Determination of polychlorinated biphenyls and organochlorine pesticides in small volumes of human blood by high-throughput on-line SPE-LVI-GC-HRMS.

A fully automated and robust method featuring on-line solid-phase extraction (SPE) and large volume injection (LVI) gas chromatographic (GC) high resolution mass spectrometry (HRMS) is used to determine polychlorinated biphenyls (PCBs) and organochlorine pesticides, such as penta- and hexachlorobenzene (PeCBz, HxCBz), hexachlorocyclohexane isomers (HCH) and 4,4'-dichlorodiphenyldichloroethene (a metabolite of dichlorodiphenyltrichloroethane (DDT)), with only 200μl of human blood, serum or plasma. After spiking the sample with (13)C-labeled internal standards and precipitating the proteins, the sample is passed through a 10mm×2.0mm ID SPE cartridge filled with C18 material that adsorbs the analytes. After washing and drying, the cartridge is extracted with hexane/dodecane (99/1, v/v); the extract is directly injected into a LVI where GC/HRMS analysis follows. The fully automated system utilizes a robotic autosampler and a modular SPE system including two high-pressure syringe pumps, an automatic SPE cartridge exchanger unit and 6 switchable valves. All sample preparation steps are performed within 20min during the GC run of a previous sample, limiting the throughput with only the GC runtime. The contents are quantified using the isotope dilution method. Due to laboratory air contamination problems, we achieved LOQs of 0.017 (PeCBz), 0.009 (HxCBz), 0.007 (HCH), 0.016 (DDE), while for the six indicator PCBs, we achieved values of 0.030 (PCB-28), 0.044 (PCB-52), 0.024 (PCB-101), 0.009 (PCB-138), 0.015 (PCB-153) and 0.008 (PCB-180)μg/l serum. Under clean laboratory air conditions, these values may be improved. This method is recommended when high throughput is desirable and/or only small amounts of material are available, such as during studies involving children.

[1]  J. Antignac,et al.  The ion suppression phenomenon in liquid chromatography–mass spectrometry and its consequences in the field of residue analysis , 2005 .

[2]  H. Fromme,et al.  Pilot study on the exposure of the German general population to non-dioxin-like and dioxin-like PCBs. , 2011, International journal of hygiene and environmental health.

[3]  Mohamed Abdel-Rehim,et al.  New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications. I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[4]  Development of a new automated clean-up system for the simultaneous analysis of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and 'dioxin-like' polychlorinated biphenyls (dl-PCB) in flue gas emissions by GPC-SPE. , 2012, Journal of environmental monitoring : JEM.

[5]  B. Buszewski,et al.  Past, Present, and Future of Solid Phase Extraction: A Review , 2012 .

[6]  A. Kočan,et al.  Simple solid-phase extraction method for determination of polychlorinated biphenyls and selected organochlorine pesticides in human serum. , 2005, Journal of chromatography. A.

[7]  M. Abdel-Rehim Recent advances in microextraction by packed sorbent for bioanalysis. , 2010, Journal of chromatography. A.

[8]  Kerstin Becker,et al.  German Environmental Survey 1998 (GerES III): environmental pollutants in blood of the German population. , 2002, International journal of hygiene and environmental health.

[9]  L Ramos,et al.  Miniaturized selective pressurized liquid extraction of polychlorinated biphenyls and polybrominated diphenyl ethers from feedstuffs. , 2013, Journal of chromatography. A.

[10]  R. Ramautar,et al.  Recent developments in coupled SPE‐CE , 2010, Electrophoresis.

[11]  J. Angerer,et al.  Analyses of hazardous substances in biological materials , 1993 .

[12]  E. Millán,et al.  Determination of organochlorine pesticides and polychlorinated biphenyls in human serum using headspace solid-phase microextraction and gas chromatography-electron capture detection. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[13]  Buu N. Tran,et al.  Analysis of polychlorinated biphenyls in human serum by gas chromatography-mass selective detection operating at high ion source temperature. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[14]  M. Abdel-Rehim Microextraction by packed sorbent (MEPS): a tutorial. , 2011, Analytica chimica acta.

[15]  Jean-François Focant,et al.  Semiautomated high-throughput extraction and cleanup method for the measurement of polybrominated diphenyl ethers, polybrominated biphenyls, and polychlorinated biphenyls in human serum. , 2004, Analytical chemistry.

[16]  S. Rhind,et al.  Optimized determination of polybrominated diphenyl ethers and polychlorinated biphenyls in sheep serum by solid-phase extraction-gas chromatography-mass spectrometry. , 2011, Talanta.

[17]  E. De Pauw,et al.  Automated sample preparation-fractionation for the measurement of dioxins and related compounds in biological matrices: a review. , 2004, Talanta.

[18]  Lyn Denison,et al.  Stockholm Convention on Persistent Organic Pollutants , 2013 .

[19]  M. Wilhelm,et al.  PCDD/F and dioxin-like PCB in human blood and milk from German mothers. , 2007, Chemosphere.

[20]  R. Slama,et al.  Birth Weight and Prenatal Exposure to Polychlorinated Biphenyls (PCBs) and Dichlorodiphenyldichloroethylene (DDE): A Meta-analysis within 12 European Birth Cohorts , 2011, Environmental health perspectives.

[21]  B. Gómara,et al.  A simple and fast method for the simultaneous determination of polychlorinated biphenyls and polybrominated diphenyl ethers in small volumes of human serum. , 2007, Journal of chromatography. A.

[22]  E. De Pauw,et al.  High-throughput biomonitoring of dioxins and polychlorinated biphenyls at the sub-picogram level in human serum. , 2006, Journal of chromatography. A.

[23]  S. Ceccatelli,et al.  Single step determination of PCB 126 and 153 in rat tissues by using solid phase microextraction/gas chromatography-mass spectrometry: Comparison with solid phase extraction and liquid/liquid extraction. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[24]  P. Amiano,et al.  Method for the determination of selected organochlorine pesticides and polychlorinated biphenyls in human serum based on a gel permeation chromatographic clean-up. , 2009, Chemosphere.

[25]  T. Göen,et al.  Internal exposure to hazardous substances of persons from various continents: investigations on exposure to different organochlorine compounds , 1997, International archives of occupational and environmental health.

[26]  Jianwen She,et al.  Measurements of polybrominated diphenyl ethers and polychlorinated biphenyls in a single drop of blood. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[27]  T. Annesley Ion suppression in mass spectrometry. , 2003, Clinical chemistry.