Characteristic Analysis of Subsynchronous Resonance in Practical Wind Farms Connected to Series-Compensated Transmissions

The emerging subsynchronous resonance (SSR) caused by the interaction of wind turbine generators (WTGs) with series compensation has aroused great concerns. For this particular issue, this paper is aimed to fill the gap between theoretical studies and actual observations. By analyzing the field data of 58 SSR events captured in a practical wind power system and examining the observed dynamics with previous theoretical results, the mechanism and characteristics of SSR are revealed in a more explicit and substantial way. The necessary conditions and dominant influential factors are identified and the underlying reasons are discovered. Theoretically derived as well as practically measured impedance models have demonstrated that the converter control of doubly fed induction generator (DFIG) produces negative resistance at the slip frequency and thus causes unstable SSR; while permanent magnet synchronous generators and self-excited induction generators are just passively engaged in those SSR incidents. The distribution of the oscillation frequency has also been examined with field measurements. It is discovered that WTGs at different locations participate into the same SSR mode and their frequencies are not fixed but keep changing with the time, the variation of grid topology, and the number of online generators.

[1]  Shun-Hsien Huang,et al.  ERCOT experience with Sub-synchronous Control Interaction and proposed remediation , 2012, PES T&D 2012.

[2]  Yunzhi Cheng,et al.  Reactance Scan Crossover-Based Approach for Investigating SSCI Concerns for DFIG-Based Wind Turbines , 2013, IEEE Transactions on Power Delivery.

[3]  M.S. El-Moursi,et al.  Novel STATCOM Controller for Mitigating SSR and Damping Power System Oscillations in a Series Compensated Wind Park , 2010, IEEE Transactions on Power Electronics.

[4]  A. Yazdani,et al.  Modeling and Stability Analysis of a DFIG-Based Wind-Power Generator Interfaced With a Series-Compensated Line , 2009, IEEE Transactions on Power Delivery.

[5]  Liang Wang,et al.  Development and Field Experiments of a Generator Terminal Subsynchronous Damper , 2014, IEEE Transactions on Power Electronics.

[6]  Lingling Fan,et al.  Control and analysis of DFIG-based wind turbines in a series compensated network for SSR damping , 2010, IEEE PES General Meeting.

[7]  Frede Blaabjerg,et al.  Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[8]  Roberto Cárdenas,et al.  Control of a Doubly Fed Induction Generator via an Indirect Matrix Converter With Changing DC Voltage , 2011, IEEE Transactions on Industrial Electronics.

[9]  Zhixin Miao,et al.  Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network , 2012, IEEE Transactions on Energy Conversion.

[10]  Bin Wu,et al.  Unified Power Control for PMSG-Based WECS Operating Under Different Grid Conditions , 2011, IEEE Transactions on Energy Conversion.

[11]  Garth D. Irwin,et al.  Sub-synchronous control interactions between type 3 wind turbines and series compensated AC transmission systems , 2011, 2011 IEEE Power and Energy Society General Meeting.

[12]  Keyue Smedley,et al.  Minimizing the Circulation Current in Hexagram Medium-Voltage Variable-Speed Drive by Coupled Inductors , 2011, IEEE Transactions on Industrial Electronics.

[13]  Lingling Fan,et al.  Modal Analysis of a DFIG-Based Wind Farm Interfaced With a Series Compensated Network , 2011, IEEE Transactions on Energy Conversion.

[14]  Rajiv K. Varma,et al.  SSR Alleviation by STATCOM in Induction-Generator-Based Wind Farm Connected to Series Compensated Line , 2014, IEEE Transactions on Sustainable Energy.

[15]  D. Nazarpour,et al.  SSR suppression via STATCOM in series compensated wind farm integrations , 2011, 2011 19th Iranian Conference on Electrical Engineering.

[16]  P. Rodriguez,et al.  Design and Analysis of a Slope Voltage Control for a DFIG Wind Power Plant , 2012, IEEE Transactions on Energy Conversion.

[17]  Xu Yang,et al.  Wind Speed and Rotor Position Sensorless Control for Direct-Drive PMG Wind Turbines , 2010, IEEE Transactions on Industry Applications.

[18]  Jean Mahseredjian,et al.  Coordinated Control of Wind Energy Conversion Systems for Mitigating Subsynchronous Interaction in DFIG-Based Wind Farms , 2014, IEEE Transactions on Smart Grid.

[19]  Lingling Fan,et al.  Modeling of DFIG-Based Wind Farms for SSR Analysis , 2010, IEEE Transactions on Power Delivery.

[20]  Jorge A. Solsona,et al.  Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines , 2015, IEEE Transactions on Power Systems.

[21]  Jiabing Hu,et al.  Effect of reactive power control on stability of DC-link voltage control in VSC connected to weak grid , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[22]  Dehong Xu,et al.  Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator , 2012, IEEE Transactions on Power Electronics.

[23]  R.K. Varma,et al.  Mitigation of Subsynchronous Resonance in a Series-Compensated Wind Farm Using FACTS Controllers , 2008, IEEE Transactions on Power Delivery.

[24]  Lingling Fan,et al.  Mitigating SSR Using DFIG-Based Wind Generation , 2012, IEEE Transactions on Sustainable Energy.

[25]  H. T. Ma,et al.  Sub-Synchronous Control Interaction studies between full-converter wind turbines and series-compensated AC transmission lines , 2012, 2012 IEEE Power and Energy Society General Meeting.

[26]  Rajiv K. Varma,et al.  Subsynchronous resonance in single-cage self-excited-induction-generator-based wind farm connected to series-compensated lines , 2011 .

[27]  Liang Wang,et al.  Investigation of SSR in Practical DFIG-Based Wind Farms Connected to a Series-Compensated Power System , 2015, IEEE Transactions on Power Systems.

[28]  Yong Kang,et al.  A Novel DC Capacitor Voltage Balance Control Method for Cascade Multilevel STATCOM , 2012, IEEE Transactions on Power Electronics.

[29]  D. Woodford,et al.  Simulation requirements for analysis and mitigation of SSCI phenomena in wind farms , 2012, PES T&D 2012.

[30]  Udaya Annakkage,et al.  A procedure to study sub-synchronous interactions in wind integrated power systems , 2013, PES 2013.

[31]  R. Midence,et al.  New microprocessor based relay to monitor and protect power systems against sub-harmonics , 2011, 2011 IEEE Electrical Power and Energy Conference.

[32]  Countermeasures to Subsynchronous Resonance Problems , 1980, IEEE Transactions on Power Apparatus and Systems.

[33]  Mohit Singh,et al.  Doubly fed induction generator in an offshore wind power plant operated at rated V/Hz , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[34]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[35]  Jin Zhong,et al.  Challenges Ahead: Currents Status and Future Prospects for Chinese Energy , 2012, IEEE Power and Energy Magazine.

[36]  Hui Liu,et al.  Quantitative SSR Analysis of Series-Compensated DFIG-Based Wind Farms Using Aggregated RLC Circuit Model , 2017, IEEE Transactions on Power Systems.

[37]  U. D. Annakkage,et al.  Application of an SVC to damp sub-synchronous interaction between wind farms and series compensated transmission lines , 2012, 2012 IEEE Power and Energy Society General Meeting.