Efficiency of antiscatter grids for flat-detector CT

Flat-panel detector CT (FD-CT) scanners offer large volume coverage, but as a consequence are more susceptible to scatter artifacts than standard clinical CT scanners with smaller cone angles. FD-CT scanners can employ antiscatter grids as a scatter rejection technique. We evaluated three standard fluoroscopic antiscatter grids for two different field sizes with respect to scatter suppression efficiency and image quality improvement. The evaluations included simulations and measurements. Regarding the simulation a hybrid model combining deterministic and Monte Carlo (MC) calculations was used combined with an analytical calculation of grid transmission. The scatter-to-primary ratio (SPR) was measured using an adapted collimator technique in order to validate our simulations. The SPR obtained by simulations and measurements with and without antiscatter grids were in agreement typically within 10%. The employment of a grid does not generally provide a significant improvement of the signal-to-noise ratio (SNR). Antiscatter grids led to a significant reduction of cupping artifacts in all cases. There is a trade-off between the SNR and the reduction of the scatter intensity described by the signal-to-noise improvement factor (SNR(if)). For low- or medium-scatter conditions the increase in noise caused by the reduced primary transmission through the grid has to be compensated by a higher exposure. For high scatter conditions SNR(if) is significantly greater than 1; i.e. a decrease of dose of up to 50% can be reached.

[1]  D R Dance,et al.  The computation of scatter in mammography by Monte Carlo methods. , 1984, Physics in medicine and biology.

[2]  S. Richard,et al.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. , 2005, Medical physics.

[3]  G T Barnes,et al.  Contrast and scatter in x-ray imaging. , 1991, Radiographics : a review publication of the Radiological Society of North America, Inc.

[4]  Ruola Ning,et al.  X-ray scatter correction algorithm for cone beam CT imaging. , 2004, Medical physics.

[5]  P. C. Johns,et al.  Scattered radiation in fan beam imaging systems. , 1982, Medical physics.

[6]  R Fahrig,et al.  Performance of glass fiber antiscatter devices at mammographic energies. , 1994, Medical physics.

[7]  John M Boone,et al.  Grid and slot scan scatter reduction in mammography: comparison by using Monte Carlo techniques. , 2002, Radiology.

[8]  G. Barnes,et al.  Semiempirical model for generating tungsten target x-ray spectra. , 1991, Medical physics.

[9]  W Kalender,et al.  Monte Carlo calculations of x-ray scatter data for diagnostic radiology. , 1981, Physics in medicine and biology.

[10]  W. Kalender,et al.  Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT , 2006, Physics in medicine and biology.

[11]  Nicolai A. Moldovan,et al.  Focused two-dimensional antiscatter grid for mammography , 2002, SPIE Optics + Photonics.

[12]  Horst Aichinger,et al.  Radiation Exposure and Image Quality in X-Ray Diagnostic Radiology , 2004 .

[13]  W A Kalender,et al.  Calculation of x-ray grid characteristics by Monte Carlo methods. , 1982, Physics in medicine and biology.

[14]  H Bernstein,et al.  A detailed experimental and theoretical comparison of the angular and energy dependencies of grid transmission. , 1983, Medical physics.

[15]  Willi A Kalender,et al.  X-ray scatter data for flat-panel detector CT. , 2007, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[16]  K P Maher,et al.  Comparison of scatter measurement techniques in digital fluoroscopy , 1993 .

[17]  U Neitzel,et al.  Grids or air gaps for scatter reduction in digital radiography: a model calculation. , 1992, Medical physics.

[18]  K L Lam,et al.  Studies of performance of antiscatter grids in digital radiography: effect on signal-to-noise ratio. , 1990, Medical physics.

[19]  Lei Zhu,et al.  Scatter Correction Method for X-Ray CT Using Primary Modulation: Theory and Preliminary Results , 2006, IEEE Transactions on Medical Imaging.

[20]  Y Higashida,et al.  Performance of antiscatter grids in diagnostic radiology: experimental measurements and Monte Carlo simulation studies. , 1985, Medical physics.

[21]  D. Jaffray,et al.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.