Comparison of 3D finite element analysis derived stiffness and BMD to determine the failure load of the excised proximal femur.

INTRODUCTION Bone mineral density (BMD) is currently the preferred surrogate for bone strength in clinical practice. Finite element analysis (FEA) is a computer simulation technique that can predict the deformation of a structure when a load is applied, providing a measure of stiffness (N mm(-1)). Finite element analysis of X-ray images (3D-FEXI) is a FEA technique whose analysis is derived from a single 2D radiographic image. METHODS 18 excised human femora had previously been quantitative computed tomography scanned, from which 2D BMD-equivalent radiographic images were derived, and mechanically tested to failure in a stance-loading configuration. A 3D proximal femur shape was generated from each 2D radiographic image and used to construct 3D-FEA models. RESULTS The coefficient of determination (R(2)%) to predict failure load was 54.5% for BMD and 80.4% for 3D-FEXI. CONCLUSIONS This ex vivo study demonstrates that 3D-FEXI derived from a conventional 2D radiographic image has the potential to significantly increase the accuracy of failure load assessment of the proximal femur compared with that currently achieved with BMD. This approach may be readily extended to routine clinical BMD images derived by dual energy X-ray absorptiometry.

[1]  Volker Kuhn,et al.  Reproducibility and Side Differences of Mechanical Tests for Determining the Structural Strength of the Proximal Femur , 2003, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[2]  Jamshid Tehranzadeh,et al.  Predicting Proximal Femoral Strength Using Structural Engineering Models , 2005, Clinical orthopaedics and related research.

[3]  J. Tehranzadeh,et al.  Mechanical properties, density and quantitative CT scan data of trabecular bone with and without metastases. , 2004, Journal of biomechanics.

[4]  J H Keyak,et al.  Automated three-dimensional finite element modelling of bone: a new method. , 1990, Journal of biomedical engineering.

[5]  W. Hayes,et al.  Fracture prediction for the proximal femur using finite element models: Part II--Nonlinear analysis. , 1991, Journal of biomechanical engineering.

[6]  N. Dalén,et al.  Bone mineral content and mechanical strength of the femoral neck. , 1976, Acta orthopaedica Scandinavica.

[7]  David Mitton,et al.  Assessment of femoral neck strength by 3-dimensional X-ray absorptiometry. , 2006, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[8]  R. Putz,et al.  Correlation of Femoral and Lumbar DXA and Calcaneal Ultrasound, Measured In Situ with Intact Soft Tissues, with the In Vitro Failure Loads of the Proximal Femur , 1998, Osteoporosis International.

[9]  S. Goldstein,et al.  Femoral strength is better predicted by finite element models than QCT and DXA. , 1999, Journal of biomechanics.

[10]  D. Cody,et al.  Femoral structure and stiffness in patients with femoral neck fracture , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  T. Lim,et al.  Poroelastic properties of bovine vertebral trabecular bone , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  A. Prescher,et al.  Short communication Concept and development of an orthotropic FEmodel of the proximal femur , 2003 .

[13]  J. Keyak,et al.  Generation of a 3D proximal femur shape from a single projection 2D radiographic image , 2009, Osteoporosis International.

[14]  J. Keyak,et al.  Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load. , 2003, Medical engineering & physics.

[15]  C. Langton,et al.  Sensitivity of proximal femoral stiffness and areal bone mineral density to changes in bone geometry and density , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[16]  J H Keyak,et al.  Estimation of material properties in the equine metacarpus with use of quantitative computed tomography , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  J. Keyak Improved prediction of proximal femoral fracture load using nonlinear finite element models. , 2001, Medical engineering & physics.

[18]  H. Skinner,et al.  Prediction of femoral fracture load using automated finite element modeling. , 1997, Journal of biomechanics.

[19]  Alan W Eberhardt,et al.  Bone mineral density correlates with fracture load in experimental side impacts of the pelvis. , 2003, Journal of biomechanics.

[20]  H K Genant,et al.  Osteoporosis. Current techniques and recent developments in quantitative bone densitometry. , 1991, Radiologic clinics of North America.

[21]  G U Rao,et al.  Predicting femoral neck strength from bone mineral data. A structural approach. , 1990, Investigative radiology.