as long spanned or high-rise structures, the use of hybrid glass-steel systems is mandatory. Glass, fragile but highly compressive resistant, is associated with steel, ductile and tensile resistant. The present research shows the feasibility study for a fully glazed pavilion made of six TVT (Travi Vitree Tensegrity) portal frames longitudinally braced by pre-stressed hybrid glass panels. The frames are about 20 m in span and 8 m in height. Appropriate multiscalar FEM numerical analyses, calibrated on the collapse tests performed on previous TVT large-scale prototypes, stated that the structural performance would be able to withstand heavy static and dynamic loads and stated the observance of the Fail-Safe Design principles.

[1]  Hans Schober,et al.  Developments in Structural Glass and Glass Structures , 2004 .

[2]  van F Frans Herwijnen,et al.  Glass panes acting as shear wall , 2007 .

[3]  Jean-Paul Lebet,et al.  Exploratory experimental investigations on post-tensioned structural glass beams , 2013 .

[4]  Chiara Bedon,et al.  Finite Element analysis of post-tensioned SG-laminated glass beams with adhesively bonded steel tendons , 2017 .

[5]  Aldina Santiago,et al.  Behaviour of laminated glass beams reinforced with pre‐stressed cables , 2014 .

[6]  Paolo Spinelli,et al.  Static and dynamic response of progressively damaged ionoplast laminated glass beams , 2016 .

[7]  Maurizio Froli,et al.  The energy gallery: a pilot project in Pisa , 2014 .

[8]  Bernhard Weller,et al.  Post-Tensioned Glass Beams for a 9 m Spannglass Bridge , 2016 .

[9]  D Antolinc,et al.  Simulation of earthquake load imposed on timber-glass composite shear wall panel , 2013 .

[10]  Maurizio Orlando,et al.  Long term response of glass–PVB double-lap joints , 2014 .

[11]  Jan Belis Glass structures, from theory to practice , 2013 .

[12]  B N. Free-form , form finding and anisotropic grid shell , 2009 .

[13]  Jan Belis,et al.  Numerical investigation of two-sided reinforced laminated glass beams in statically indeterminate systems , 2016 .

[14]  Thomas Wever,et al.  Glass-reinforced steel structures , 2016 .

[15]  Alberto Domingo Cabo,et al.  Evolution and Trends in Design, Analysis and Construction of Shell and Spatial Structures , 2009 .

[16]  Jan Belis,et al.  Load-carrying behaviour of interrupted statically indeterminate reinforced laminated glass beams , 2016 .

[17]  Frank Wellershoff Nutzung der Verglasung zur Aussteifung von Gebäudehüllen , 2006 .

[18]  Chiara Bedon,et al.  Finite-element analysis of post-tensioned SG-laminated glass beams with mechanically anchored tendons , 2016 .

[19]  Marcin Kozëowski,et al.  Hybrid glass beams. Review of research projects and applications , 2012 .

[20]  Maurizio Froli,et al.  Glass Tensegrity Trusses , 2010 .

[21]  Ye Jihong,et al.  A New Type of Structure: Glass Cable Truss , 2015 .

[22]  Miroslav Premrov,et al.  Racking resistance of timber-glass wall elements using different types of adhesives , 2015 .

[23]  M. Froli,et al.  A 12 meter long segmented post-tensioned steel-glass beam (TVT Gamma) , 2014 .

[24]  Jan Belis,et al.  Experimental investigation of multi-span post-tensioned glass beams , 2017 .

[25]  Thomas Vogel,et al.  Load-bearing behavior of spliced glass beams under bending action , 2016 .

[26]  Jan Belis,et al.  Structural response of SG-laminated reinforced glass beams; experimental investigations on the effects of glass type, reinforcement percentage and beam size , 2012 .