Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented.
[1]
J. Douse.
Improved method for the trace analysis of explosives by silica capillary column gas chromatography with thermal energy analysis detection
,
1987
.
[2]
J.M.F. Douse,et al.
Trace analysis of explosives at the low nanogram level in handswab extracts using columns of amberlite xad-7 porous polymmer beads and silica capillary column gas chromatography with thermal energy analysis and electron-capture detection
,
1985
.
[3]
S. D. Harvey,et al.
Analysis of the explosive 2,4,6-trinitrophenylmethylnitramine (tetryl) in bush bean plants
,
1993
.
[4]
D. Lubman,et al.
Detection of liquid injection using an atmospheric pressure ionization radiofrequency plasma source.
,
1993,
Analytical chemistry.
[5]
D. A. Collins.
Modification to a thermal energy analyzer with associated electronic filtering for improved gas chromatographic analysis of explosives traces
,
1989
.
[6]
Peter Kolla,et al.
Trace Analysis of Explosives from Complex Mixtures with Sample Pretreatment and Selective Detection
,
1991
.
[7]
Richard E. Tontarski,et al.
Improved Determination of Nitrotoluenes Using Liquid Chromatography with Photolytically Assisted Thermal Energy Analysis (LC-PAT)
,
1987
.
[8]
D. Fine,et al.
Picogram Analyses of Explosive Residues Using the Thermal Energy Analyzer (TEA
,
1984
.
[9]
K. Cammann,et al.
Determination of explosives residues in soils by micellar electrokinetic capillary chromatography and high performance liquid chromatography A comparative study
,
1993
.
[10]
R. Voyksner,et al.
Negative ion formation in electrospray mass spectrometry
,
1993,
Journal of the American Society for Mass Spectrometry.
[11]
Reinhard Bredehorst,et al.
Continuous-flow immunosensor for detection of explosives
,
1993
.