Background culturable bacteria aerosol in two large public buildings using HVAC filters as long term, passive, high-volume air samplers.

Background culturable bacteria aerosols were collected and identified in two large public buildings located in Minneapolis, Minnesota and Seattle, Washington over a period of 5 months and 3 months, respectively. The installed particulate air filters in the ventilation systems were used as the aerosol sampling devices at each location. Both pre and final filters were collected from four air handing units at each site to determine the influence of location within the building, time of year, geographical location and difference between indoor and outdoor air. Sections of each loaded filter were eluted with 10 ml of phosphate buffered saline (PBS). The resulting solutions were cultured on blood agar plates and incubated for 24 h at 36 degrees C. Various types of growth media were then used for subculturing, followed by categorization using a BioLog MicroStation (Biolog, Hayward, CA, USA) and manual observation. Environmental parameters were gathered near each filter by the embedded on-site environmental monitoring systems to determine the effect of temperature, humidity and air flow. Thirty nine different species of bacteria were identified, 17 found only in Minneapolis and 5 only in Seattle. The hardy spore-forming genus Bacillus was the most commonly identified and showed the highest concentrations. A significant decrease in the number of species and their concentration occurred in the Minneapolis air handling unit supplying 100% outdoor air in winter, however no significant correlations between bacteria concentration and environmental parameters were found.

[1]  K W Tham,et al.  Size relationship between airborne viable bacteria and particles in a controlled indoor environment study. , 2005, Indoor air.

[2]  Petros Koutrakis,et al.  Determining the infiltration of outdoor particles in the indoor environment using a dynamic model , 2006 .

[3]  Robert B. Simmons,et al.  Mold colonization during use of preservative-treated and untreated air filters, including HEPA filters from hospitals and commercial locations over an 8-year period (1996–2003) , 2005, Journal of Industrial Microbiology and Biotechnology.

[4]  Tiina Reponen,et al.  Control of aerosol contaminants in indoor air: combining the particle concentration reduction with microbial inactivation. , 2007, Environmental science & technology.

[5]  Alan M. Jones,et al.  The effects of meteorological factors on atmospheric bioaerosol concentrations--a review. , 2004, The Science of the total environment.

[6]  Xiao‐Ru Wang,et al.  Detection and Quantification of Wallemia sebi in Aerosols by Real-Time PCR, Conventional PCR, and Cultivation , 2004, Applied and Environmental Microbiology.

[7]  Chihshan Li,et al.  Sampling Performance for Bioaerosols by Flow Cytometry with Fluorochrome , 2005 .

[8]  A. Awad Airborne dust, bacteria, actinomycetes and fungi at a flourmill , 2007 .

[9]  S. Miller,et al.  Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons. , 2006, Indoor air.

[10]  B. Lighthart Microbial Aerosols: Estimated Contribution of Combine Harvesting to an Airshed , 1984, Applied and environmental microbiology.

[11]  Peter C Raynor,et al.  Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters. , 2006, Journal of environmental monitoring : JEM.

[12]  Patricia Cruz,et al.  Determination of the Efficacy of Two Building Decontamination Strategies by Surface Sampling with Culture and Quantitative PCR Analysis , 2004, Applied and Environmental Microbiology.

[13]  Tiina Reponen,et al.  Long-term sampling of airborne bacteria and fungi into a non- evaporating liquid , 1999 .

[14]  J M Macher,et al.  Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study. , 2005, Indoor air.

[15]  M. Möritz,et al.  Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems. , 2001, International journal of hygiene and environmental health.

[16]  Chihshan Li,et al.  Fluorochrome in Monitoring Indoor Bioaerosols , 2006 .

[17]  C. Gerba,et al.  Bioaerosol Transport Modeling and Risk Assessment in Relation to Biosolid Placement , 2000, Journal of Environmental Quality.

[18]  Patricia Cruz,et al.  Detection and enumeration of airborne biocontaminants. , 2004, Current opinion in biotechnology.

[19]  J. Seinfeld,et al.  Effect of Angle of Attack on the Performance of an Airborne Counterflow Virtual Impactor , 2005 .

[20]  B. Lighthart,et al.  The Annual Bacterial Particle Concentration and Size Distribution in the Ambient Atmosphere in a Rural Area of the Willamette Valley, Oregon , 2000 .

[21]  Tiina Reponen,et al.  Survival of Airborne Microorganisms During Swirling Aerosol Collection , 2000 .

[22]  D. Pierson,et al.  Fungal Colonization of Air Filters and Insulation in a Multi-Story Office Building: Production of Volatile Organics , 1997, Current Microbiology.

[23]  K. Strevett,et al.  Bioaerosol Concentration at an Outdoor Composting Center. , 1999, Journal of the Air & Waste Management Association.

[24]  Philip H. Jones,et al.  Sampling and differentiation techniques for airborne organisms emitted from wastewater , 1979 .

[25]  Britt A. Holmén,et al.  Lidar-assisted measurement of PM10 emissions from agricultural tilling in California's San Joaquin Valley – Part II: emission factors , 2001 .

[26]  P. C. Kemp,et al.  Survival and growth of micro-organisms on air filtration media during initial loading , 2001 .

[27]  Shelly L. Miller,et al.  Ambient bioaerosol indices for indoor air quality assessments of flood reclamation , 2005 .

[28]  R. Roffey,et al.  Long-range air transmission of bacteria , 1978, Applied and environmental microbiology.

[29]  J. Peccia,et al.  Estimating solar and nonsolar inactivation rates of airborne bacteria , 2004 .

[30]  Mark Hernandez,et al.  Effects of Ceiling-Mounted HEPA-UV Air Filters on Airborne Bacteria Concentrations in an Indoor Therapy Pool Building , 2005, Journal of the Air & Waste Management Association.

[31]  K. R. Pagilla,et al.  Time and Space Uniformity of Indoor Bacteria Concentrations in Chicago Area Residences , 2003 .

[32]  P. Thorne,et al.  Bioaerosol Concentrations in Noncomplaint, Complaint, and Intervention Homes in the Midwest , 1995 .

[33]  J. Cookson,et al.  Natural atmospheric microbial conditions in a typical suburban area , 1983, Applied and environmental microbiology.

[34]  L. Elfman,et al.  Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools--associations with asthma and respiratory symptoms in pupils. , 2007, Indoor air.

[35]  Jozef S. Pastuszka,et al.  Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland , 2000 .

[36]  Jacek Dutkiewicz,et al.  Size distribution of bacterial and fungal bioaerosols in indoor air. , 1999, Annals of agricultural and environmental medicine : AAEM.

[37]  R. Maus,et al.  Survival of bacterial and mold spores in air filter media , 2001 .

[38]  W. Jo,et al.  Workplace exposure to bioaerosols in pet shops, pet clinics, and flower gardens. , 2006, Chemosphere.

[39]  R. Simmons,et al.  Fungal colonization of air filters for use in heating, ventilating, and air conditioning (HVAC) systems , 2005, Journal of Industrial Microbiology.

[40]  M. Verdenelli,et al.  Efficacy of antimicrobial filter treatments on microbial colonization of air panel filters , 2003, Journal of applied microbiology.

[41]  Y. C. Lin,et al.  Storage effects on bacterial concentration: determination of impinger and filter samples. , 2001, The Science of the total environment.

[42]  Chihshan Li,et al.  Quantification of Airborne Mycobacterium tuberculosis in Health Care Setting Using Real-Time qPCR Coupled to an Air-Sampling Filter Method , 2005 .

[43]  C. Kuske Current and emerging technologies for the study of bacteria in the outdoor air. , 2006, Current opinion in biotechnology.

[44]  Maosheng Yao,et al.  Use of portable microbial samplers for estimating inhalation exposure to viable biological agents , 2007, Journal of Exposure Science and Environmental Epidemiology.

[45]  S. Pillai,et al.  Occurrence of airborne bacteria and pathogen indicators during land application of sewage sludge , 1996, Applied and environmental microbiology.

[46]  Huang-Min Liang,et al.  Temporal/seasonal variations of size-dependent airborne fungi indoor/outdoor relationships for a wind-induced naturally ventilated airspace , 2004 .

[47]  R. Simmons,et al.  Fungal colonization of air filters from hospitals. , 1997, American Industrial Hygiene Association journal.

[48]  B. Szponar,et al.  Microorganisms and volatile organic compounds in airborne dust from damp residences. , 2004, Indoor air.

[49]  Thomas H. Kuehn,et al.  Airborne infection control in health care facilities , 2003 .