Effects of current ripple on dead-time distortion in three-phase voltage source inverters

Inverter dead-time distortion in output voltages have been widely investigated in the past for three-phase PWM voltage source inverters. Also, there have been some studies about multi-phase inverters with reference to multi-phase drives. Usually, almost sinusoidal output currents are considered, with a single zero crossing for every half fundamental period. High output current ripple introduces multiple zero crossing, leading to modified output voltage distortions. In this paper the effect of the output current ripple has been taken into account, in the case of carrier-based PWM techniques when no any dead-time compensation technique is applied. In particular, the harmonic spectrum of the output voltage distortion has been evaluated on the basis of the multiple zero crossing time interval of output currents. In case of relevant current ripple it is verified a relevant deviation of output voltage harmonics in comparison to the case of almost sinusoidal currents. Theoretical analysis has shown that particular low-order harmonics are affected by the current ripple amplitude, and simulation results confirm the developed analytical approach.

[1]  K. Kamiyama,et al.  Fully digital, vector-controlled PWM VSI-fed AC drives with an inverter dead-time compensation strategy , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[2]  M. Jones,et al.  Analysis of Output Current Ripple rms in Multiphase Drives Using Space Vector Approach , 2009, IEEE Transactions on Power Electronics.

[3]  Ping Wang,et al.  Dead-time compensation for VSI based power supply with small filter inductor , 2009, 2009 IEEE 6th International Power Electronics and Motion Control Conference.

[4]  Fang Zheng Peng,et al.  Dead-Time Elimination for Voltage Source Inverters , 2008, IEEE Transactions on Power Electronics.

[5]  Seung-Gi Jeong,et al.  The analysis and compensation of dead-time effects in PWM inverters , 1991 .

[6]  Seon-Hwan Hwang,et al.  Dead Time Compensation Method for Voltage-Fed PWM Inverter , 2010, IEEE Transactions on Energy Conversion.

[7]  Kouki Matsuse,et al.  Analysis and compensation method of voltage error by dead-time with five-leg inverter for two-AC motor independent drives , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[8]  Hamid A. Toliyat,et al.  Multiphase induction motor drives - : a technology status review , 2007 .

[9]  Gabriele Grandi,et al.  Analysis of dead-time effects in multi-phase voltage source inverters , 2012 .

[10]  Russel J. Kerkman,et al.  Pulse based dead time compensator for PWM voltage inverters , 1995, Proceedings of IECON '95 - 21st Annual Conference on IEEE Industrial Electronics.

[11]  M. Jones,et al.  Dead-time effects in voltage source inverter fed multi-phase AC motor drives and their compensation , 2009, 2009 13th European Conference on Power Electronics and Applications.

[12]  T.A. Lipo,et al.  On-line dead time compensation technique for open-loop PWM-VSI drives , 1998, APEC '98 Thirteenth Annual Applied Power Electronics Conference and Exposition.