A single microphone capillary-based system for measuring the complex input impedance of musical wind instruments

Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe.

[1]  H. Saunders,et al.  Fundamentals of Acoustics (3rd Ed.) , 1983 .

[2]  J. Wolfe,et al.  Acoustic impedance measurements-correction for probe geometry mismatch. , 2005, The Journal of the Acoustical Society of America.

[3]  John Backus,et al.  Input impedance curves for the reed woodwind instruments , 1974 .

[4]  Maarten van Walstijn,et al.  Wideband measurement of the acoustic impedance of tubular objects , 2005 .

[5]  John Backus Acoustic impedance of an annular capillary , 1975 .

[6]  Heinrich Pichler,et al.  BIAS: A Computer-Aided Test System for Brass Wind Instruments , 1989 .

[7]  Wilfried Kausel Bore reconstruction of tubular ducts from its acoustic input impedance curve , 2004, IEEE Transactions on Instrumentation and Measurement.

[8]  Arthur H. Benade,et al.  Survey of impedance methods and a new piezo‐disk‐driven impedance head for air columns , 1987 .

[9]  J. L. Roux,et al.  A new impedance sensor for wind instruments , 2008 .

[10]  A. H. Benade,et al.  Impedance measurement source and microphone proximity effects , 1980 .

[11]  Gregor Widholm,et al.  Brass wind instrument quality measured and evaluated by a new computer system , 1995 .

[12]  Joe Wolfe,et al.  Improved precision in measurements of acoustic impedance spectra using resonance-free calibration loads and controlled error distribution. , 2007, The Journal of the Acoustical Society of America.

[13]  Lawrence E. Kinsler,et al.  Fundamentals of acoustics , 1950 .

[14]  Vincent Gibiat,et al.  Acoustical impedance measurements by the two‐microphone‐three‐calibration (TMTC) method , 1990 .

[15]  John Backus,et al.  Input impedance curves for the brass instruments , 1976 .

[16]  W. Winkler,et al.  Evaluation of musical instrument quality by computer systems. Examples of realisation , 1994 .

[17]  J. Dalmont,et al.  ACOUSTIC IMPEDANCE MEASUREMENT, PART I: A REVIEW , 2001 .

[19]  A. Locke,et al.  The effect of the evanescent wave upon acoustic measurements in the human ear canal. , 1997, The Journal of the Acoustical Society of America.

[20]  René Causse,et al.  Measurement of acoustic impedance using a capillary: An attempt to achieve optimization , 1986 .

[21]  D Murray Campbell,et al.  Time domain wave separation using multiple microphones. , 2010, The Journal of the Acoustical Society of America.

[22]  René Causse,et al.  Input impedance of brass musical instruments—Comparison between experiment and numerical models , 1984 .