The propensity of individuals to deposit DNA and secondary transfer of low level DNA from individuals to inert surfaces.

We have shown that there is a difference between individuals in their tendency to deposit DNA on an item when it is touched. While a good DNA shedder may leave behind a full DNA profile immediately after hand washing, poor DNA shedders may only do so when their hands have not been washed for a period of 6h. We have also demonstrated that transfer of DNA from one individual (A) to another (B) and subsequently to an object is possible under specific laboratory conditions using the AMPFISTR SGM Plus multiplex at both 28 and 34 PCR cycles. This is a form of secondary transfer. If a 30 min or 1h delay was introduced before contact of individual B with the object then at 34 cycles a mixture of profiles from both individuals was recovered. We have also determined that the quantity and quality of DNA profiles recovered is dependent upon the particular individuals involved in the transfer process. The findings reported here are preliminary and further investigations are underway in order to further add to understanding of the issues of DNA transfer and persistence.

[1]  J Buckleton,et al.  Interpreting simple STR mixtures using allele peak areas. , 1998, Forensic science international.

[2]  P Gill,et al.  Application of low copy number DNA profiling. , 2001, Croatian medical journal.

[3]  I. Evett,et al.  A hierarchy of propositions: deciding which level to address in casework , 1998 .

[4]  P. Wiegand,et al.  DNA typing of epithelial cells after strangulation , 1997, International Journal of Legal Medicine.

[5]  David Van Hoofstat,et al.  DNA typing of Fingerprints and Skin Debris: Sensitivity of Capillary Electrophoresis in Forensic Applications using Multiplex PCR , 1998 .

[6]  A. Urquhart,et al.  DNA fingerprinting from single cells , 1997, Nature.

[7]  R. Sparkes,et al.  Validation of the AMPFlSTR SGM plus system for use in forensic casework. , 2000, Forensic science international.

[8]  H. C. Lee,et al.  A systematic analysis of secondary DNA transfer. , 1999, Journal of forensic sciences.

[9]  J Buckleton,et al.  An investigation of the rigor of interpretation rules for STRs derived from less than 100 pg of DNA. , 2000, Forensic science international.

[10]  R. V. Oorschot,et al.  DNA fingerprints from fingerprints , 1997, Nature.

[11]  P Gill,et al.  A comparison of the characteristics of profiles produced with the AMPFlSTR SGM Plus multiplex system for both standard and low copy number (LCN) STR DNA analysis. , 2001, Forensic science international.

[12]  P Taberlet,et al.  Reliable genotyping of samples with very low DNA quantities using PCR. , 1996, Nucleic acids research.

[13]  C. Strom,et al.  Use of nested PCR to identify charred human remains and minute amounts of blood. , 1998, Journal of forensic sciences.