Computer-Assisted Preoperative Planning for Reduction of Proximal Femoral Fracture Using 3-D-CT Data

This paper describes procedures for repositioning calculations of fractured bone fragments using 3-D-computed tomography (CT), aimed at preoperative planning for computer-guided fracture reduction of the proximal femur. Fracture boundaries of the bone fragments, as ldquofracture lines (FLs),rdquo and the mirror-transformed contralateral femur shape extracted from 3-D-CT were used for repositioning of the fragments. We first describe a method for extracting FLs based on 3-D curvature analysis and then formulate repositioning methods based on registration of bone fragments using the following three constraints: 1) contralateral (CL) femur shape; 2) FLs; and 3) both CL femur shape and fracture lines, as ldquoboth constraintsrdquo. We performed experiments using CT datasets from five simulated and four real patients with proximal femoral fracture. We evaluated the rotation error in reposition calculations and the contact ratio between repositioned fragment boundaries, which are crucial for the recovery of proper functional axes and bone adhesion of fragments, respectively. Experimental results showed that good accuracy and stability were attainable when registration using both constraints was performed after registration using the fracture-line constraint. On average, 6.0deg plusmn0.8deg in rotation error and 89% plusmn 3% in contact ratio were obtained without providing precise initial values.

[1]  G A Brown,et al.  Computed Tomography Image Guided Surgery in Complex Acetabular Fractures , 2000, Clinical orthopaedics and related research.

[2]  A. Gray,et al.  Modern Differential Geometry of Curves and Surfaces with Mathematica, Third Edition (Studies in Advanced Mathematics) , 2006 .

[3]  Stephen R. Aylward,et al.  Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction , 2002, IEEE Transactions on Medical Imaging.

[4]  Wolfgang Birkfellner,et al.  LORENZ: a system for planning long-bone fracture reduction , 2003, SPIE Medical Imaging.

[5]  Naoto Endo,et al.  Report on the Japanese Orthopaedic Association’s 3-year project observing hip fractures at fixed-point hospitals , 2006, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[6]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[7]  Yoon Hyuk Kim,et al.  Kinematic simulation of fracture reduction and bone deformity correction under unilateral external fixation. , 2002, Journal of biomechanics.

[8]  Ivo A. M. J. Broeders,et al.  Internal Fixation of Femoral Neck Fractures with Computer Assisted Surgery , 2003, European Journal of Trauma.

[9]  Lutz-Peter Nolte,et al.  Virtual 3D planning of acetabular fracture reduction , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  Guoyan Zheng,et al.  Automated Detection and Segmentation of Diaphyseal Bone Fragments From Registered C-Arm Images for Long Bone Fracture Reduction , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[11]  J. Lewis,et al.  Dislocations after total hip-replacement arthroplasties. , 1978, The Journal of bone and joint surgery. American volume.

[12]  S. Cummings,et al.  Epidemiology and predictors of fractures associated with osteoporosis. , 1997, The American journal of medicine.

[13]  S. Mukherjee,et al.  Surgeon-instructed , Image-guided and Robot-assisted Long Bone Fractures Reduction , 2005 .

[14]  Mamoru Mitsuishi,et al.  Development of a femur fracture reduction robot , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[15]  K Bouazza-Marouf,et al.  Robotic-assisted internal fixation of hip fractures: A fluoroscopy-based intraoperative registration technique , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[16]  Hideki Yoshikawa,et al.  Computer-assisted fracture reduction of proximal femur using preoperative CT data and intraoperative fluoroscopic images , 2004, CARS.

[17]  R. Sablatnig,et al.  3D Puzzling of Archaeological Fragments∗ , 2004 .

[18]  Mia Hubert,et al.  Robust regression with both continuous and binary regressors , 1997 .

[19]  L. Joskowicz,et al.  FRACAS: a system for computer-aided image-guided long bone fracture surgery. , 1998, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[20]  Guido Gerig,et al.  Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images , 1998, Medical Image Anal..

[21]  James A. Johnson,et al.  Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods. , 2007, Journal of shoulder and elbow surgery.

[22]  Frank Langlotz,et al.  Evaluating partial surface matching for fracture reduction assessment , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..

[23]  Jorge Stolfi,et al.  A Multiscale Method for the Reassembly of Two-Dimensional Fragmented Objects , 2002, IEEE Trans. Pattern Anal. Mach. Intell..

[24]  T. Howe,et al.  The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures--The experience in Singapore. , 2006, Injury.

[25]  Michael J Gardner,et al.  Computer Navigation Allows for Accurate Reduction of Femoral Fractures , 2007, Clinical orthopaedics and related research.

[26]  A. Gray Modern Differential Geometry of Curves and Surfaces , 1993 .