Three‐point dixon method enables whole‐body water and fat imaging of obese subjects

Dixon imaging techniques derive chemical shift‐separated water and fat images, enabling the quantification of fat content and forming an alternative to fat suppression. Whole‐body Dixon imaging is of interest in studies of obesity and the metabolic syndrome, and possibly in oncology. A three‐point Dixon method is proposed where two solutions are found analytically in each voxel. The true solution is identified by a multiseed three‐dimensional region‐growing scheme with a dynamic path, allowing confident regions to be solved before unconfident regions, such as background noise. 2π‐Phase unwrapping is not required. Whole‐body datasets (256 × 184 × 252 voxels) were collected from 39 subjects (body mass index 19.8‐45.4 kg/m2), in a mean scan time of 5 min 15 sec. Water and fat images were reconstructed offline, using the proposed method and two reference methods. The resulting images were subjectively graded on a four‐grade scale by two radiologists, blinded to the method used. The proposed method was found superior to the reference methods. It exclusively received the two highest grades, implying that only mild reconstruction failures were found. The computation time for a whole‐body dataset was 1 min 51.5 sec ± 3.0 sec. It was concluded that whole‐body water and fat imaging is feasible even for obese subjects, using the proposed method. Magn Reson Med 63:1659–1668, 2010. © 2010 Wiley‐Liss, Inc.

[1]  Mathews Jacob,et al.  Algebraic Decomposition of Fat and Water in MRI , 2009, IEEE Transactions on Medical Imaging.

[2]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[3]  P Kellman,et al.  Joint estimation of water/fat images and field inhomogeneity map , 2008, Magnetic resonance in medicine.

[4]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[5]  J Szumowski,et al.  Two‐point Dixon technique for water‐fat signal decomposition with B0 inhomogeneity correction , 1997, Magnetic resonance in medicine.

[6]  Norbert J Pelc,et al.  Cramér–Rao bounds for three‐point decomposition of water and fat , 2005, Magnetic resonance in medicine.

[7]  G. Glover Multipoint dixon technique for water and fat proton and susceptibility imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[8]  D W Kormos,et al.  Separation of true fat and water images by correcting magnetic field inhomogeneity in situ. , 1986, Radiology.

[9]  Q. Xiang,et al.  Water‐fat imaging with direct phase encoding , 1997, Journal of magnetic resonance imaging : JMRI.

[10]  G. Gold,et al.  Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging , 2005, Magnetic resonance in medicine.

[11]  Peter Börnert,et al.  Principles of whole‐body continuously‐moving‐table MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[12]  Peter Börnert,et al.  Automated assessment of whole‐body adipose tissue depots from continuously moving bed MRI: A feasibility study , 2009, Journal of magnetic resonance imaging : JMRI.

[13]  Norbert J Pelc,et al.  Field map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition , 2005, Magnetic resonance in medicine.

[14]  Q S Xiang,et al.  Chemical shift imaging with spectrum modeling , 2001, Magnetic resonance in medicine.

[15]  Hans Knutsson,et al.  Phase Sensitive Reconstruction for Water/Fat Separation in MR Imaging Using Inverse Gradient , 2007, MICCAI.

[16]  J Szumowski,et al.  Phase unwrapping in the three-point Dixon method for fat suppression MR imaging. , 1994, Radiology.

[17]  S. Reeder,et al.  Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation , 2007, Journal of magnetic resonance imaging : JMRI.

[18]  S. Reeder,et al.  Multiecho water‐fat separation and simultaneous R  2* estimation with multifrequency fat spectrum modeling , 2008, Magnetic resonance in medicine.

[19]  Wenmiao Lu,et al.  Multiresolution field map estimation using golden section search for water‐fat separation , 2008, Magnetic resonance in medicine.

[20]  S. Reeder,et al.  Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise , 2007, Magnetic resonance in medicine.

[21]  Jingfei Ma,et al.  Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithm , 2004, Magnetic resonance in medicine.

[22]  G H Glover,et al.  Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction , 1991, Magnetic resonance in medicine.

[23]  Michael Markl,et al.  Multicoil Dixon chemical species separation with an iterative least‐squares estimation method , 2004, Magnetic resonance in medicine.

[24]  Qing-San Xiang,et al.  Two‐point water‐fat imaging with partially‐opposed‐phase (POP) acquisition: An asymmetric Dixon method , 2006, Magnetic resonance in medicine.

[25]  Maria A. Schmidt,et al.  Two‐point dixon fat–water separation: Improving reliability and accuracy in phase correction algorithms , 2008, Journal of magnetic resonance imaging : JMRI.

[26]  Jingfei Ma,et al.  Fast dixon‐based multisequence and multiplanar MRI for whole‐body detection of cancer metastases , 2009, Journal of magnetic resonance imaging : JMRI.

[27]  Jingfei Ma Dixon techniques for water and fat imaging , 2008, Journal of magnetic resonance imaging : JMRI.

[28]  B. Aldefeld,et al.  Whole‐body 3D water/fat resolved continuously moving table imaging , 2007, Journal of magnetic resonance imaging : JMRI.