Ultrasonic technique for imaging tissue vibrations: preliminary results.

We propose an ultrasound (US)-based technique for imaging vibrations in the blood vessel walls and surrounding tissue caused by eddies produced during flow through narrowed or punctured arteries. Our approach is to utilize the clutter signal, normally suppressed in conventional color flow imaging, to detect and characterize local tissue vibrations. We demonstrate the feasibility of visualizing the origin and extent of vibrations relative to the underlying anatomy and blood flow in real-time and their quantitative assessment, including measurements of the amplitude, frequency and spatial distribution. We present two signal-processing algorithms, one based on phase decomposition and the other based on spectral estimation using eigen decomposition for isolating vibrations from clutter, blood flow and noise using an ensemble of US echoes. In simulation studies, the computationally efficient phase-decomposition method achieved 96% sensitivity and 98% specificity for vibration detection and was robust to broadband vibrations. Somewhat higher sensitivity (98%) and specificity (99%) could be achieved using the more computationally intensive eigen decomposition-based algorithm. Vibration amplitudes as low as 1 mum were measured accurately in phantom experiments. Real-time tissue vibration imaging at typical color-flow frame rates was implemented on a software-programmable US system. Vibrations were studied in vivo in a stenosed femoral bypass vein graft in a human subject and in a punctured femoral artery and incised spleen in an animal model.

[1]  W. M. Carey,et al.  Digital spectral analysis: with applications , 1986 .

[2]  J. Kostis,et al.  Coronary Artery Disease - Correlates Between Diastolic Auditory Characteristics and Coronary Artery Stenoses , 1983, IEEE Transactions on Biomedical Engineering.

[3]  R. Martin,et al.  Hemostasis of punctured vessels using Doppler-guided high-intensity ultrasound. , 1999, Ultrasound in medicine & biology.

[4]  Melani Plett Ultrasonic arterial vibrometry with wavelet based detection and estimation , 2000 .

[5]  R. Lees,et al.  Phonoangiography: a new noninvasive diagnostic method for studying arterial disease. , 1970, Proceedings of the National Academy of Sciences of the United States of America.

[6]  B. Hofmann-Wellenhof,et al.  Introduction to spectral analysis , 1986 .

[7]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[8]  J.L. Semmlow,et al.  Noninvasive acoustical detection of coronary artery disease: a comparative study of signal processing methods , 1993, IEEE Transactions on Biomedical Engineering.

[9]  E. Boyko,et al.  Physical examination and chronic lower-extremity ischemia: a critical review. , 1998, Archives of internal medicine.

[10]  V. Shamdasani,et al.  Ultrasound color-flow imaging on a programmable system , 2004, IEEE Transactions on Information Technology in Biomedicine.

[11]  D. Winestock,et al.  The clinical indications for arteriography in trauma to the extremity. A review of 114 cases. , 1975, Radiology.

[12]  W. Walker,et al.  A fundamental limit on the performance of correlation based phase correction and flow estimation techniques , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  F. Albers,et al.  Clinical characteristics of atherosclerotic renovascular disease. , 1994, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[14]  R. Lees,et al.  Evaluation of carotid stenosis by phonoangiography. , 1975, The New England journal of medicine.

[15]  W D Middleton,et al.  Perivascular color artifact: pathologic significance and appearance on color Doppler US images. , 1989, Radiology.

[16]  N. Chubachi,et al.  Transcutaneous measurement and spectrum analysis of heart wall vibrations , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  J A Jensen,et al.  A model for the propagation and scattering of ultrasound in tissue. , 1991, The Journal of the Acoustical Society of America.

[18]  O. Bonnefous,et al.  New TDI developments for vascular and cardiac applications , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[19]  Kevin J. Parker,et al.  Time domain Doppler estimators of the amplitude of vibrating targets , 1992 .

[20]  Tetsuya Hayashi,et al.  A single mediaprocessor-based programmable ultrasound system , 2003, IEEE Transactions on Information Technology in Biomedicine.

[21]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[22]  D. E. Strandness,et al.  Quantitative carotid phonoangiography. , 1981, Stroke.

[23]  Y. Yamakoshi,et al.  Ultrasonic imaging of internal vibration of soft tissue under forced vibration , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  H. Torp,et al.  Ultrasound doppler measurements of low velocity blood flow: limitations due to clutter signals from vibrating muscles , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  K. Hutchison,et al.  Arterial Wall Vibration Distal to Stenoses in Isolated Arteries of Dog and Man , 1970, Circulation research.

[26]  N R Cholvin,et al.  Wall vibrations induced by flow through simulated stenosis in models and arteries. , 1977, Journal of biomechanics.