Accuracy of quantitative reconstructions in SPECT/CT imaging
暂无分享,去创建一个
S Shcherbinin | A Celler | A. Celler | R. Vanderwerf | A. Driedger | S. Shcherbinin | T. Belhocine | T Belhocine | R Vanderwerf | A Driedger
[1] Lefteris Livieratos,et al. A dual modality approach to quantitative quality control in emission tomography , 2005, Physics in medicine and biology.
[2] Tracy L. Faber,et al. Automated quality control of emission-transmission misalignment for attenuation correction in myocardial perfusion imaging with SPECT-CT systems , 2005 .
[3] Habib Zaidi,et al. Determination of the attenuation map in emission tomography. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[4] William C. Barber,et al. Dual-Modality Imaging of Cancer with SPECT/CT , 2002, Technology in cancer research & treatment.
[5] K. Cranley,et al. Correction for deadtime losses in a gamma camera/data analysis system , 2004, European Journal of Nuclear Medicine.
[6] Dale L. Bailey,et al. Development of a cost-effective modular SPECT/CT scanner , 2007, European Journal of Nuclear Medicine and Molecular Imaging.
[7] Arik Wolak,et al. Quantitative myocardial-perfusion SPECT: Comparison of three state-of-the-art software packages , 2007, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[8] A scatter model for parallel and converging beam SPECT based on the Klein-Nishina formula , 1994 .
[9] Michael A. King,et al. CHAPTER 22 – Attenuation, Scatter, and Spatial Resolution Compensation in SPECT , 2004 .
[10] Tracy L Faber,et al. Automated quality control of emission-transmission misalignment for attenuation correction in myocardial perfusion imaging with SPECT-CT systems. , 2006, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[11] E. Veklerov,et al. MLE reconstruction of a brain phantom using a Monte Carlo transition matrix and a statistical stopping rule , 1988 .
[12] Stephan Blinder,et al. Experimental verification of 3D detector response compensation using the OSEM reconstruction method , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).
[13] R. K. Wu,et al. Absolute quantitation of radioactivity using the buildup factor. , 1984, Medical physics.
[14] Oliver Lindner,et al. A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT Introduced by misalignment between emission scan and CT-derived attenuation maps. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[15] Eric C Frey,et al. Model-based compensation for quantitative 123I brain SPECT imaging , 2006, Physics in medicine and biology.
[16] Matt A. King,et al. SPECT volume quantitation: influence of spatial resolution, source size and shape, and voxel size. , 1991, Medical physics.
[17] B. H. Hasegawa,et al. Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment , 1995 .
[18] P. Msaki,et al. Subtraction of Compton-scattered photons in single-photon emission computerized tomography. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[19] K. Koral,et al. Recovery of total I-131 activity within focal volumes using SPECT and 3D OSEM , 2007, Physics in medicine and biology.
[20] A method for calibrating the CT-based attenuation correction of PET in human tissue , 2006 .
[21] H. Zaidi,et al. Dual-Modality Imaging: More Than the Sum of its Components , 2006 .
[22] Michael A. King,et al. Quantitative myocardial perfusion SPECT , 1998, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[23] R. G. Wells,et al. Analytical calculation of scatter distributions in SPECT projections , 1995 .
[24] I Buvat,et al. Validation of the Monte Carlo simulator GATE for indium-111 imaging , 2005, Physics in medicine and biology.
[25] I. Buvat,et al. Respective importance of scatter, attenuation, collimator response and partial volume effect corrections for accurate quantification in /sup 123/I dopamine receptor imaging , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).
[26] D. Bailey,et al. Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[27] R. Jaszczak,et al. Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECT , 1985, IEEE Transactions on Nuclear Science.
[28] H. Zaidi,et al. Scatter Correction Strategies in Emission Tomography , 2006 .
[29] Irene Buvat,et al. Quantification in emission tomography: Challenges, solutions, and performance , 2007 .
[30] Andrea Varrone,et al. Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[31] D. Faul,et al. A method for calibrating the CT-based attenuation correction of PET in human tissue , 2004, IEEE Transactions on Nuclear Science.
[32] T. Turkington,et al. Volume and activity quantitation with iodine-123 SPECT. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[33] G. Gullberg,et al. A slice-by-slice blurring model and kernel evaluation using the Klein-Nishina formula for 3D scatter compensation in parallel and converging beam SPECT. , 2000, Physics in medicine and biology.
[34] G. Zeng,et al. A projector/backprojector with slice-to-slice blurring for efficient three-dimensional scatter modeling , 1999, IEEE Transactions on Medical Imaging.
[35] Ronald J. Jaszczak,et al. Physical Factors Affecting Quantitative Measurements Using Camera-Based Single Photon Emission Computed Tomography (Spect) , 1981, IEEE Transactions on Nuclear Science.
[36] C E Floyd,et al. Nonisotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[37] S. Blinder,et al. Implementation of an analytically based scatter correction in SPECT reconstructions , 2003, IEEE Transactions on Nuclear Science.
[38] I. Buvat,et al. Relative impact of scatter, attenuation, collimator response and finite spatial resolution corrections in cardiac SPECT , 2000 .
[39] Klaus Bacher,et al. Patient dosimetry in radionuclide therapy: the whys and the wherefores , 2005, Nuclear medicine communications.
[40] T A Riauka,et al. Photon propagation and detection in single-photon emission computed tomography--an analytical approach. , 1994, Medical physics.
[41] J E Bowsher,et al. Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[42] Eric C Frey,et al. A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT , 2005, Physics in medicine and biology.
[43] D. Bailey,et al. A transmission-dependent method for scatter correction in SPECT. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[44] Anna Celler,et al. Implementation of an iterative scatter correction, the influence of attenuation map quality and their effect on absolute quantitation in SPECT , 2007, Physics in medicine and biology.
[45] A. Celler,et al. Improved numerical integration for analytical photon distribution calculation in SPECT , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.
[46] Freek J Beekman,et al. Hybrid scatter correction applied to quantitative holmium-166 SPECT , 2006, Physics in medicine and biology.
[47] I Buvat,et al. Fully 3D Monte Carlo reconstruction in SPECT: a feasibility study , 2005, Physics in medicine and biology.
[48] Lee-Tzuu Chang,et al. A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.
[49] M Ljungberg,et al. Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a monte Carlo study. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[50] Michael Lassmann,et al. The impact of PET and SPECT on dosimetry for targeted radionuclide therapy. , 2006, Zeitschrift fur medizinische Physik.
[51] B. Tsui,et al. A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.