Performance of Loop-Mediated Isothermal Amplification for the Identification of Submicroscopic Plasmodium falciparum Infection in Uganda.

Accurately identifying and targeting the human reservoir of malaria parasitemia is critical for malaria control, and requires a reliable and sensitive diagnostic method. Loop-mediated isothermal amplification (LAMP) is increasingly used to diagnose submicroscopic parasitemia. Although most published studies report the sensitivity of LAMP compared with nested polymerase chain reaction (PCR) as ≥ 80%, they have failed to use a consistent, sensitive diagnostic as a comparator. We used cross-sectional samples from children and adults in Tororo, Uganda, a region with high but declining transmission due to indoor residual spraying, to characterize the sensitivity and specificity of pan-Plasmodium LAMP for detecting submicroscopic infections. We compared LAMP results targeting a mitochondrial DNA sequence conserved in all Plasmodium species, performed on DNA extracted from dried blood spots, to those of a gold standard quantitative PCR assay targeting the var gene acidic terminal sequence of Plasmodium falciparum (varATS qPCR), performed on DNA extracted from 200 µL of whole blood. Using LAMP and varATS qPCR increased the detection of parasitemia 2- to 5-fold, compared with microscopy. Among microscopy-negative samples, the sensitivity of LAMP was 81.5% for detecting infection ≥ 1 parasites/µL. However, low density infections were common, and LAMP failed to identify more than half of all infections diagnosed by varATS qPCR, performing with an overall sensitivity of 44.7% for detecting submicroscopic infections ≥ 0.01 parasites/µL. Thus, although the LAMP assay is more sensitive than microscopy, it missed a significant portion of the submicroscopic reservoir. These findings have important implications for malaria control, particularly in settings where low-density infections predominate.

[1]  H. Lamadrid-Figueroa,et al.  Assessing the effect of indoor residual spraying (IRS) on malaria morbidity in Northern Uganda: a before and after study , 2017, Malaria Journal.

[2]  J. Gomis,et al.  Evidence of non-Plasmodium falciparum malaria infection in Kédougou, Sénégal , 2017, Malaria Journal.

[3]  Katia Charland,et al.  Measures of Malaria Burden after Long-Lasting Insecticidal Net Distribution and Indoor Residual Spraying at Three Sites in Uganda: A Prospective Observational Study , 2016, PLoS medicine.

[4]  David L. Smith,et al.  Characterizing microscopic and submicroscopic malaria parasitaemia at three sites with varied transmission intensity in Uganda , 2016, Malaria Journal.

[5]  S. Parikh,et al.  Asymptomatic Plasmodium Infections in Children in Low Malaria Transmission Setting, Southwestern Uganda , 2016, Emerging infectious diseases.

[6]  S. Meshnick,et al.  Microscopic Plasmodium falciparum Gametocytemia and Infectivity to Mosquitoes in Cambodia. , 2016, The Journal of infectious diseases.

[7]  O. Doumbo,et al.  Non-falciparum malaria infections in pregnant women in West Africa , 2016, Malaria Journal.

[8]  Hannah C. Slater,et al.  Comparison of diagnostics for the detection of asymptomatic Plasmodium falciparum infections to inform control and elimination strategies , 2015, Nature.

[9]  L. Rénia,et al.  The epidemiology of subclinical malaria infections in South-East Asia: findings from cross-sectional surveys in Thailand–Myanmar border areas, Cambodia, and Vietnam , 2015, Malaria Journal.

[10]  Andrew J Tatem,et al.  Malaria transmission, infection, and disease at three sites with varied transmission intensity in Uganda: implications for malaria control. , 2015, The American journal of tropical medicine and hygiene.

[11]  P. Rosenthal,et al.  The Effect of Storage and Extraction Methods on Amplification of Plasmodium falciparum DNA from Dried Blood Spots. , 2015, The American journal of tropical medicine and hygiene.

[12]  L. Konaté,et al.  Infectiousness of the human population to Anopheles arabiensis by direct skin feeding in an area hypoendemic for malaria in Senegal. , 2015, The American journal of tropical medicine and hygiene.

[13]  L. Robinson,et al.  Ultra-Sensitive Detection of Plasmodium falciparum by Amplification of Multi-Copy Subtelomeric Targets , 2015, PLoS medicine.

[14]  Abdullah S. Ali,et al.  Loop-mediated isothermal amplification (LAMP) for point-of-care detection of asymptomatic low-density malaria parasite carriers in Zanzibar , 2015, Malaria Journal.

[15]  V. A. Stewart,et al.  Characterization of Plasmodium ovale curtisi and P. ovale wallikeri in Western Kenya Utilizing a Novel Species-specific Real-time PCR Assay , 2015, PLoS neglected tropical diseases.

[16]  Nora L. Martínez,et al.  Evaluation of the Loop Mediated Isothermal DNA Amplification (LAMP) Kit for Malaria Diagnosis in P. vivax Endemic Settings of Colombia , 2015, PLoS neglected tropical diseases.

[17]  U. d’Alessandro,et al.  Molecular-based isothermal tests for field diagnosis of malaria and their potential contribution to malaria elimination , 2014, The Journal of antimicrobial chemotherapy.

[18]  I. González,et al.  Loop Mediated Isothermal Amplification (LAMP) Accurately Detects Malaria DNA from Filter Paper Blood Samples of Low Density Parasitaemias , 2014, PloS one.

[19]  G. Dorsey,et al.  The effect of indoor residual spraying on malaria and anemia in a high-transmission area of northern Uganda. , 2013, The American journal of tropical medicine and hygiene.

[20]  Colin J. Sutherland,et al.  Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda , 2013, The Journal of infectious diseases.

[21]  M. Perkins,et al.  Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria , 2013, The Journal of infectious diseases.

[22]  André Tiaden,et al.  The Dynamics of Natural Plasmodium falciparum Infections , 2012, PloS one.

[23]  O. Doumbo,et al.  Mosquito Feeding Assays to Determine the Infectiousness of Naturally Infected Plasmodium falciparum Gametocyte Carriers , 2012, PloS one.

[24]  G. Dorsey,et al.  PCR-Based Pooling of Dried Blood Spots for Detection of Malaria Parasites: Optimization and Application to a Cohort of Ugandan Children , 2010, Journal of Clinical Microbiology.

[25]  O. Thekisoe,et al.  Comparative diagnosis of malaria infections by microscopy, nested PCR, and LAMP in northern Thailand. , 2010, The American journal of tropical medicine and hygiene.

[26]  Colin J. Sutherland,et al.  Mitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal Amplification , 2010, Journal of Clinical Microbiology.

[27]  K. Silamut,et al.  Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria. , 2007, The American journal of tropical medicine and hygiene.

[28]  Eun-Taek Han,et al.  Detection of Four Plasmodium Species by Genus- and Species-Specific Loop-Mediated Isothermal Amplification for Clinical Diagnosis , 2007, Journal of Clinical Microbiology.

[29]  Umberto D'Alessandro,et al.  Variation in malaria transmission intensity in seven sites throughout Uganda. , 2006, The American journal of tropical medicine and hygiene.

[30]  O. Doumbo,et al.  Pyrimethamine and proguanil resistance-conferring mutations in Plasmodium falciparum dihydrofolate reductase: polymerase chain reaction methods for surveillance in Africa. , 1995, The American journal of tropical medicine and hygiene.

[31]  T. Bousema,et al.  Dynamics of the Human Infectious Reservoir for Malaria Determined by Mosquito Feeding Assays and Ultrasensitive Malaria Diagnosis in Burkina Faso. , 2016, The Journal of infectious diseases.

[32]  J. Meunier,et al.  Estimation of malaria transmission from humans to mosquitoes in two neighbouring villages in south Cameroon: evaluation and comparison of several indices. , 2003, Transactions of the Royal Society of Tropical Medicine and Hygiene.