Study of Corona Discharge Pattern on High Voltage Transmission Lines for Inspecting Faulty Porcelain Insulators

The corona pattern from porcelain insulator strings on high voltage (HV) transmission lines has been investigated for inspecting faulty insulators on-line. Corona patterns from HV conductive line, metal accessory, and discharge patterns from bad connection, power stations, have also been studied for background pulse noise elimination. A pattern recognition method for inspecting faulty porcelain insulators is proposed, which consists of several criteria. It is found that the harmonics and carriers from the transmission lines influence the recognition seriously, which can be eliminated by choosing a high frequency band of sensors (2 MHz-20 MHz). Based on the above investigations, an instrument was developed and used on the field measurements in Lanzhou and Zhengzhou power utilities in China. The field results show a strong support for this method. On the measurement of 76 towers, the measuring accuracy of inspecting faulty insulators was about 87.5%.

[1]  Wen Yuanfang,et al.  Investigation on characteristics of corona current to single insulator , 2001, Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Ele.

[2]  L.E. Lundgaard,et al.  Partial discharge. XIV. Acoustic partial discharge detection-practical application , 1992, IEEE Electrical Insulation Magazine.

[3]  Lijian Ding,et al.  Online detecting insulator corona for diagnosing faulty insulators on transmission line , 2001, 2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225).

[4]  G. H. Vaillancourt,et al.  New live line tester for porcelain suspension insulators on high-voltage power lines , 1994 .

[5]  Yang Chun Cheng,et al.  A technique of detecting faulty insulator strings on ground , 1999 .

[6]  Cheng Rong Li,et al.  The sensitivity of identify faulty insulator string by detecting insulator corona current , 1998, Proceedings of 1998 International Symposium on Electrical Insulating Materials. 1998 Asian International Conference on Dielectrics and Electrical Insulation. 30th Symposium on Electrical Insulating Ma.

[7]  S. Carignan,et al.  Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement method , 1998 .

[8]  Xianggen Yin,et al.  The study of the corona current characteristics of transmission line insulators , 2001, Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Ele.

[9]  Qian Shi,et al.  Identifying faulty insulator strings by detecting insulator corona pulse current , 1998, POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151).