DFIG virtual inertia control in micro-grid based on setting trigger condition and ZN method for parameters optimisation

The virtual inertia control (VIC) is used to design frequency regulation for a doubly fed induction generator (DFIG). The VIC method can be improved by adding supplementary control loops for inertia response and rotor speed recovery. In this study, certain delay time of the recovery module is replaced by setting a trigger condition to make the speed recover. Then the modified Ziegler–Nichols (ZN) method is used to calculate proportional–integral parameters of the recovery module quickly and accurately. Finally, the VIC method is applied to the micro-grid switch grid-connected mode to unplanned island mode. Simulation results demonstrate that the modified VIC method is effective to improve transient stability for the micro-gird during switching mode.

[1]  Li Sun,et al.  On Inertial Dynamics of Virtual-Synchronous-Controlled DFIG-Based Wind Turbines , 2015, IEEE Transactions on Energy Conversion.

[2]  Qiu Jia-ju Frequency Control Strategy of Variable-speed Constant-frequency Doubly-fed Induction Generator Wind Turbines , 2009 .

[3]  Jin-Ming Lin,et al.  Coordinated frequency regulation by doubly fed induction generator-based wind power plants , 2012 .

[4]  Hongfeng Li,et al.  European town microgrid and energy storage application study , 2013, 2013 IEEE PES Innovative Smart Grid Technologies Conference (ISGT).

[5]  Xiaorong Zhu,et al.  Virtual inertia control of DFIG-based wind turbines for dynamic grid frequency support , 2011 .

[6]  Joe H. Chow,et al.  A Fundamental Study of Applying Wind Turbines for Power System Frequency Control , 2016, IEEE Transactions on Power Systems.

[7]  M. C. Chandorkar,et al.  Improvement of Transient Response in Microgrids Using Virtual Inertia , 2013, IEEE Transactions on Power Delivery.

[8]  J.A. Ferreira,et al.  Wind turbines emulating inertia and supporting primary frequency control , 2006, IEEE Transactions on Power Systems.

[9]  Cheng Luo,et al.  Participation of large-scale wind power generation in power system frequency regulation , 2013 .

[10]  João Carlos Basilio,et al.  Design of PI and PID controllers with transient performance specification , 2002, IEEE Trans. Educ..

[11]  D. Seborg,et al.  Multiloop PI/PID controller design based on Gershgorin bands , 2001 .

[12]  Lie Xu,et al.  Control of PMSG-Based Wind Turbines for System Inertial Response and Power Oscillation Damping , 2015, IEEE Transactions on Sustainable Energy.

[13]  Mei Shengwei,et al.  Control strategy and application of power converter system in battery energy storage system , 2014, IEEE PES Innovative Smart Grid Technologies, Europe.

[14]  Li Guo,et al.  A seamless operation mode transition control strategy for a microgrid based on master-slave control , 2012, Proceedings of the 31st Chinese Control Conference.

[15]  Zheng Xu,et al.  Coordinated control of wind farm and VSC–HVDC system using capacitor energy and kinetic energy to improve inertia level of power systems , 2014 .

[16]  Ehab F. El-Saadany,et al.  Implementing Virtual Inertia in DFIG-Based Wind Power Generation , 2013, IEEE Transactions on Power Systems.

[17]  Zhiheng Zhang,et al.  Comparison of inertia control methods for DFIG-based wind turbines , 2013, 2013 IEEE ECCE Asia Downunder.

[18]  Wang Bo,et al.  Control strategy for micro grid transfer between in-grid and short-time islanded states based on flywheel storage , 2013, Proceedings of the 32nd Chinese Control Conference.

[19]  Cheng Guo,et al.  Research on DFIGs' participation in frequency regulation and penetration ratio of wind power integration , 2014, 2014 International Conference on Power System Technology.

[20]  Paul Giorsetto,et al.  Development of a New Procedure for Reliability Modeling of Wind Turbine Generators , 1983, IEEE Transactions on Power Apparatus and Systems.

[21]  Emilio Gomez-Lazaro,et al.  Demand-Side Contribution to Primary Frequency Control With Wind Farm Auxiliary Control , 2014, IEEE Transactions on Power Systems.

[22]  Fangxing Li,et al.  Coordinated Microgrid Frequency Regulation Based on DFIG Variable Coefficient Using Virtual Inertia and Primary Frequency Control , 2016, IEEE Transactions on Energy Conversion.

[23]  Ashwani Kumar,et al.  Dynamic contribution of variable-speed wind energy conversion system in system frequency regulation , 2012 .

[24]  E. F. El-Saadany,et al.  Incorporating DFIG based wind power generation in microgrid frequency regulation , 2012, 2012 IEEE Power and Energy Society General Meeting.

[25]  Badrul H. Chowdhury,et al.  Working towards frequency regulation with wind plants: Combined control approaches , 2010 .

[26]  Yi Wang,et al.  A novel method for obtaining virtual inertial response of DFIG‐based wind turbines , 2016 .

[27]  David Clarke Pretuning and adaptation of PI controllers , 2003 .

[28]  Luiz A. C. Lopes,et al.  An optimal virtual inertia controller to support frequency regulation in autonomous diesel power systems with high penetration of renewables , 2011 .

[29]  Sasongko Pramono Hadi,et al.  Optimal configuration of PV-Wind turbine-grid-battery in low potency energy resources , 2014, 2014 6th International Conference on Information Technology and Electrical Engineering (ICITEE).