Design of the MEMS Piezoresistive Electronic Heart Sound Sensor

This paper proposes the electronic heart sound sensor, based on the piezoresistive principle and MEMS (Micro-Electro-Mechanical System) technology. Firstly, according to the characteristics of heart sound detection, the double-beam-block microstructure has been proposed, and the theoretical analysis and finite element method (FEM) simulation have been carried out. Combined with the natural frequency response of the heart sound (20~600 Hz), its structure sizes have been determined. Secondly, the processing technology of the microstructure with the stress concentration grooves has been developed. The material and sizes of the package have been determined by the three-layer medium transmission principle. Lastly, the MEMS piezoresistive electronic heart sound sensor has been tested compared with the 3200-type electronic stethoscope from 3M (São Paulo, MN, USA). The test results show that the heart sound waveform tested by the MEMS electronic heart sound sensor are almost the same as that tested by the 3200-type electronic stethoscope. Moreover, its signal-to-noise ratio is significantly higher. Compared with the traditional stethoscope, the MEMS heart sound sensor can provide the first and second heart sounds containing more abundant information about the lesion. Compared with the 3200-type electronic stethoscope from 3M, it has better performance and lower cost.

[1]  Anup Kumar Gogoi,et al.  Design Issues of Piezoresistive MEMS Accelerometer for an Application Specific Medical Diagnostic System , 2016 .

[2]  Roberto Raiteri,et al.  Micromechanics senses biomolecules , 2002 .

[3]  Jung-Tang Huang,et al.  Study of injection molding pressure sensor with low cost and small probe , 2002 .

[4]  Cheng Hong,et al.  [The invention and evolution of the stethoscope]. , 2010, Zhonghua yi shi za zhi.

[5]  Cao Yan Design of Digital Stethoscope Based on Auscultation Audio Spectrum Analysis , 2013 .

[6]  Tan Jiang-ping Heart sound signal gathering and analyzing , 2004 .

[7]  Andrew A. Goldenberg,et al.  Micromachined 2-D scanner for 3-D optical coherence tomography , 2005 .

[8]  A. B. Hanley,et al.  Use of a flow cell bioreactor as a chronic toxicity model system. , 1999, Toxicology in vitro : an international journal published in association with BIBRA.

[9]  Zhuangde Jiang,et al.  A Novel Piezoresistive Accelerometer with SPBs to Improve the Tradeoff between the Sensitivity and the Resonant Frequency , 2016, Sensors.

[10]  Ulrich Wagner,et al.  Reliability of MEMS - a methodical approach , 2002, Microelectron. Reliab..

[11]  Yilong Hao,et al.  Study of silicon-based MEMS technology and its standard process , 2002 .

[12]  D. T. Barry,et al.  Time-frequency transforms: a new approach to first heart sound frequency dynamics , 1992, IEEE Transactions on Biomedical Engineering.

[13]  Lv Jun-xia Development and Application of Micro Electromechanical System (MEMS) , 2005 .

[14]  M. A. Haque,et al.  Application of MEMS force sensors for in situ mechanical characterization of nano-scale thin films in SEM and TEM , 2002 .

[15]  S. Sugiyama,et al.  Analysis of piezoresistance in p-type silicon for mechanical sensors , 2002 .

[16]  Yu Xiao BioMEMS——bridging of biomedical diagnostics and treatments , 2003 .