Removal of a fractured locator abutment screw fragment.

BACKGROUND Although, dental implants have been a predictable option to support several types of restorations, mechanical problems are not uncommon. Retaining and abutment screw loosenings/fractures are one of the most common technical problems. AIM To present a step-by-step technique in order to remove a broken locater abutment screw fragment. MATERIALS AND METHODS A 56-year-old, edentulous man with a fractured locator abutment screw in an implant was referred to our clinic from a private practice. His dentist placed a narrow platform locator abutment onto a regular platform implant and the fracture occurred. Attempts to remove the fractured fragment using a periodontal probe and a manual screw removal driver were unsuccessful. RESULTS This clinical report presents a situation in which a fractured locater abutment screw fragment was successfully removed using an implant repair kit. CONCLUSION A fractured locater abutment screw fragment was successfully removed using an implant repair kit including drills, drill guides and tapping instruments. To avoid similar complications, it is recommended to use appropriate manufacturer specified torque values in conjunction with compatible restorative components. CLINICAL SIGNIFICANCE Retaining and abutment screw loosenings/fractures are one of the most common mechanical problems associated with the implant components. This clinical report showed how to remove a broken screw fragment using proper armamentarium and technique, which might help clinicians eliminate similar problems.

[1]  S G Vermilyea,et al.  Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. , 1994, The International journal of oral & maxillofacial implants.

[2]  P. Noritomi,et al.  Evaluation of stress distribution in overdenture-retaining bar with different levels of vertical misfit. , 2011, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[3]  F G Robinson,et al.  Retrieval technique for fractured implant screws. , 2001, The Journal of prosthetic dentistry.

[4]  I. Nergiz,et al.  Removal of a fractured implant abutment screw: a clinical report. , 2004, The Journal of prosthetic dentistry.

[5]  I. Turkyilmaz,et al.  A 4-year prospective clinical and radiological study of maxillary dental implants supporting single-tooth crowns using early and delayed loading protocols. , 2007, Clinical implant dentistry and related research.

[6]  K. Tan,et al.  Load fatigue performance of a single-tooth implant abutment system: effect of diameter. , 2006, The International journal of oral & maxillofacial implants.

[7]  C. Goodacre,et al.  Clinical complications with implants and implant prostheses. , 2003, The Journal of prosthetic dentistry.

[8]  N. Lang,et al.  Fractured prosthetic abutments in osseointegrated implants: a technical complication to cope with. , 2000, Clinical oral implants research.

[9]  S Winkler,et al.  The effect of implant diameter, restoration design, and occlusal table variations on screw loosening of posterior single-tooth implant restorations. , 2001, The Journal of oral implantology.

[10]  M S Schwarz,et al.  Mechanical complications of dental implants. , 2000, Clinical oral implants research.

[11]  R L Sakaguchi,et al.  Elongation and preload stress in dental implant abutment screws. , 1995, The International journal of oral & maxillofacial implants.

[12]  Bjarni E Pjetursson,et al.  A systematic review of the survival and complication rates of resin-bonded bridges after an observation period of at least 5 years , 2008, BDJ.

[13]  S E Eckert,et al.  Analysis of incidence and associated factors with fractured implants: a retrospective study. , 2000, The International journal of oral & maxillofacial implants.

[14]  Hom-lay Wang,et al.  Biomechanical implant treatment complications: a systematic review of clinical studies of implants with at least 1 year of functional loading. , 2012, The International journal of oral & maxillofacial implants.

[15]  Hiok Chai Quek,et al.  Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system. , 2008, The International journal of oral & maxillofacial implants.

[16]  J. Satterthwaite,et al.  Retrieval of a fractured abutment screw thread from an implant: a case report , 2008, BDJ.

[17]  John D. Jones,et al.  Long term success of 6 implants supporting a mandibular screw-retained fixed dental prosthesis: a clinical report. , 2012, The Journal of prosthetic dentistry.

[18]  Gabor Tepper,et al.  A 5-year prospective multicenter study on 1-stage smooth-surface Brånemark System implants with early loading in edentulous mandibles. , 2008, The International journal of oral & maxillofacial implants.